GE Monogram ZEU30R Installation Instructions Manual Download Page 7

Insert the wires from the conduit through the opening
of the junction box.

7

When making the wire connections, use the entire length of conduit provided. 

The conduit must not be

shortened.

Red

Black

Ground

wire

location

With the cooktop in place, open the front of the cabinet door.

Connect the red and black leads from the
cooktop conduit to the corresponding leads
in the junction box.

Red

Ground

Black

Strain

Relief

Clamp

Electrical Connections

Electronic Radiant Cooktop

Step    

1

Step

 2

Step

 3

Step   

4

GROUNDING INSTRUCTIONS
The bare ground wire in the conduit is connected to the cooktop frame. Effective January 1, 1996, the
National Electrical Code will not permit grounding through neutral. If used in new construction after
January 1, 1996 or in a mobile home, recreational vehicle or if local codes do not permit grounding
through the neutral white lead, attach the appliance grounding lead (green or copper) to the residence
grounding conductor (green or bare copper) in accordance with local codes. When connecting to a 3
conductor branch circuit, if local codes permit, connect the bare ground connector lead of the cooktop to
the branch circuit neutral (gray or white in color).
IMPORTANT: If the cooktop is being installed into a blind counter (one with no cabinet opening below),
wire connections must be made before putting the cooktop into the cutout opening.

Once the connections are made, secure wires
together using wire nuts.

Red

Black

Ground

Strain

Relief

Clamp

Step 

 5

NOTE: ALUMINUM WIRING

A. WARNING:

IMPROPER CONNECTION OF ALUMINUM HOUSE WIRING TO THE COPPER LEADS CAN
RESULT IN A SERIOUS PROBLEM.

B. Splice copper wires to aluminum wiring using special connectors designed and UL approved for joining

copper to aluminum and follow the manufacturer’s recommended connector procedure closely.

NOTE: Wire used, location and enclosure of splices, etc., must conform to good wiring practice and
local codes.

Summary of Contents for Monogram ZEU30R

Page 1: ...GE Monogram Installation Instructions 30 Electric Radiant Cooktop Model ZEU30R Monogram com ...

Page 2: ...4 1845 For Monogram Service in Canada 1 888 880 3030 For Monogram Parts and Accessories call 1 800 626 2002 Make sure the cabinets and wall coverings around the cooktop can withstand the temperatures up to 200 F generated by the cooktop The cooktop should be easy to reach and lighted with natural light during the day Always disconnect the electrical service to the cooktop before repairing or servi...

Page 3: ...n preparing the opening When installing your cooktop in your home make sure all local codes and ordinances are followed exactly as stated 3 Make sure the wall coverings countertop and cabinets around the cooktop can withstand heat up to 200 F generated by the cooktop ON HOT Literature Package Cooktop Styrofoam Packaging Design Information Electronic Radiant Cooktop Models Available ZEU30R Electron...

Page 4: ...verhead surface 1 1 2 MIN clearance from cutout to side wall on the right of the unit 13 MAX Depth of unprotected overhead cabinets 18 MIN height from countertop to nearest cabinet on either side of unit 6 1 4 5 1 2 3 1 4 Tools Materials Required 1 8 Drill Bit Electric or Hand Drill Phillips Head Screwdriver Pencil Ruler or Straightedge Wire Nuts Saber Saw Tools You Will Need Junction Box Material...

Page 5: ...Installation Electronic Radiant Cooktop Five inches 5 minimum vertical clearance between the cooktop bottom and any combustible surfaces Vertical Clearance To insure accuracy it is best to make a template when cutting the opening in the counter Make sure there is clearance inside the cabinet before cutting the countertop Make sure the wall coverings countertop and cabinets around the cooktop can w...

Page 6: ...IDES Installation Electronic Radiant Cooktop Apply the foam strips around the outer edge of the glass Do not overlap the foam strips Attach Foam Strips Foam Strips Bottom of Cooktop Cooktop Glass Remove the hold down brackets and screws from the literature package MOUNTING SCREW Locate Mounting Parts Screw the Hold Down Bracket to the side of the cooktop unit Repeat for opposite side of cooktop At...

Page 7: ...e lead attach the appliance grounding lead green or copper to the residence grounding conductor green or bare copper in accordance with local codes When connecting to a 3 conductor branch circuit if local codes permit connect the bare ground connector lead of the cooktop to the branch circuit neutral gray or white in color IMPORTANT If the cooktop is being installed into a blind counter one with n...

Page 8: ...eads supplied with this appliance are UL recognized for connections to larger gauge household wiring The insulation of these leads is rated at temperatures much higher than the temperature rating of household wiring The current carrying capacity of a conductor is governed by the wire gauge and also the temperature rating of the insulation around the wire NOTE While performing installations describ...

Reviews: