Summary of Contents for jgp336wev2ww

Page 1: ...r dance with local codes or in their absence with the National Electrical Code ANSI NFPA No 70 Latest Edition See Grounding Instructions on page 6 In Canada electrical grounding must be in accor dance with the current CSA C22 1 Canadian Electrical Code Part 1 and or local codes See Electrical Connec tions Be sure the installation of this cooktop in a mobile home conforms with the Manufactured Home...

Page 2: ... designed to operate on natural gas at 4 of water column pressure It is shipped from the factory set for natural gas FOR PROPER OPERATION THE MAXIMUM INLET PRESSURE TO THE REGULATOR MUST BE NO MORE THAN 14 OF WATER COLUMN PRESSURE For checking the regulator the inlet pressure must be at least 1 or 3 4 KPA greater than the regulator output setting If the regulator is set for 4 of water column press...

Page 3: ...djust the Pressure Regulator by CAP GASKET otiy SPRING RETAINER 8am9B LP PROPANE POSITION I I F A i I I t I I I I I I I I i I JJ l 0 1 I L l PRESSURE REGULATOR A Unscrew the cap B Place your thumb against the flat side of the spring retainer and press down to remove the retainer C Careftiy look at the spring retainer to locate the NAT or L P propane position D Turn the spring retainer over so that...

Page 4: ...P Propane orifices are shipped in the literature package They will have a digit number and the letter L on one side Each orifice will also show a series of engraved marks I 11 or III located on the top These marks denote the precise location of each orifice to the cooktop burner o 0 1 o 0 1 GLASS COOKTOP 6 Install the L P Propane orifices in their precise locations PORCELAIN COOKTOP SPECIAL NOTE A...

Page 5: ...ld pipe has not been moved A misalignment could cause the valve knob stem to rub on the control panel resulting in a gas leak at the valve Disconnect this range and its individual shutoff valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig Isolate the range from the gas supply piping system by closing its individual shut off va...

Page 6: ...PTACLE IS GROUNDED THROUGH THE HOUSE WIRING THE CUSlX3MER SHOULD HAVE THE CIRCUIT CHECKED BY A QUALIFIED ELECTRICIAN IX3 MAKE SURE THE RECEPTACLE IS PROPERLY GROUNDED When disconnecting the power cord from the adaptor always hold the adaptor with one hand If this is not done the adaptor ground terminal is very likely to break with repeated use Should this happen DO NOT USE the appliance until a pr...

Page 7: ...ach valve separately until all burners have been checked out BURNER IGNITION COOKTOP SPARK IGNITION When you turn the cooktop knob to LITE the spark igniter makes a series of electric sparks ticking sounds which light the burner During a power fa lure the burners will not light automatically In an emergency a cooktop burner may be lit with a match by following the steps below 1 Light a match and h...

Page 8: ...Pub No 31 10172 229c4053p038 i NOTES 8 RecycledPaper Printed in LaFayette Georgia ...