background image

-3-

STEP 4  Install Bin Drain Tube

A. 

Attach drain tube from bin to pump with

original hose clamp from old drain tube.

B. 

Secure the pump to the base with the 2
supplied screws.

STEP 5  Secure Vent Tube

• Place rear cover against the back of the icemaker.

Route the vent tube and drain tube through cutouts
in the rear cover.

• Secure rear cover with original screws.
• Secure vent tube to the back of the icemaker with the

3 clamps and 3 remaining screws.

• Route drain tube to house drain.

Vent Tube

Mounting Clamp

and Screw

Vent Tube

Original Icemaker

Power Cord

Pump Mounting Screws

Connect

Bin Drain

Tube

A

B

Summary of Contents for Monogram ZPK1

Page 1: ...s vent and drain tube to pump Hose Clamp 5 8 secures drain tube to bin If Icemaker Is Presently Installed Push the selector switch to OFF Unplug icemaker or disconnect power Shut off water supply Wait 5 to 10 minutes for the ice to fall into the storage bin Remove all ice from the bin Disconnect the water inlet line from the water valve If the icemaker is installed between cabinets pull icemaker o...

Page 2: ...ginal clamp and screw C Plug the icemaker power cord into the side of the pump STEP 3 Install New Tubing A Attach new drain tube to pump check valve outlet with new 1 2 hose clamp B Attach vent tube to pump with new 1 2 hose clamp C Coil icemaker power cord into a 4 dia coil and secure with electrical tape Place the coil over the top of the pump D Carefully slide the drain pump into the bottom rig...

Page 3: ...Place rear cover against the back of the icemaker Route the vent tube and drain tube through cutouts in the rear cover Secure rear cover with original screws Secure vent tube to the back of the icemaker with the 3 clamps and 3 remaining screws Route drain tube to house drain Vent Tube Mounting Clamp and Screw Vent Tube Original Icemaker Power Cord Pump Mounting Screws Connect Bin Drain Tube A B ...

Page 4: ...lve inlet cover and attach copper tubing with a compression nut and sleeve Check to be sure copper tubing does not touch the side wall or other parts inside the cabinet Turn on the water and check all connections for leaks Water Line Access Holes Water Inlet Water Outlet Check to be sure copper tubing does not touch the side wall or other parts inside the cabinet Turn on the water and check all co...