GE MONOGRAM ZV800SJSS Technical Service Manual Download Page 15

– 15 –

Transformer

Capacitor

PTC Board

Triac

Power Supply Board

Transformer

The transformer supplies 12 VAC to the  power 
control board (PCB) and the lighting circuit. It is held 
in place by two Phillips-head machine screws and   
7 mm hex nuts.

Transformer Resistance:

Primary winding (black to white wires) - 7 

Ω. 

Secondary winding (blue to brown wires) - 0.3 

Ω.

Check for 120 VAC between the white and black 
wires. Check for 12 VAC between the blue and 
brown wires. 

Triac 

The triac controls the two hood lights. It is located 
inside the upper component box. It is held in place 
by 2 Phillips-head machine screws and 7 mm hex-
nuts.

If the hood lamps fl icker, the triac wire connections 
are incorrect. The triac can be checked for an 
electrical short by removing the black lead wire and 
measuring the resistance between the two ¼-in. 
terminals (black and brown wires). Resistance should 
be greater than 1M 

.

PTC Board

The PTC board provides protection for the lighting 
circuit during momentary power surges. It is located 
inside the upper component box.

Motor Capacitor

The motor capacitor has a value of 25 

µ

fd. It is 

located inside the upper component box.

Upper

Lower

Power Supply Housing

WARNING:

 Components in the power supply 

housing are electrically 

HOT

 when voltage is 

connected to the hood.

The power supply housing is located above the fan 
housing behind the duct cover. To access the power 
supply housing, remove the duct cover, (see 

Duct 

Cover

) then remove the 2 Phillips-head screws that 

hold the power supply cover in place. 

Power Supply Housing Cover

Screw

Screw

The transformer is located in the power supply 
housing. The triac, fuse holder, motor capacitor, and 
power supply board are located in the power supply 
housing in separate upper and lower component 
boxes. 

Summary of Contents for MONOGRAM ZV800SJSS

Page 1: ...MODEL SERIES ZV800SJSS ZV800BJBB TECHNICAL SERVICE GUIDE GE Consumer Industrial Monogram 36 in Chimney Vent Hood PUB 31 9132 03 05...

Page 2: ...avoid personal injury disconnect power before servicing this product If electrical power is required for diagnosis or test purposes disconnect the power immediately after performing the necessary chec...

Page 3: ...Motor Assembly 17 Filters 10 Glass Visor 8 Installation Information 7 Introduction 4 Lights 12 Light Receptacles 13 Nomenclature 5 Power Supply Housing 15 Push Button Assembly 12 Push Button Controls...

Page 4: ...py is sleekly styled with a streamlined design seamless nished edges and front mounted touch controls Powerful ventilation A four speed 500 CFM fan blower with boost option captures the smoke and stea...

Page 5: ...tter designating the year repeats every 12 years Example T 1974 T 1986 T 1998 Z V 800 S J SS Monogram J Model Year S Stainless Steel B Black Features Vent SS Stainless Steel BB Black on Black Nomencla...

Page 6: ...washers used to complete a path to ground are removed for service they must be returned to their original position and properly fastened GROUNDING SPECIFICATIONS Ground Path Resistance 0 10 Max Insul...

Page 7: ...t installation Custom cabinet modi cation is required for recirculating operation Installation Information The vent hood is heavy Adequate structural support should be provided in all types of install...

Page 8: ...Grasp the visor and pull it out to remove steam more ef ciently when cooking Push it back when not in use The vent fan and lights work with the visor in or out Cleaning To preserve and protect the ne...

Page 9: ...pply Housing Cover Canopy Visor Light Fan assembly Light 3 2 4 1 5 Power Supply Housing Components 1 Transformer 2 Triac 3 PTC Board 4 Capacitor 5 Power Control Board PCB Front View Shown with decorat...

Page 10: ...d to the outside the air will be recirculated through an additional single disposable charcoal lter that helps remove smoke and odors To remove the charcoal lter rst remove the 2 grease lters Grasp th...

Page 11: ...track inward to clear the canopy then remove it 6 Remove the 2 Phillips head screws that attach the ribbon receptacle to the left track 7 Remove the single Phillips head screw that holds the black rib...

Page 12: ...ace by a bracket with 3 thumb screws Access to the push button assembly is located behind a cover on the underside of the visor To remove the push button assembly 1 Remove the 2 Phillips head screws t...

Page 13: ...t Receptacles The 2 light receptacles are recessed in the light shield and are located on the underside of the canopy Each receptacle consists of a bulb socket and glass cover WARNING Before replacing...

Page 14: ...et the upper duct section fall into the lower duct section Damage to the canopy can occur 2 Remove the two Phillips head screws one on each side that attach the upper section of the duct cover to the...

Page 15: ...g the resistance between the two in terminals black and brown wires Resistance should be greater than 1M PTC Board The PTC board provides protection for the lighting circuit during momentary power sur...

Page 16: ...s follows Insert screwdriver in the center of the space between the plug and connector receptacle on the PCB Push down on the screwdriver handle pivot blade about 5 degrees and pull out the plug at th...

Page 17: ...Remove the duct cover See Duct Cover 5 Remove the power supply housing cover See Power Supply Housing 6 Remove the 4 Phillips head screws that hold the lower electrical component cover in place Remov...

Page 18: ...to the fan power cable Insert the fan wiring through the power supply housing wire entry inlet 12 Grasp the fan motor assembly from the bottom Remove the 4 Phillips head screws that hold the fan motor...

Page 19: ...MOTOR NO CHECK IF 120V AC IS PRESENT AT MOTOR TERMINAL BLOCK IN LEFT BLACK BOX NO YES ORDER MOTOR INSPECT PCB IN BLACKBOX NOTE 1 HOOD OK NO DONE ORDER INSTALL ENTRY DISPLAY ASSEMBLY CONTROL PCBS NO LI...

Page 20: ...uctors Speed Test Wires Wires Jumped Resistance ohms 5 at 68 F 20 C 1 red black blue orange 20 6 2 red black white orange 14 4 3 red white white orange 7 6 BOOST red black black orange 7 6 MOTOR TEST...

Page 21: ...ing Diagrams 42 0 42 3 2 2 2 7 2 7 2 7 2 7 2 7 2 7 6 6 6 2 2 54 7 4 7 4 5 5 2 3 4 42 5 5 5 7 4 7 4 2 5 2 2 7 7 4 4 2 4 2 2 93 2 02 33 2 2 5 4 7 6 4 0 7 2 3500 9 4 2 0 4 23 0 0 0 0 2 5 2 2 7 3 4 6 M 6...

Page 22: ...tes do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may...

Reviews: