7-16
COMPONENTS TEST
PROCEDURES
RESULTS
HIGH-VOLTAGE
CAPACITOR
HIGH-VOLTAGE
DIODE
CONVECTION
HEATER
1. Remove wire leads.
2. Measure resistance. (ohm meter scale:
Rx1000)
(1) Terminal to terminal
(2) Terminal to case
1. Measure continuity. Forward.
(ohm meter scale: Rx1000)
1. Measure continuity. Reverse.
(ohm meter scale: Rx1000)
1. Remove wire leads.
2. Measure resistance.
(ohm meter
scale:Rx1)
Normal:
Momentarily indicates several ohm, and
then gradually returns to infinite
Normal: Infinite.
Normal:Continuity.
Abnormal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
Normal readings
Resistance: Approx. 6 to 13 ohm
Current: Approx. 13A
Abnormal: Infinite or several.
Ohm-meter
Figure 25-a
Ohm-meter
Figure 25-b
Ohm-meter
Figure 26-a
Ohm-meter
Figure 26-b