GE MONOGRAM ZV750SY Installation Instructions Manual Download Page 3

3

Design Information

36" Vent Hood

Model
ZV750SY

Model
Available

Optional
Accessories

This vent hood is designed to be used in
vented installations.

A decorative duct cover is provided to cover
the duct from the top of the hood to an 8 ft.
or 9 ft. ceiling.

The vent hood must be installed 24" min. and 30" max.
above the cooking surface. 25-1/2" is recommended to
insure that the duct cover meets the ceiling. The cooking
surface should be at least 36" above the floor. Installation
will be easier if the vent hood is installed before the
range or cooktop and countertop is installed.

Product
Dimensions
& Clearances

*Height 

to Ceiling

8-1/4"

34-5/8"

21-5/8"

Model
ZX10SY

An optional stainless steel duct cover is
available for 9 ft. to 10 ft. ceiling installations.
(The supplied duct cover is sized to reach 8 ft.
to 9 ft. ceilings.) Order the optional duct
cover at the same time as the vent hood and
have on site before installation.

*26-1/4" for 8 ft. ceiling

38-1/4" for 9 ft. ceiling

38-1/4" to 50-1/4" for 9 ft. to

10 ft. ceiling using optional

accessory ZX10SY Duct Cover

*The distance between the cooking surface and the bottom of the

hood must be at least 24" and up to 30". The 25-1/2"

recommended installation height, above the standard 36"

countertop, will insure duct cover fit to the ceiling.

*25-1/2" Recommended

36" Min.

Summary of Contents for MONOGRAM ZV750SY

Page 1: ...GE Monogram Installation Instructions 36 Vent Hood Model ZV750SY...

Page 2: ...HE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have any ques tions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel a...

Page 3: ...nd countertop is installed Product Dimensions Clearances Height to Ceiling 8 1 4 34 5 8 21 5 8 Model ZX10SY An optional stainless steel duct cover is available for 9 ft to 10 ft ceiling installations...

Page 4: ...g local codes and ordinances Electrical supply This vent hood must be supplied with 120V 60Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit bre...

Page 5: ...m duct length 100 foot for range hoods Flexible ducting If flexible metal ducting is used all the equivalent feet values in the table should be doubled The flexible metal duct should be straight and s...

Page 6: ...ides on the left and right sides Discard the shipping board Remove junction box cover Remove knockout from junction box Install strain relief onto junction box Safety glasses Tape to mount template Gl...

Page 7: ...should be 61 1 2 above the floor Measure 36 from the floor to top of cooking surface add 25 1 2 to bottom line indicated on template Tape the template in the installation location BE SURE THE TEMPLAT...

Page 8: ...f mounting the hood to studs and to hollow wall Drill 1 8 pilot holes in all locations Enlarge holes that did not enter studs to 3 8 and tap anchors for molly bolts into the holes 5 Step Install the H...

Page 9: ...etween the hood outlet and the ductwork at the ceiling Position the upper duct bracket behind the duct and against the wall and ceiling Mark the 4 screw locations Remove the bracket and temporary duct...

Page 10: ...ead Connect green yellow leads to branch circuit green or bare ground lead Secure all connections with wire nuts on each electrical connector Push wires into junction box and replace cover Be sure wir...

Page 11: ...ull the knob forward until the filter rests on the slots To remove the filters grasp the knob and push the filter towards the rear and tilt downwards 11 10 Step Install Filters Finalize Installation S...

Page 12: ...glasses or goggles should be worn To obtain specific information concerning any Monogram product or service call GE Answer Center consumer information service at 800 626 2000 any time day or night For...

Reviews: