background image

Specification Revised 10/05 

130716

Monogram.

ZTD910BF/SF/WF – GE Monogram 30" Warming Drawer 

For answers to your Monogram,

®

 GE Profile

 or  

GE appliance questions, visit our website at

GEAppliances.com or call 

GE Answer Center

®

 service, 800.626.2000.

 

Electrical

Outlet 16" Max.

From Left Side

Installation Belo

w

a Dr

aw

er

23-1/2 Min.

Solid Barrier

1/4

Air Gap

25

1-1/2 Cabinet Top

36

Countertop

Height

1 Min.*

28-1/2

9-1/4

Electrical Outlet 42" Max.

From Right Side 

Install a Solid Barrier

Below a Cooktop

See Note

Electrical Outlet

Flush With Side

of Cabinet 7" Max.

9

Install

2x4 or 2x2

Anti-Tip Block

Against Rear

Cabinet Wall

9" From Floor

to Bottom

of Block

7

Install a Solid Barrier

and a 1/4" Air Gap

Above Warming Drawer

Undercounter Installation (in inches)

Note:

 When installing warming drawer with a cooktop, 

allow a 2" minimum from cooktop burner box bottom to  

top of cut-out.

Important Installation Note:

  

Must provide anti-tip brace at the back of the cabinet and 

at the top of the cutout.

Optional Accessories:
ZXD30B 

– 3/4" wood panel trim kit

• When installed, the front face of the drawer will be nearly flush 

with adjacent cabinetry doors.

• Drawer overlaps will conceal cut edges on all sides of the opening.

  The rough opening for the drawer must be: 

–Depth 23-1/2" min. from inside back to front of cabinet frame. 

–Width 25-1/2" for 27" wide models, 28-1/2" for 30" wide models. 

–Height 9-1/4"

• 5" min. above floor or 1" above toekick. 23-1/4" from floor to bottom 

of cutout is recommended for under countertop installation.

Installation below a cooktop:

Warming drawers are approved for installation below only certain 

specified cooktop models. See the label attached to the top of the 

warming drawer for approved models. A solid barrier and air gap 

between cooktop and warming drawer is required. See Note above.

Installation below a cabinet drawer:

The warming drawer may be installed beneath a cabinet drawer. In 

this installation, a solid barrier should be installed above the warming 

drawer to block access. Use any solid material such as 1/4" thick  

plywood. Allow at least 1/4" air gap between the barrier and the 

top of the warming drawer. Observe the 5" min. above the floor or 1" 

above the toekick minimum installation height.

Note: 

If you are installing in frameless cabinets, it may be necessary 

to install 1/2" wide cleats to accept drawer mounting screws. See 

drawer to find exact locations of mounting screws.

Side to Side Installation:

Install two warming drawers in separate cutouts. Allow 2" min. 

between cutouts.

* Note:

 When installing the warming drawer below a 

cooktop, a solid barrier must be installed at 1" from the 

lowest point of the bottom of cooktop burner box to the 

top of cutout. Use any solid material such as 1/4" thick 

plywood. Allow at least 1/4" air gap between the barrier 

and the top of the warming drawer. See label on top of 

the warming drawer for approved cooktop models.

2

Min.

Side to Side Installation

R

Listed by 

Underwriters 

Laboratories

Reviews: