background image

2

Contents

Design Information

Models Available ......................................................... 3
Dimensions and Clearances ..................................... 3
Advance Planning ....................................................... 3
Advance Planning, Installation Options .................. 4
Tools and Materials Required ................................... 4

Installation Preparation

Cut the Opening ........................................................... 5
Power Supply Locations ............................................ 6

Before you begin—Read these instructions completely and carefully.

IMPORTANT:

 Save these instructions for local inspector’s use.

IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES.
NOTE TO INSTALLER:

 Be sure to leave these instructions with the Consumer.

NOTE TO CONSUMER:

 Keep these instructions with your Owners Manual

for future reference.

For Monogram local service in your area, call
1.800.444.1845.
For Monogram service in Canada, call
1.888.880.3030.
For Monogram Parts and Accessories, call
1.800.626.2002.

Proper installation is the responsibility of the
installer. Product failure due to improper
installation is not covered under the GE
Appliance Warranty. See the Owners Manual
for warranty information.

FOR YOUR SAFETY

If you smell gas:
1. Open windows.
2. Don’t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.

FOR YOUR SAFETY

Do not store or use combustible materials,
gasoline or other flammable vapors and
liquids in the vicinity of this or any other
appliance.

Natural Gas Installation Code, CAN/CGA-
B149.1 or the current Propane Installation
Code, CAN/CGA-B149.2, and with local
codes where applicable.

• This cooktop has been design-certified by

the American Gas Association according to
ANSI Z21.1, latest edition and Canadian Gas
Association according to CAN/CGA-1.1
latest edition.

• Your cooktop must be electrically grounded

in accordance with local codes or, in the
absence of local codes, in accordance with
the National Electrical Code (ANSI/NFPA
70, latest edition). In Canada, electrical
grounding must be in accordance with the
current CSA C22.1 Canadian Electrical Code
Part 1 and/or local codes.

• Installation of this cooktop must conform

with local codes, or in the absence of local
codes, with the National Fuel Gas Code,
ANSI Z223.1, latest edition. In Canada,
installation must conform with the current

Cet appareil doit être correctement mis à la terre. Voir << Alimentation
électrique >> à la page 6.

Installation

Install Cooktop ............................................................. 7
Install Pressure Regulator ......................................... 7
Connect Electrical ....................................................... 8
Assemble Burners, Check Ignition .......................... 8

Installation Option

Installation with Downdraft Vent ............................. 9
Installation with Warming Drawer ......................... 10
Installation with Single Oven .................................. 11

WARNING

This appliance must be properly grounded and with correct polarity.
See “Power Supply”, page 6.

ATTENTION

In the Commonwealth of Massachusetts:

• This product must be installed by a licensed plumber or gas fitter.
• When using ball type gas shut off valves, they shall be T-handle type.
• A flexible gas connector, when used, must not exceed 3 feet.

Summary of Contents for Monogram ZGU375LS

Page 1: ...Monogram If you have questions call 800 GE CARES or visit our website at www monogram com Installation Instructions 36 Stainless Steel Gas Cooktops Natural Gas Model ZGU375NS LP Gas Model ZGU375LS...

Page 2: ...CGA B149 1 or the current Propane Installation Code CAN CGA B149 2 and with local codes where applicable This cooktop has been design certified by the American Gas Association according to ANSI Z21 1...

Page 3: ...ching over heated surface units Working areas adjacent to the cooktop should have 18 minimum clearance between countertop and cabinet bottom Use the Monogram gas stainless steel cook top with any 36 o...

Page 4: ...nces The countertop must have a deep flat surface to accommodate the combined installation of the cooktop and vent The downdraft vent with blower motor and ductwork will occupy the base cabinet Consid...

Page 5: ...pace below countertop If installing cooktop above a cabinet with drawers it may be necessary to use a shorter length drawer to allow clearance for gas connection In some cases two 3 8 I D 45 elbows an...

Page 6: ...d in series with the manifold of the cooktop and must remain in series with the supply line regardless of type of gas being used The natural gas model is designed to operate at 5 water column pressure...

Page 7: ...regulator if local codes permit Appropriate flare nuts and adapters are required at each end of the flexible connector Turn on the gas Check for leaks using a liquid leak detector at all joints in the...

Page 8: ...turn 90 to HIGH position The igniter will spark and the burner will light the igniter will cease sparking when the burner is lit First test may require some time while air is flushed out of the gas li...

Page 9: ...valent length when bends or various fittings are used Again refer to Downdraft Vent Installation Instructions for details Power Supply If local codes permit the vent and cooktop may operate from the s...

Page 10: ...tion A 42 wide base cabinet should be used Narrow custom doors or decorative stiles can be used to fill the 6 gap on each side of the warming drawer 30 or 36 base cabinets are not recommended NOTE The...

Page 11: ...V power supply See page 6 Where codes permit the gas shut off valve may be located in an adjacent cabinet or other easily accessible location IMPORTANT Base Cabinet Requirements for Combined Installat...

Page 12: ...ions described in this book safety glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric T...

Reviews: