4 |
GE Oil & Gas
2. TYPE 12400 NUMBER SYSTEM
12
4
a
b
c
d
Model
Action
Mounting
Protection
Housing
Material
4 -
HAR
T c
om
m
un
icat
ion
p
ro
to
col
,
LC
D
d
is
pla
y a
nd
pu
sh
bu
tt
on
s,
S
IL
c
er
tif
ie
d
1 – Controller with
adjustable
switches and
second 4-20 mA
analogue output
signal:
AO_1, AO_2,
DO_1, DO_2
2 – Transmitter:
AO_1
3 – Transmitter
with adjustable
switches and
second 4-20 mA
analogue output
signal:
AO_1, AO_2,
DO_1, DO_2
O - Top and bottom,
Screwed, BW or SW
1 - Top and bottom,
Flanged
2 - Side and side,
Flanged
3 - Top vessel,
Flanged
4 - Side vessel,
Flanged
5 - Top and side,
Screwed, BW or SW
6 - Side and bottom,
Screwed, BW or SW
7 - Side and bottom,
Flanged
8 - Top and side,
Flanged
9 - Side and side,
Screwed BW or SW
1 - FM & FMc
SI, NI, DIP, XP and
Nema 4X-6P
2 - JIS, Xproof
3 - Rosteknadzor,
IS, Xproof
and IP 66/67
4 - Inmetro,
IS, Xproof
5 - ATEX & IECEx
IS, Xproof,
and IP 66/67
6 - Others approvals
(based on ATEX/IEC
approvals)
7 - Other approvals
(not based on ATEX/
IEC approvals)
1- Aluminum with
epoxy painting
2 - Stainless steel
Note: Controller option is pending. Please consult GE Oil & Gas.
3. TECHNICAL SPECIFICATIONS
3.1 Performances
Refer to specific gravities between 0.15 and 1.4 with a standard displacer 907 cm
3
@ 1362 g.
• Accuracy : ± 0.5 %
• Hysteresis : ± 0.3 %
• Repeatability : ± 0.2 %
• Dead zone: ± 0.1 %
• Ambient temperature ranges:
• In operation : -50°C to + 80°C
• Storage and transport: -50°C to +93°C
• Water ingress protection: IP66/67