GE Monogram ZBD6400 Series Installation Instructions Manual Download Page 7

Installation Preparation

7

PREPARE ELECTRICAL WIRING

FOR PERSONAL SAFETY: Remove
house fuse or open circuit breaker
before beginning installation. Do not use
an extension cord or adapter plug with
this appliance.

Electrical Requirements

• This appliance must be supplied with 120V, 60 Hz., and
connected to an individual properly grounded branch
circuit, protected by a 15 or 20 ampere circuit breaker or
time delay fuse.
• Wiring must be 2 wire with ground and rated for 75

°

C

(176

°

F).

• If the electrical supply does not meet the above require-
ments, call a licensed electrician before proceeding.

Grounding Instructions–Cable Direct

This appliance must be connected to a grounded metal
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and be
connected to the equipment-grounding terminal or lead
on the appliance.

Grounding Instructions–Power Cord

This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk
of electrical shock by providing a path of least resistance
for electric current. The plug must be plugged into an
appropriate outlet that is installed and grounded in
accordance with all local codes and ordinances.

The improper connection of the equip-
ment-grounding conductor can result in
a risk of electric shock. Check with a
qualified electrician or service represen-
tative if you are in doubt that the appli-
ance is properly grounded.

Electrical Connections to Dishwasher:

The dishwasher junction box is located on the right side
at the front of the dishwasher. The electrical cable must
extend forward at least 24” to reach the junction box
when dishwasher is installed.
• The wiring may enter the opening from either side,

rear or the floor within the shaded area.

• Cut a 1-1/2” max. dia. hole to admit the electrical

cable or use the same hole cut for the drain hose. The
hole must be free of sharp edges. If the cabinet wall is
metal, the hole edge must be covered with a bushing.

• For power cord connections, install a 3-prong ground-

ing type receptacle in the sink cabinet rear wall, 6"
min, or 18" max. from the opening, and 6" to 18"
above the floor.

White

18"

6"

24"

from Wall

3"

from

Cabinet

Alternate
Receptacle
Location

Ground

Black

1-1/2" Dia. Hole (Max.)

18"

6"

2"

Receptacle
Location
Area

2"

POUR ASSURER LA SÉCURITÉ
PERSONNELLE, il faut enlever le fusible
ou couper le courant au disjoncteur
avant de commencer l’installation. Avec
cet appareil, il ne faut pas utiliser de
rallonge ni d’adaptateur de prise.

AVERTISSEMENT

Le mauvais branchement du fil de mise à
la terre de l’équipement peut causer un
choc électrique. En cas de doute sur la
mise à la terre de l’appareil, consulter un
électricien qualifié ou un représentant
technique.

AVERTISSEMENT

Summary of Contents for Monogram ZBD6400 Series

Page 1: ...ons call 800 626 2000 or visit our website at www monogram com Installation Instructions Built In Dishwashers ZBD6400 ZBD6500 ZBD6600 ZBD6700 ZBD6900 ZBD7000 ZBD7100 Chef s Washers ZBD6605 ZBD6905 ZBD...

Page 2: ...installer Product failure due to improper installation is not covered under the GE Appliance Warranty Completion Time 1 to 2 Hours New installa tions require more time than replacement installa tions...

Page 3: ...the front leveling legs The rear legs should be screwed in flush with the bottom support as shipped The front of the dishwasher must be shimmed to level the dishwasher Water and electrical must be rou...

Page 4: ...ure and pressure Coupler for extending drain line if applicable 4 90 Elbow Thread Seal Tape Wire Nuts Screw Type Clamps Waste Tee Shut Off Valve Electrical Cable or Power Cord Air Gap Coupler Hot Wate...

Page 5: ...by removing front leveling legs Drain hose water and electrical must be routed through the cutout on the back of the dishwasher The dishwasher must be installed so that drain hose is no more than 10 f...

Page 6: ...h Drain Loop with Waste Tee or Disposer Install waste tee or disposer and air gap according to manufacturer s instructions CABINET PREPARATION Drill a 1 1 2 dia hole in the cabinet wall within the sha...

Page 7: ...ng conductor can result in a risk of electric shock Check with a qualified electrician or service represen tative if you are in doubt that the appli ance is properly grounded Electrical Connections to...

Page 8: ...er the sink Optional but strongly recommended and may be required by local codes The hot water line should be 3 8 O D copper tubing or 1 2 O D plastic tubing The line must extend forward at least 30 f...

Page 9: ...l height 1 Measure dimension A from the underside of the countertop to the bottom of adjacent cabinets 2 Subtract 1 4 This allows a 1 4 clearance gap between the underside of the countertop and the to...

Page 10: ...countertop Install the front leveling legs into holes on the brack ets Use a wrench to screw the legs in until the overall height of the dishwasher is 1 4 less than the installa tion opening height N...

Page 11: ...SLIDE DISHWASHER INTO OPENING DO NOT PUSH AGAINST THE FRONT PANEL WITH KNEES DAMAGE WILL OCCUR Insert drain hose into the cabinet wall hole If a power cord is used guide the end through a separate ho...

Page 12: ...Use wire connectors to connect incoming ground to green white to white and black to black Install junction box cover with screws provided Check to be sure that wires are not pinched under the cover Re...

Page 13: ...el and door Verify water supply and drain lines are not kinked or in contact with other components Turn on the sink hot water faucet and verify water temperature Incoming water temperature must be bet...

Page 14: ...K Loosen depth adjustment screws inside the bracket Slide bracket out to proper depth Tighten screws Attach supplied toekick to brackets with screws C provided Do not tighten Adjust the toekick to tou...

Page 15: ...washer will slip into the keyhole slots on the dish washer door Screw Shoulder Washer Place shoulder washer over one hole and drive the supplied 8 x 1 2 Phillips pan head wood screws into the panel In...

Page 16: ...al service in your area call 1 800 444 1845 Note Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice...

Reviews: