8
Operating Instructions
Safety Instructions
Care and Cleaning
Troubleshooting T
ips
Consumer Support
Before Lighting the Grill
■
The grill must be assembled in
accordance with the Assembly
Instructions.
■
Check that your LP tank is full and
properly connected to the regulator.
■
Check that there are no gas leaks in
the gas supply system. See the Leak
Testing section.
■
Check that the venturi tubes are properly
located over the gas valve orifices.
■
Check that both Main Burner and Side
Burner ignition wires are connected.
■
Read carefully all instructions contained
on the rating plate.
CAUTION:
Check your grill
after lighting. All the ports on the burner
should show a 1
″
(2.5 cm) flame on HI
setting.
■
If any of the following symptoms occur,
there is probably a blockage in the
venturi tubes. Shut off gas at once and
clean the venturi tubes. See the Venturi
tubes section.
1. You smell gas.
2. If a flashback fire occurs.
3. Your grill heats unevenly.
4. The burners make popping noises.
TO LIGHT WITH THE IGNITOR:
1.
Make sure control knobs are set to
OFF
and turn on the gas supply by
opening the LP tank valve.
2.
Push and turn right control knob
to
HI
.
3.
Push the ignitor button 3 or 4 times.
The burner should ignite within
4 seconds.
After the right burner is lit, push
and turn left control knob to
HI
.
Left burner will ignite automatically.
TO LIGHT WITH A MATCH:
1.
Make sure control knobs are set to
OFF
and turn on the gas supply by
opening the LP tank valve.
2.
Insert lighted match through lighting
hole located at the bottom right of the
grill housing.
3.
Push and turn right control knob to
HI
. The burner should ignite within
4 seconds.
After the right burner is lit, push
and turn left control knob to
HI
.
Left burner will ignite automatically.
Check Flame
Burner
Burner Port
HI
OFF
IGNITOR
LEFT
LO
HI
OFF
RIGHT
LO
Lighting the grill.
Lighting the Main Burners
WARNING:
Open lid before lighting.
If the Main Burner Will Not Light
1.
Turn control knobs to
OFF
.
Wait 5 minutes, then try again.
2.
If any burner will not light, consult
the
Troubleshooting Tips
section at
the back of this manual. If problem
cannot be resolved, do not attempt
to operate the grill. Contact a
GE Authorized Service Center.
Shutting Down
1.
Turn off the gas supply by closing
the LP tank valve.
2.
Turn control knobs to
OFF
.