TOOLS YOU WILL NEED

2

Installation Instructions

❒ 

#2 Phillips Screwdriver

❒ 

Tape Measure

❒ 

Drill with 7/64

Bit or #35

❒ 

Scissors (Optional)

❒ 

Pencil

❒ 

Awl or Punch

❒ 

CUTOUT DIMENSIONS

WARNING 

— This trim kit uses air flow

from the top, bottom and sides of the trim frame.
Blocking the air flow can cause the microwave to
function improperly and may cause damage to
the microwave.

Allow a 1

clearance beyond the edge of the trim

frame to provide proper air flow.

1

Depth

Height

1

1

2

Overlap 

Width

1

1

2

Overlap 

1

Clearance beyond

trim frame

(on all sides)

3

Min.

27

Models: 1

1

2

overlap

30

Models: 3

overlap

❒ 

CUTOUT DIMENSIONS

(CONT.)

On 27

models, allow 1

1

2

on all sides for overlap 

of the trim frame over the edges of the cutout.

On 30

models, allow 1

1

2

at the top and bottom

and 3

″ 

on each side for overlap of the trim frame

over the edges of the cutout.

FOR INSTALLATION ABOVE A BUILT-IN OVEN:

Microwave oven should be installed on a 3/8

plywood base and supported by 2x4 or 1x2
equivalent runners on all sides. Base must be capable
of supporting a minimum of 100 lbs (45.3 kg).

1

* Min. depth with 120V–60 Hertz grounded power

receptacle outside cabinet 21

1

2

Min. depth with 120V–60 Hertz grounded power
receptacle inside cabinet 23

Models

27

30

Height

18

3

4

18

3

4

Width

24

±

1

16

24

±

1

16

Depth (min.)*

21

1

2

or 23

21

1

2

or 23

❒ 

INSTALL THE ANTI-TIP BRACE

Draw a line on the cutout floor at the center of
the cutout, and extend the line 1/2

down the

face of the cabinet.

Fold or cut the front edge of the template,
along the front guide line. Place the template
flush along the front edge of the cutout floor,
aligning the center line of the template with the
center line of the cutout floor. Mark the centers
of the two screw holes with an awl or center
punch for the anti-tip brace location as shown.

Remove the
template and drill
two holes for the
anti-tip brace.

Install the anti-tip
brace onto the
cutout floor using
two round-head
screws.

D

C

B

A

2

Round-Head

Screws

Anti-Tip
Brace

Cutout
Floor

Center
Line

B

A

C

DIMENSIONS:

A = 

13

16

B = 3

C = 20

1

16

❒ 

Level

Bottom of trim kit must be 
minimum of 36

from floor

1

= 0.3 m

1

= 2.5 cm

Summary of Contents for JX1527CBH

Page 1: ...e to improper installation is not covered under the Warranty This kit is UL CSA listed for installation alone or over any GE GE Profile single electric wall oven Not for use adjacent to within 2 feet of any gas or electric range cooktop or oven For easier installation and personal safety we recommend that two people install this microwave oven Unplug the microwave oven before attempting installati...

Page 2: ...2x4 or 1x2 equivalent runners on all sides Base must be capable of supporting a minimum of 100 lbs 45 3 kg 1 Min depth with 120V 60 Hertz grounded power receptacle outside cabinet 211 2 Min depth with 120V 60 Hertz grounded power receptacle inside cabinet 23 Models 27 30 Height 183 4 183 4 Width 24 1 16 24 1 16 Depth min 211 2 or 23 211 2 or 23 INSTALL THE ANTI TIP BRACE Draw a line on the cutout ...

Page 3: ...hesive backing from the upper duct and secure it to the microwave oven by pressing it firmly down on duct Fasten the upper duct with the two screws just removed from the microwave oven Place the top bracket on top of the upper duct with the opening on the top bracket lined up with the opening on the duct Attach the top bracket to the upper duct using two round head screws B A 4 Microwave oven upsi...

Page 4: ...t openings at the bottom Press the trim frame into the opening until all sides snap into place Open the microwave oven door Secure the trim frame using four flat head screws two on the inside top and two on the inside bottom C B A 8 REPLACE ANY LOOSE ITEMS Your trim kit is now fully installed Replace the turntable and turntable support that were removed from the inside of the microwave oven Keep t...

Page 5: ...auvaise installation n est pas couverte par la garantie Cet ensemble est homologué CSA UL pour une installation seule ou combinée avec un four encastré électrique simple GE ou GE Profile Ce four à micro ondes ne peut être installé à moins de 2 pieds d une cuisinière au gaz ou électrique d une surface de cuisson ou d un four Pour une installation plus facile et votre propre sécurité nous recommando...

Page 6: ...minimale de 100 lb 45 3 kg Profondeur min avec prise mise à la terre de 120 V et 60 Hz à l extérieur de l ouverture 211 2 po Profondeur min avec prise mise à la terre de 120 V et 60 Hz à l intérieur de l ouverture 23 po Modèles 27 po 30 po Hauteur 183 4 po 183 4 po Largeur 24 1 16 po 24 1 16 po Profondeur min 211 2 ou 23 po 211 2 ou 23 po MONTAGE DU RENFORT DU SUPPORT ANTIBASCULEMENT Tracez une li...

Page 7: ...four à micro ondes Retirez l une des vis de la caisse du four à micro ondes Placez le conduit inférieur sur la partie inférieure du four à micro ondes et fixez le au moyen de six vis à tête ronde et de la vis retirée précédemment du four à micro ondes Retournez le four en orientant le côté droit vers le haut et en vous assurant que le rebord du conduit inférieur ne fléchit pas Support antibasculem...

Page 8: ... ouverture jusqu à ce que tous les côtés s enclenchent en position Ouvrez la porte du four à micro ondes Fixez le cadre de finition avec quatre vis à tête plate deux à l intérieur et au haut et deux à l intérieur et au bas REMISE EN PLACE DE TOUTES LES PIÈCES MOBILES Votre cadre de finition est maintenant installé Remettez le plateau tournant et le support du plateau tournant à l intérieur du four...

Reviews: