GE Monogram ZTS90DSSNSS Installation Instructions Manual Download Page 6

6

  MAKE ELECTRICAL CONNECTIONS

WARNING

 Switch power off at the service panel and lock the service disconnecting means 

to prevent power from being switched on accidentally. When the service disconnecting means cannot 
be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Place oven on table or platform even with the cutout opening. For a single oven, the platform must 
support 220 lbs. (99 kg); for a double or combination oven, the platform must support 400 lbs.  
(181 kg). Connect the flexible conduit to the electrical junction box as shown below*. Position the 
conduit in such a manner that it will lie behind the unit in a natural loop when the oven is installed**. You 
will need to purchase an appropriate strain relief clamp to complete the connection of the conduit to the 
junction box.

* Ovens come equipped with a 40” or 54” long conduit. If a longer conduit is desired, there may be one 

available for your model. To check availability or order parts, call GE Appliances at 1.800.GE.CARES.

** Combination Oven with upper microwave oven - it is recommended to install the conduit 

through the side of the junction box as shown in the illustration above.

7

  THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION

NOTE: 

If residence leads are aluminum conductors, see 

WARNING 

in Section 5, Electrical Requirements.

When connecting to a three-conductor branch circuit, if local 

codes permit:

A.

  Connect the oven ground conductor along with the 

neutral (white) lead to the branch circuit neutral (white 
or gray in color), using a wire nut.

B. 

 Connect the oven red lead to the branch circuit red 
lead and the oven black lead to the branch circuit black 
lead in accordance with local codes, using wire nuts.

C.

 Install proper strain relief clamp.

D.

 Install junction box cover.

Ground and 

neutral wires (white)

Tape or Crimp

Neutral wire 

connection

Black

Red

Branch 

circuit

Alternate 

knockout

Range 

conduit 

snaps 

into box

Junction Box Cover

5

  ELECTRICAL REQUIREMENTS (CONT.)

This appliance must be supplied with the proper voltage and frequency and connected to an individual, 
properly grounded branch circuit, protected by a circuit breaker or fuse. See the rating plate located on 
the oven frame to determine the rating of the product. 

Use the chart below to determine the minimum recommended dedicated circuit protection:

DO NOT shorten the flexible conduit. The conduit strain relief clamp must be securely attached to the 
junction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will 
not fit within the clamp, do not install the oven until a clamp of the proper size is obtained.

The 3 power leads supplied with this appliance are suitable for connection to heavier gauge household 
wiring. The insulation of these 3 leads is rated for temperatures much higher than the temperature 
rating of the household wiring. The current-carrying capacity of the conductor is governed by the wire 
gauge and the temperature rating of the insulation around the wire.

Rating plate is located on the oven side trim.

KW Rating 

240V

KW Rating 

208V

Recommended 

Circuit Size 

(Dedicated)

”.:

”.:

20 Amp

4.9 KW–7.2 KW

4.2 KW–6.2 KW

30 Amp

7.3 KW–9.6 KW

6.3 KW–8.3 KW

40 Amp

9.7 KW–12.0 KW

8.4 KW–10.4 KW

50 Amp

Junction Box 

Conduit

Ground

Red

White

Black

Strain Relief Clamp 

(not included) Must 

Be Used at Junction 

Box

Place Oven on a 

Support to Assist in 

Connecting Conduit

Ground 

Wire

Summary of Contents for Monogram ZTS90DSSNSS

Page 1: ...remove plastic on trims and panel all tape around the oven and any shipping screws securing the oven to the base pad Open oven door and remove literature pack and oven racks Remove the bottom trim fr...

Page 2: ...0 Single Oven A Cabinet Width 25 63 5 cm min 251 4 64 1 cm max 281 2 72 4 cm min 285 8 72 7 cm max B Cutout Height 275 8 70 2 cm min 281 8 71 4 cm max 271 4 69 2 cm min 275 16 69 4 cm max C Clearance...

Page 3: ...11 4 3 2 cm 11 4 3 2 cm H Junction Box Location 83 4 22 2 cm max right side only 91 2 24 1 cm max right side only 91 2 24 1 cm max right side only J Height to Bottom of Junction Box 44 111 8 cm 47 11...

Page 4: ...ment 2 5 1 cm Min Per Warming Drawer Requirement Continue to Section 3 for Double Wall Oven with Pedestal Otherwise continue to Section 4 3 A DETERMINING WHEN TO USE THE PEDESTAL 30 DOUBLE OVENS ONLY...

Page 5: ...WARNING To prevent shock remove house fuse or open circuit breaker before beginning installation WARNING Improper connection of aluminum house wiring to copper leads can result in an electrical hazard...

Page 6: ...and the oven black lead to the branch circuit black lead in accordance with local codes using wire nuts C Install proper strain relief clamp D Install junction box cover Ground and neutral wires white...

Page 7: ...oven B Lift oven into cabinet cutout using the oven opening as a grip Carefully push against oven front frame Do not push against outside edges C As you slide the oven back pull the string so that the...

Page 8: ...see Section 11 Ensure that air duct opening at bottom of unit is free of obstructions Check that oven rack guides if applicable are installed correctly and oven racks function smoothly If applicable...

Page 9: ...ebordes y panel toda la cinta que cubre el horno y los tornillos de env o que fijan el horno a la almohadilla base Abra la puerta del horno y quite el material informativo y las bandejas del horno Qui...

Page 10: ...binete 25 63 5 cm m n 251 4 64 1 cm m x 281 2 72 4 cm m n 285 8 72 7 cm m x B Altura de la abertura 275 8 70 2 cm m n 281 8 71 4 cm m x 271 4 69 2 cm m n 275 16 69 4 cm m x C Espacio desde la abertura...

Page 11: ...tura parte superior 1 2 5 cm min 1 2 5 cm min 11 4 3 2 cm para PT9550 ZET2S y ZET2P 1 2 5 cm min 11 4 3 2 cm para PT9550 ZET2S y ZET2P G Espacio desde la abertura parte inferior 1 2 5 cm min 11 4 3 2...

Page 12: ...l gabinete se encuentra en la condici n de ancho m ximo repare los tacos de madera como se muestra en la ilustraci n 3 B INSTALACI N DEL RIEL CON PEDESTAL 30 HORNOS DOBLES NICAMENTE A Posicione los ri...

Page 13: ...este aparato ADVERTENCIA Para prevenir una descarga el ctrica quite el fusible o abra el interruptor de circuitos antes de comenzar la instalaci n ADVERTENCIA Una conexi n inadecuada de cableado dom s...

Page 14: ...kg Conecte el conducto flexible a la caja de conexiones el ctrica como se indica abajo Posicione el conducto de modo tal que se apoye detr s de la unidad en un c rculo natural cuando el horno sea inst...

Page 15: ...locales A Evite que el conductor neutro blanco quede enredado con cualquier otro cable De ser necesario corte el conductor neutro blanco y luego vuelva a pelar el mismo a fin de exponer la longitud ad...

Page 16: ...bstrucciones Controle que las gu as de los estantes del horno si corresponde est n instaladas de forma correcta y que los estantes del horno funcionen de forma fluida Si corresponde instale las manija...