To remove the water valve assembly:
1. Remove the machine compartment cover. (See
Machine Compartment Cover
.)
2. Remove the icemaker inlet tube.
3. Remove the 1/2-in. hex nut from the water
supply tube. Pull out the tube from the icemaker
valve assembly.
4. Disconnect
the
fl
ow meter wire harness.
5. Remove the Phillips-head screw that holds the
water valve in place. Pull the valve assembly
straight out.
6. Disconnect the water valve wire harness.
7. Remove the dispenser tank water inlet tube
from the water valve assembly.
Icemaker Inlet Tube
Hex Nut
Disconnect
Disconnect
Dispenser Tank
Inlet Tube
To remove the fl ow meter:
1. Remove the water valve assembly. (See
Water
Valve Assembly
.)
2. Remove the 4 Phillips-head screws and the
bracket from the water valve.
3. Remove the John Guest clip. Pull the
fl
ow meter
from the water valve.
Clip
Bracket
Flow Meter
Flow Meter
Hall Sensor