3
List of Illustrations
Figure
Page
1
Front view of PowerVac
®
breaker with front cover ................... 6
2
Rating interference plate........................................................... 6
3
Front view of PowerVac breaker without front cover ................ 8
4
Manual charging........................................................................ 9
5
Gag plate installation ................................................................. 10
6
Operating rod assembly ............................................................ 10
7
Contact gap ............................................................................... 11
8
Breaker turned on right side...................................................... 11
9
Close coil plunger gap ............................................................... 12
10 Trip coil plunger gap .................................................................. 12
11 Control switches ....................................................................... 13
12 Sample operating speed graphs................................................ 19
13 Contact gap adjustment ............................................................ 20
14 Auxiliary switch position ............................................................ 22
15 Spring discharge interlock ......................................................... 24
16 Toggle linkage positions of the ML-18 mechanism ................... 25
17 Schematic of ML-18 mechanism............................................... 27
18 Typical wiring diagram for ML-18 mechanism ........................... 29
19 PowerVac
®
breaker left-front view ............................................ 30
20 PowerVac
®
breaker right-rear view ........................................... 30
21 Trip coil and linkage................................................................... 31
22 Close coil linkage....................................................................... 32
23 Bottom view of the ML-18 mechanism..................................... 33
24 Flex cable connections .............................................................. 34
25 Negative interlock ..................................................................... 34
26 Close latch stop......................................................................... 35
27 Wipe spring............................................................................... 35
Table
Page
1
Control Device and Voltage..................................................... 18
2
Measurements ....................................................................... 36
3
Adjustments............................................................................ 36
THESE INSTRUCTIONS ARE INTENDED FOR USE BY QUALIFIED PERSONNEL FOR INSTRUCTION AND MAINTENANCE PURPOSES.
REPRODUCTION IN WHOLE OR IN PART IS NOT PERMITTED WITHOUT THE EXPRESS PERMISSION OF GENERAL ELECTRIC.
Summary of Contents for PowerVac GEK-86132G
Page 26: ...26 C Breaker closed spring discharged D Breaker closed spring charged Figure 16 Continued ...
Page 28: ...28 Figure 17 Continued ...
Page 29: ...29 Figure 18 Typical wiring diagram for ML 18 and ML 18H mechanisms ...
Page 38: ...Intentionally Left Blank ...
Page 41: ...Notes ...
Page 42: ...Notes ...
Page 43: ...Intentionally Left Blank ...