MINIMUM CLEARANCES 

(CONT.)

MINIMUM DIMENSIONS BETWEEN

COOKTOP AND CABINETS OR WALLS

Electrical Outlet Area

(Back of counter in cutout not shown for clarity)

The distance from the floor to the top 
of the counter must be at least 35-7/8

The maximum countertop height is 38

.

Make sure the wall coverings, countertop and
cabinets around the cooktop can withstand
the heat (up to 200°F) generated by the range. 

NOTE:

Dimension for Wall to Front of Door

Handle (door closed).

*28

FOR MODELS – JSP26, JSS26, JSC26,

JSS16, RS734, RS504

**28-1/2

FOR MODELS – JSP39, JSP38, JSP31,

JSP28, RS744, RS622, JS960, JSP40, JSP34

3

3

Installation Instructions

MINIMUM CLEARANCES 

The distance from the floor to the top 
of the counter must be at least 35-7/8

The maximum counter height is 38

30

ranges conform to U.L. requirements 

for 0

spacing from vertical walls above

countertops. However, some kitchen cabinet
finishes can be damaged by heat from the
range surface elements. Where varnished
wood or plastic film finishes are used, 
a minimum clearance of 6

must be

maintained. 

For listed over-the-range microwave 
ovens, the microwave ovens can be
installed above the cooktop as per
manufacturer’s installation instructions. 

The range may be placed with 0

clearance

(flush) at the back wall and side walls if the
range side trims extend beyond the cabinet
fronts at least 1/4

See Figures 1 and 2 for all rough-in and
spacing dimensions. These dimensions
must be met for safe use of your range. 
The location of the electrical outlet may 
be changed as needed, but electricity to 
the range can be disconnected at the outlet
without moving the range if the outlet is 
in the suggested location (remove lower
drawer). 

3

ANTI-TIP DEVICE INSTALLATION

(CONT.)

Slip the nearest link of the chain onto the
bracket. Pull to make sure it is as snug as
possible. 

Slide the range all the way back. It is
normal to have some slack in the chain,
but it should not be excessive. 

I

H

2

0”

18” Min.

30” Min.

0”

6”

Min.

6”

4

1

2

2

1

4

30”

36”

30”

Acceptable
electrical
outlet area. 

Backguard (some models)

Mainback

Bracket Optional
Location

Chain

Bracket Factory
Location

28

1

2

”** Wall to front

of door handle
(door closed) 45”
with door open

Fig. 5

Fig. 6

Fig. 7

28”*

1

4

5”

Summary of Contents for JSP26

Page 1: ...his appliance must be properly grounded FOR YOUR SAFETY CAUTION For Personal Safety remove house fuse or open circuit breaker before beginning installation Failure to do so could result in serious inj...

Page 2: ...und inside the prepack of the oven and save packaging tape 1 ANTI TIP DEVICE INSTALLATION Before placing range in the counter check the factory location of the stability device on the back of the rang...

Page 3: ...a minimum clearance of 6 must be maintained For listed over the range microwave ovens the microwave ovens can be installed above the cooktop as per manufacturer s installation instructions The range...

Page 4: ...chrome JXS33 almond JXS34 black or JXS35 bisque or a Main Top Rear Filler Kit Model JXS62BB black JXS63WW white JXS64AA almond or JXS65CC bisque These kits are available through your GE dealer if the...

Page 5: ...1 is greater than the standard 1 1 8 there will be a small gap between the wall behind the range and the backguard This is normal and should not be visually objectionable 5 SIDE TRIM EXTENSION KIT If...

Page 6: ...sion cord with this appliance Remove house fuse or open circuit breaker before beginning installation This appliance must be supplied with the proper voltage and frequency and connected to an individu...

Page 7: ...installed before reinstalling the rear range wiring cover Skip to applicable power cord installation 1 Power cord Strain relief Terminal block Bracket CONDUIT AND SQUEEZE CONNECTOR INSTALLATION For c...

Page 8: ...s securely into the terminal block Re intall the junction block access cover making sure that wires do not become pinched between wire cover and mainback E D C B A 4 3 WIRE POWER CORD INSTALLATION WAR...

Page 9: ...pinched between wire cover and mainback B A 5 4 WIRE CONDUIT INSTALLATION Loosen the three lower terminal screws from the terminal block Remove the ground screw and ground plate and retain them Cut a...

Page 10: ...in cutout until you are sure that the flanges below the sides of the cooktop are above the top of the counter Lift cooktop to see flanges Damage to the cooktop could result if adjusted improperly Inst...

Page 11: ...he following is a suggested method of making a filler for the toe space when the legs are extended as mentioned before After the range is installed with the longer legs and is in position and level me...

Page 12: ...12 Notes Printed in the United States...