6-40
G650 Generator Protection & Control System
GEK-113285A
6.4 INPUTS / OUTPUTS
6 ACTUAL VALUES
6
6.4.2 CONTACT OUTPUT STATUS
Actual > Inputs/Outputs > Contact Output Status > Board X
(being X the corresponding board in each case).
The corresponding Outputs screen will display the activation of a contact output by lighting up in green the associated LED.
Boards types 1 and 2 have both 8 outputs, so the representation is the same for both types as shown in Table 6–46:
This screen shows the real status of the contact output, which corresponds to the transformation of the output activation
signal (Contact output operate), by the logic applied to this output in “
Setpoint > Inputs/Outputs >Contact I/O > Board X
”
Table 6–46: CONTACT OUTPUT STATUS
NOTE
: Both in the outputs menu as in the rest of menus available in “
Actual
”, the user can view several screens at the
same time to facilitate analysis.
6.4.3 CONTACT OUTPUT OPERATES
Actual > Inputs/Outputs > Contact Output Operates > Board X
(being X the corresponding board in each case).
Table 6–47: CONTACT OUTPUTS OPERATES
These screens are available for all boards incorporated in the relay model, which can be F, G, H, and/or J.
This screen shows the activated or deactivated status of those variables used internally to operate a contact output.
Signals shown on this screen are configured in the Outputs screen inside the
Setpoint > Relay Configuration
menu,
either directly by selecting the signals provided by the relay, or selecting a signal provided by the logic configured at
Setpoint > Logic Configuration.
These logic signals (Contact Output Operates), when being transformed by the outputs logic configured at
Setpoint >
Inputs/Outputs >Contact I/O > Board X
become
Contact Output
signals. This output logic can be POSITIVE,
NEGATIVE, pulse, latched, etc.
CONTACT OUTPUT STATUS
CONT OP_X_01
CONT OP_X_02
CONT OP_X_03
CONT OP_X_04
CONT OP_X_05
CONT OP_X_06
CONT OP_X_07
CONT OP_X_08
BOARD X STATUS
CONTACT OUTPUT
OPERATES
CONT OP OPER_X_01
CONT OP OPER_X_02
CONT OP OPER_X_03
CONT OP OPER_X_04
CONT OP OPER_X_05
CONT OP OPER_X_06
CONT OP OPER_X_07
CONT OP OPER_X_08
BOARD X STATUS
Summary of Contents for Multilin G650
Page 9: ...8 G650 Generator Protection Control System GEK 113285A TABLE OF CONTENTS ...
Page 426: ...GEK 113285A G650 Generator Protection Control System A 31 APPENDIX A A 1 LOGIC OPERANDS A ...
Page 427: ...A 32 G650 Generator Protection Control System GEK 113285A A 1 LOGIC OPERANDS APPENDIXA A ...
Page 587: ...C 22 G650 Generator Protection Control System GEK 113285A C 8 ANALOG INPUTS APPENDIXC C ...
Page 639: ...G 2 G650 Generator Protection Control System GEK 113285A G 1 GE MULTILIN WARRANTY APPENDIXG G ...