background image

Design Guide

4

THE INSTALLATION SPACE

IMPORTANT: Double-Drawer Refrigerators are
designed to be built-in only. They cannot be used 
free-standing. 

The cutout depth should be 24

NOTE: 

The unit is designed to be flush with the

surrounding cabinets.

Additional Specifications

• A 120 volt 60Hz., 15 or 20 amp power supply is required.

An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded 
3-prong electrical receptacle recessed into the back 
wall as shown. Electrical must be located on rear wall 
as shown. 

NOTE: 

GFCI (ground fault circuit interrupter) 

is not recommended.

PRODUCT CLEARANCES

When installed 
in a corner:

Allow 2-1⁄2

min. clearance between Double-Drawer

and adjacent cabinet, wall or other appliances. 
Allow 22

min. clearance from the front for drawer

opening.

NOTE: 

Clearances are based on the noted 2-1⁄8

handle standoff depth.

• Test the drawer openings. Carefully open and close

the drawers. The drawers should not rub or catch on
adjacent cabinetry. Notify the installer if the drawers
make contact with cabinetry. 

Choose the location:

• These products may be closed in on the top and 

three sides as long as the front is unobstructed for 
air circulation and proper access to the drawers.

• Do not install these products where the temperature

will go below 55°F (13°C) or above 90°F (32°C).

• These products are not designed to be stacked one over

the other.

SIDE-BY-SIDE INSTALLATIONS – 

Stainless Steel Models Only

For a complete refreshment center, install a Double-Drawer
Refrigerator beside a Beverage Center, Wine Chiller/
Wine Reserve, Fresh-Food Refrigerator or Bar Refrigerator 
with Icemaker.
• A side-by-side installation requires at least a 47-1/2

wide

opening. No trim kits required.

• Products must operate from separate, properly grounded

receptacles.

34-1/2"-35"

24"

47-1/2" Min.

1-1/2" 

9"

 

10-1/2"

 

9"

 

10-1/2" 

14"

 

15" 

Locate

Outlet

23-3/4" 

34-1/4"

25-7/8"  
Including  
Handles

Locate  
Outlet 

34-1/2"-35"

24"

23-3/4" Min.

1-1/2" 

9"  

Max.

8-1/2" 

9" Max.

  

10-1/2"

 

1-1/2"

to 34-3/4"

34-1/4"
to 34-3/4"

NOTE:

Handle and
handle standoff
depth is 2-1/8

FOR MODEL ZIDS240 WITH STAINLESS STEEL DRAWERS AND HANDLES

Clearance for Door

Opening 2-1/2" min.

Countertop

Double-Drawer

22" min.

Summary of Contents for monogram ZIDI240

Page 1: ...Design Guide with Installation Instructions Double Drawer Built In Refrigerator ZIDI240 ZIDS240 monogram com...

Page 2: ...s sont con us pour tre encastr s uniquement Ils ne peuvent pas tre s par s Il ne faut utiliser cet appareil que pour l usage pour lequel il a t construit Il faut r parer ou remplacer imm diatement tou...

Page 3: ...oduct into Cutout 8 Step 6 Set Temperature Controls 8 Important Information ZIDI240 MODEL ONLY PARTS REQUIRED Custom handles Overlay panels Spacer panels Backer panels Screws PARTS SUPPLIED Drawer sid...

Page 4: ...ent cabinetry Notify the installer if the drawers make contact with cabinetry Choose the location These products may be closed in on the top and three sides as long as the front is unobstructed for ai...

Page 5: ...allation Choose the location These products may be closed in on the top and three sides as long as the front is unobstructed for air circulation and proper access to the drawers Do not install these p...

Page 6: ...acker 23 3 16 14 11 16 0 10 Spacer 22 1 2 14 3 16 3 4 Overlay 23 5 8 15 1 16 6 STEP 1 REMOVE PACKAGING Remove corner blocks and foam drawer stops Remove all packing material tape and protective plasti...

Page 7: ...nd raise or lower the leveling legs Measure floor to countertop height inside the opening Adjust leveling legs until the product is approximately 1 8 less than countertop height INSTALLATION TIP Measu...

Page 8: ...r hands against the sides Be careful not to entangle power cord Check again to be sure the unit is level Adjust the leveling legs until the unit is resting firmly against the bottom of the counter to...

Reviews: