Table 3-6 provides insight on the causes of events that inhibit the unit from operating, and possible correc-
tive actions. The Event Log Entry column shows the text that appears in the Description column on the
Event
Log
screen.
EVENT_MACADDR
MAC Address Invalid
noMacAddress(6)
EVENT_NETNAME
*
Netname Invalid
invalidNetname(12)
EVENT_NO_CHAN*
Using Channel hopping
but no channels
selected
NoChan(23)
EVENT_PLL_LOCK
PLL Not locked
pllLock(10)
EVENT_POWER_CAL
Power Calibrated/Not
Calibrated
powerCal(8)
EVENT_POWER_HIGH
RF Power Control
Saturated High
rfPowerHigh(13)
EVENT_POWER_LOW
RF Power Control
Saturated Low
rfPowerLow(14)
EVENT_REDUNDANCY_
SWITCH
Redundancy
Switchover Set
redundancySwitch(24)
EVENT_RSSI
*
RSSI Exceeds
threshold
rssi(11)
EVENT_RSSI_CAL
RSSI Not Calibrated
rssiCal(9)
EVENT_SYSTEM_ERROR*
System Error Cleared;
Please Reboot
systemError(16)
Table 3-6. Correcting Alarm Conditions—Alphabetical Order
Event Log Entry
Generating Condition
Clearing Condition
or Action
Ethernet Rate
Above 50, 75,
100%
Data on the Ethernet port has
reached the % value of the
configured Ethernet Rate
Limit.
Reduce traffic on network,
unplug Ethernet cable from
radio.
ADC Output Railed
The ADC always reads the
same value (either high or
low limit)
Contact factory Technical
Services for assistance
AP Ethernet Link
Disconnected
Monitor will check state of
Ethernet link and set alarm if
it finds the link down
Ethernet link is re-established
Channels Not
Programmed
No channels programmed.
Configure channels.
Flash Test Failed
Internal check indicates
corruption of Flash memory
Contact factory Technical
Services for assistance
FPGA
communication
Failed
Communication lost to the
FPGA
Contact factory Technical
Services for assistance
Table 3-5. Alarm/Event Conditions (Alphabetical Order)(Continued)
Alarm Condition Reported
Event Log Entry
SNMP Trap
Summary of Contents for MDS iNET Series
Page 12: ...x MDS iNET Series Reference Manual 05 2806A01 Rev L...
Page 159: ...05 2806A01 Rev L MDS iNET Series Reference Manual 147 Figure A 22 EDS Wizard Completion Screen...
Page 165: ...05 2806A01 Rev L MDS iNET Series Reference Manual 153 NOTES...
Page 166: ...154 MDS iNET Series Reference Manual 05 2806A01 Rev L NOTES...