Design Guide

THE INSTALLATION SPACE

  *For a standard installation:

 The product must be installed 

so that the front face will project 1-3/4" forward of adjacent 
cabinets. This position will allow a full door swing and prevent 
interference with adjacent cabinetry. The opening between 
cabinets must be 23-3/4" minimum.

**For a flush installation:

 Install a 1/2"-wide filler strip on the 

hinge side. The filler strip will act as a spacer between the 
door case and adjacent cabinets and will prevent interference 
with the cabinet door swing. Recess the filler strip 1-3/4" back 
from the front face of the unit, or even with the front edge 
of the product case (behind the gasket). The width of the 
opening must be 24-1/4" (including the 1/2" filler strip).

• The wine reserve and beverage center can be installed 

freestanding.

Additional Specifications

• A 120 volt 60Hz., 15 or 20 amp power supply is 

required. An individual properly grounded branch 
circuit or circuit breaker is recommended. Install a 
properly grounded 3-prong electrical receptacle 
recessed into the back wall as shown. Electrical must 
be located on rear wall as shown. 

NOTE: 

GFI (ground 

fault interrupter) is not recommended.

THE INSTALLATION SPACE (cont.)

3

NOTE: 

 

Handle and handle 

standoff depth is 1-3/4"

These products will fit flush 

to adjacent cabinets when 

installed with a 1/2" filler panel 

or cleat. The filler panel should 

be recessed or set back behind 

the door and even with the front 

edge of the product case.

In a standard installation,  

the product will project 1-3/4" 

forward of adjacent cabinets.

Flush 

Installation

CABINET

CABINET

CABINET

CABINET

1-3/4"

1/2"

120°

120°

110°

110°

Filler panel or cleat 

to be set back even 

with front of case.

Front edge of product case

Front face

Front face

Front edge of product case

Standard  

Installation