background image

Installation

Instructions

31-49062-1 
224D2601P002 

10-14  GE

36” Built-In All-Refrigerators  
and All-Freezers

monogram.com

Summary of Contents for Monogram ZIF360NHLH

Page 1: ...Installation Instructions 31 49062 1 224D2601P002 10 14 GE 36 Built In All Refrigerators and All Freezers monogram com ...

Page 2: ... could result in minor or moderate injury WARNING DANGER CAUTION For Monogram local service in your area call 1 800 444 1845 For Monogram service in Canada call 1 800 561 3344 For Monogram Parts and Accessories call 1 800 626 2002 www monogram com WARNING Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove the ground prong Do not use an adapter Immediately replace electric co...

Page 3: ...ème anti basculement AVERTISSEMENT Risque d explosion Conservez les matériaux et vapeurs inflammables tels que l essence à l écart de votre réfrigérateur Le non respect de cette instruction peut entraîner un risque d incendie d explosion ou de décès AVERTISSEMENT Pour réduire le risque d étouffement pendant l installation de ce produit ne pas laisser les petites pièces à la portée des enfants âgés...

Page 4: ... Step 1 Remove Packaging 16 Step 2 Install Water Line 16 Step 3 Install Side Panels 16 Step 4 Install Case Trim 17 Step 5 Anti Tip Procedures 18 19 Step 6 Level Unit 20 Step 7 Secure Unit to Cabinetry 20 Step 8 Secure Unit to Wall 21 Step 9 Adjust Door Swing 23 Step 10 Remove Door Trim 22 Step 11 Layout Decorative Door Panels 23 Step 12 Attach Brackets to Panels 24 Step 13 Hang Decorative Door Pan...

Page 5: ...r back wall The water line should be 1 4 O D copper tubing or GE QuickConnect kit between the cold water line and water connection location long enough to extend to the front of the unit Installation of an easily accessible shut off valve in the water line is required DIMENSIONS AND CLEARANCES Shipping height The product can be adjusted to fit into a cutout that is 84 1 2 max height Note that the ...

Page 6: ... Cold Water Supply 24 Minimum Cutout Depth 84 1 2 Max Finished Opening 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 Clearances for Multiple Single Door Installations In a side by side installation of a left and right door swing product a 1 1 2 clearance between the units is required Order ZUGF2 Unified Grille Panel Kit for one continuous grille panel 15 Min to Wall 15 Min to Wall 11...

Page 7: ...upply is recommended for each product Clearances for Multiple Single Door Installations In a side by side installation of a left and right door swing product a 1 clearance between the units is required Order ZUGSS2 Stainless Steel Unified Grille Panel Kit or ZUG2 Custom Panel Unified Grille Panel Kit for one continuous grille panel Clearances for two products installed side by side with the same l...

Page 8: ...ainless Steel handles designed to fit 3 4 overlay panels ZKHPSS1 Pro Tubular Stainless Steel handle designed to fit 3 4 overlay panels ZUG2 For side by side installation of two trimmed models This kit provides for the installation of a unified custom grille panel to span the width of two units using a framed or overlay panel ZUGSS2 For side by side installation of two stainless steel wrapped model...

Page 9: ...el 18 lbs 1 2 1 2 1 1 4 1 1 1 4 1 Top Bottom Hinge Clearance Router 1 8 Deep Grille Panel Door Panel 38 9 5 8 69 13 16 CUSTOM HANDLE DESIGN GUIDE Flush Installation Only For custom handle installation counterbore holes in rear of decorative panels may not exceed 1 4 depth to ensure 1 2 material thickness remains for handle support NOTE The counterbore must not exceed 1 in diameter Minimum distance...

Page 10: ...t be placed between the overlay and backer panel IMPORTANT NOTE Maximum total weight for assembled door panel is 67 pounds Maximum total weight for assembled grille panel is 11 pounds Assemble the panels with glue and screws Center the spacer panel on the backer panel left to right and top to bottom Secure the panels with glue Center the spacer and backer panel on the overlay panel and secure with...

Page 11: ...nel Dimensions A Width B Height 1 4 Framed Panel 69 7 8 8 7 8 Overlay Panel Dimensions A Width B Height 1 4 Backer Panel 69 7 8 8 7 8 0 10 Spacer Panel 68 1 2 7 5 8 3 4 Overlay Panel 70 1 8 9 IMPORTANT NOTE The maximum weight for the unified grill is 25 pounds Design Guide 84 2 9 16 24 3 to 4 3 16 1 7 8 SIDE CLEATS Flush Installation Only Wood cleats are required to be installed vertically down bo...

Page 12: ...ard Installation Only Scale 1 1 Frameless Cabinets The case trim overlaps cabinets at the top and sides Therefore frameless cabinets may require filler strips to prevent interference with cabinet door swing The opening must allow for filler strips ...

Page 13: ...inal Size Case Trim Refrigerator or Freezer Door Top View 90 DOOR SWING Standard Installation Only Scale 1 1 Frameless Cabinets The case trim overlaps cabinets at the top and sides Therefore frameless cabinets may require filler strips to prevent interference with cabinet door swing The opening must allow for filler strips ...

Page 14: ... which mates with a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded Where a standard 2 prong wall outlet is encountered it is your personal responsibility and obligation to have it replaced with a properly grounded 3 pr...

Page 15: ... Bracket Top Right Panel Bracket Bottom Left Panel Bracket Bottom Right Panel Bracket Top Left Panel Bracket Top Panel Bracket Bottom Door Bracket 4 Installed on door TOP IF HINGES ARE ON THE LEFT TOP IF HINGES ARE ON THE RIGHT BOTTOM IF HINGES ARE ON THE RIGHT BOTTOM IF HINGES ARE ON THE LEFT Door Panel Template Grille Template Door Trim Top Door Trim Bottom ...

Page 16: ...ter supply line because the line is under pressure at all times Other types of plastic may crack or rupture with age and cause water damage to your home GE SmartConnect Refrigerator Tubing Kits are available in the following lengths 2 6 m WX08X10002 8 2 4 m WX08X10006 15 4 6 m WX08X10015 25 7 6 m WX08X10025 The unit is secured to the skid with 4 slotted tie down straps Remove the four 5 16 bolts f...

Page 17: ...e center of the studs Mark the wall at these points Installation Instructions 17 WARNING Tip Over Hazard The unit is top heavy and must be secured to prevent the possibility of tipping forward AVERTISSEMENT Risque de basculement L appareil ménager est beaucoup plus lourd en haut et il faut le maintenir en place pour éviter la possibilité de son basculement vers l avant Flush Installation Only Cut ...

Page 18: ... end of the bracket mark an additional hole towards the center of the bracket Drill 1 2 holes into the wall board at the locations marked for the toggles to be mounted not the stud markings Drill 3 16 holes into wooden studs where marked If steel stud construction drill 1 2 holes into the studs where marked You will use 2 toggles with the metal studs Install Wall Toggles The wall toggles and bolts...

Page 19: ...orward down and out to remove Power Cord Locate the power cord inside the left cavity If it has not been adjusted so the plug is easily accessible do so now Move Unit into Final Position Move appliance toward its final installed location Align the tabs on the wall bracket with the openings in the back of the unit The unit has L bolts in the upper left and right corners inside of the access compart...

Page 20: ...nners Cabinetry trim could also be added across the top of the opening to shorten the opening If you attempt to raise the unit more than 1 you will damage the front leveling legs and the rear leveling wheels ATTENTION Les roues de nivellement arrière et les pattes de nivellement avant permettent un réglage maximal de 25 mm 1 po Si l ouverture pour l appareil ménager a une hauteur supérieure à 2 15...

Page 21: ...cal position Do this to both sides Pull out on the end of the rod to make sure it is secure in the bracket Locate the hole on the rod that is closest to the unit A hair pin cotter will be put through this hole to secure the rod If this hole appears to be too far away for a snug fit against the unit add the washers one at a time until the pin will fit tightly into the hole Align the straight sectio...

Page 22: ...tallation Instructions 22 Pin Location for 90 Door Swing Pin Location for 130 Door Swing Pin Location as Shipped for 115 Door Swing STEP 10 REMOVE DOOR TRIM FLUSH INSTALLATION ONLY Use the supplied Torx wrench or T10 Torx head driver to remove all exposed trim screws securing aluminum trim to door Save all trim and screws as they will be replaced in a later step 1 Remove 6 screws and trim from the...

Page 23: ...of door panel 7 Remove the tape from the panel Slide the templates to the bottom of the panel aligning the bottom sides and centerline of the panel with the bottom sides and cen terline of the template Tape in place 8 Using a 1 8 wood drill bit drill pilot holes into the door panels 1 4 deep through only the bottom group of holes in the templates Four holes will be drilled into the bottom corners ...

Page 24: ...l bracket with the four pilot holes at the bottom hinge side of the door panel making sure the angled portion of the bracket is facing the perimeter of the door Fasten the bracket using four screws 3 Align the four tapered holes in one of the top panel brackets with the four holes in the top of the door panel on the handle side Fasten the bracket using four screws 4 Align the four tapered holes in...

Page 25: ...the top of the panel brackets and gently allow the bottom edge of the panel to lay against the door as it hangs freely 2 Adjust the panel by pushing it flush against the door 3 Using supplied washer head screws secure panel brackets mounted to the rear of the wooden panels to the door top side and bottom Each screw should be tightened until snug and then backed off 2 3 turns to allow for fine tuni...

Page 26: ...the grille panel with the lettering face up Align the top side and cen terline of the template with the top side and centerline of the door Tape the template in place using masking tape 5 Using a 1 8 wood drill bit drill pilot holes into the grille panel deep 6 Remove tape and discard template STEP 15 INSTALL GRILLE PANEL FLUSH INSTALLATION ONLY 1 Pull grille panel bracket in an outward motion all...

Page 27: ...ening Check the gap by closing the door 3 Check that the door panel is in plane with the face of the cabinets The panel can be adjusted outward by turning the set screw threaded into the tab of the door bracket at the top and bottom of the door clockwise until the face of the panel is in the same plane as the cabinetry 4 Check the flushness of the panel with the cabinetry If the grille is not flus...

Page 28: ... side washer head screws NOTE Over tightening washer head screws may result in bending wood panel brackets as well as misaligning wood door panels 7 Drive the door anchor screws through the two white plastic pock ets in the side of each door and into the door panel 4 each door to prevent panel warping over time 28 Installation Instructions STEP 17 REPLACE TRIM FLUSH INSTALLATION ONLY 1 Replace tri...

Page 29: ...he tubing into the appliance or freezer connection Tighten the compression nut until it is just hand tight Tighten one additional turn with a wrench Overtightening can cause leaks Turn on the water to check for leaks NOTE Make sure excess tubing length does not interfere with the toekick installation Freezer Water Supply House Water Supply STEP 19 START ICEMAKER FREEZER MODELS ONLY Slide the switc...

Page 30: ...Notes 30 ...

Page 31: ...Notes 31 ...

Page 32: ...be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice 31 49062 1 224D2601P002 10 14 GE GE Appliances Appliance Park Louisville KY 40225 GEAppliances com ...

Reviews: