GE Motion Sensing Diecast Metal Lantern None Installation Download Page 2

There are 6 preset selections for the amount 
of time the lights stay on: Test (5 seconds), 1, 
5, 10, 15, and 20 minutes. Use a small, phillips 
screw driver to adjust the TIME control (see 
Figure 4). Turn the TIME control until it “snaps” 
into the desired time position.

Replace control panel cover and install the decorative wall plate. In installations where the GE motion sensor 
switch is combined with other switches or outlets on an expanded box, a combination wall plate will need to 
be purchased. Various combination wall plates are available at Home Centers and Electrical Supply Stores.

Slide the switch a couple of times to make sure it operates freely.

When the light in the room is at the 
level you want the lights to turn on, 
set the switch to the AUTO position.
Put  the TIME  control  to  the  5  sec-
ond position.
Put  the  LIGHT  control  to  the  mini-
mum  dark  (fully  counter-clockwise) 
position. Wait  for  the  lights  to  turn 
off.
Turn  the  LIGHT  adjustment  clock-
wise in very small steps and wait 2 
seconds before moving your hand in 
front of the sensor. Repeat until the 
lights controlled by the sensor come 
on. The light will now come on when 
the light level is at or below the pres-
ent level and motion is detected.

To adjust the photocell:

MODE Selection Switch

Moving the switch selects one of three modes of operation: OFF, AUTO, ON

OFF: Lights stay off.

AUTO: Lights come on for time set when motion is detected and the light level is below the set level.

ON: Lights stay on continuously.

 

 

 

The  sensor  can  be  prevented  from  turning  on  lights 
when  there  is  already  enough  light  in  the  room.  Use  a 
small phillips screw driver to set the light level using this  
diagram  as  a  guide.  In  the  fully  clockwise  position, 
the  sensor  turns  on  lights  even  in  full  daylight.  In  the 
fully  counter-clockwise  position,  the  sensor  only  turns 
on  lights  when  the  surrounding  light  level  is  very  low.

ADJUSTMENTS

USE

TIME

Complete Installation

LIGHT LEVEL

- 3 -

Electrical  input................................................................................................................................120V,  60  Hz

Fluorescent Load.............................................(2 tube minimum) 30 Watt minimum 400 Watt maximum Rapid Start

Motor  Load.............................................................................................................................1/8  HP  maximum

Incandescent.........................................................................................................................500W  maximum

On-Time..........................................................................................Adjustable  approximately  5  sec.  to  20  min.

Photocell  Sensor.......................................................................................From  full  daylight  to  less  than  1  FC.

Coverage...............................................................................up to 15 ft. at 150°, up to 30 ft. in front of the sensor

SPECIFICATIONS

TROUBLESHOOTING

- 4 -

SYMPTOM

Light does not 
come on.

Lights do not stay
on in the Auto mode.

POSSIBLE CAUSE

Circuit  breaker  or  fuse  is 
turned off.
If  the  lamp  being  con-
trolled has another switch, 
it may be turned off.
Bulb is defective.
LIGHT control is set too far 
toward  the  DARK  position. 
MODE  switch  is  set  to 
OFF instead of AUTO.
Poor connection.

Motion has stopped in the 
room.
TIME control is set for too 
short a delay.

1.

2.

3.
4.

5.

6.

1.

2.

SYMPTOM

Light does not 
turn off.

Light comes on for 
no reason in the Auto 
mode.

POSSIBLE CAUSE

Incorrect wiring.
MODE switch is set to 
ON instead of AUTO.
Motion is still present.
Delay  set  by  TIME 
c o n t r o l   h a s   n o t 
expired.

Heating or cooling ob- 
jects  (such  as  air 
vents,  appliances,  or 
drafts through the wall 
box) are causing false 
triggering.
Switch  on  the  sensor 
has  been  turned  off 
and back on.
There  was  a  momen-
tary  power  interrup-
tion. The light will turn 
off automatically when 
the "on" time expires.

1.
2.

3.
4.

1.

2.

3.

 WARNING

Risk of electric shock
  Shut off power at fuse box or

  circuit breaker before installation
  Use indoors only
Risk of fire
  Do not exceed electrical ratings

T I M E

L I G H T

+

Test

20

15

1

5

10

Dark (low

light level)

Any Light Level

5 Seconds

20 Minutes

Reviews: