– 9 –
Halogen Lamp Assembly Replacement
1. Remove the ring nut by turning it counter-
clockwise.
2. Grasp the bulb on the edges and pull it
straight out.
3. Remove 3 filters from the fan housing.
4. Remove 2 screws and lamp protection
from the hood.
5. Disconnect wires from lamp socket.
CAUTION: Replace the lamp with the same
size bulb. These 12-volt, 20-watt halogen bulbs
are available at specialty lighting stores. Ask for
GE bulb or equivalent: Q20 MR16/FL 40°–BAB.
Note: When reinstalling, ensure that all electrical
connections are securely fastened.
Filter Replacement
(Access to lighting and wiring)
1. Grasp knob and push filter back into rear
recess to release front edge of filter from track.
2. Pull front edge of filter down.
3. Pull filter toward you to remove.
GEA00007
Component Access/Duct Cover Removal
Model ZV750, Wall-Mounted Hood
Note: A ladder or step stool is needed for the
following procedure.
1. Remove 2 screws from the top duct cover at
the ceiling and slide the top cover down (see
illustration).
2. Lift and remove both duct covers. Set covers
aside.
GEA00005
Service
Manual
Envelope
Triac
Junction
Box
Transformer
Black Box
(Control PCB)
ZV750
GEA00006