MDS SDA Instruction Sheet

Technical Support: +1 585 241-5510

05-6398A01, Rev. A

FAX: +1 585 242-8369

September 2014

Web: www.gemds.com

5.1

Pin Descriptions—RS-232 Mode

Pin descriptions for the COM connector in RS-232 mode are 
shown in 

Figure

 

8

 and 

Table

 

5

. Note that the unit is hardwired as 

a DCE device. Refer to the Technical Manual for RS-422/485 
descriptions. 

(Note: RS-485 supported on COM1 only.)

1 2 3 4 5 6 7 8

Figure 8. COM Connector (RJ-45)

As viewed from outside the unit

Table 5: COM1/COM2 Pinouts—RS-232

 

 

Pin 
#

Input/ 
Output

Pin Description

6.0

ALARM/AUDIO PINOUT

The ALARM/AUDIO Interface on the Alarm/Relay module provides 
audio signaling and alarm outputs as shown below. 

Invisible 

place 

holder

Figure 9. Alarm/Audio Connections

(As viewed from outside the radio)

7.0

TROUBLESHOOTING

If trouble occurs with the unit, verify that it meets the basic require-
ments listed below. These items should be checked prior to 
starting any detailed troubleshooting or calling for assistance. All 
units must have: 

• Adequate and stable primary power
• Secure cable and wiring connections
• Proper configuration for the application 

7.1

LEDs

The LEDs on the front of installed modules (

Table

 

4

) provide useful 

information when troubleshooting. Power and alarm indicators are 
provided on Platform Manager, Radio, and Alarm/Relay modules. 
Radio Modules also have TX/RX LEDs to show wireless activity.

7.2

Redundant Units

The active radio can be identified by the corresponding LED on the 
alarm/relay module as well as the active LED on the radio module. 
The active unit is normally selected automatically. For trouble-
shooting, the toggle switch can be used to manually set the active 
radio. Alternatively, the switch can remain in the automatic posi-
tion, and the active radio can be selected via the SD Manager UI.

7.3

Technical Assistance

Factory technical assistance is available by contacting GE MDS 
during business hours (8:30 AM to 6:00 PM Eastern Time). For 
telephone assistance, call (585) 241-5510, or visit our website at 
www.gemds.com for additional contact options.

Refer also to the 

Regulatory & Product Information Sheet

 supplied 

with these instructions.

1

Reserved

-- (Do not connect)

2

OUT

DCD (Data Carrier Detect)

3

Reserved

-- (Do not connect)

4

Ground

Connects to chassis ground (negative supply)

5

OUT

RXD (Received Data)—Supplies received data 
to the connected device

6

IN

TXD (Transmitted Data)—Accepts TX data 
from the connected device

7

OUT

CTS (Clear to Send)

8

IN

RTS (Request to Send)