INSTALLATION INSTRUCTIONS
STEP
3 WIRE POWER CORD INSTALLATION
Remove the 3 wire terminal screws from
the connector block. Insert screws through
each power cord terminal ring and into the
connector block until the screws engage the
nuts. Be certain that the center wire is connected
to the center screw of the connector block.
Tighten screws securely. Do NOT remove
ground strap connection.
CONNECTOR
NEUT
K
TERM
D
POWER
WARNING: THE NEUTRAL OR GROUND
WIRE OF THE POWER CORD
CONNECI’ED TO THE NEUTRAL
TERMINAL LOCATED IN THE CENTER OF
THE CONNECTOR BLOCK. THE POWER
LEADS MUST BE CONNECI’ED TO THE
OUTSIDE (BRASS COLORED) TERMINALS.
STEP
4
WIRE POWER CORD INSTALLATION
A.
Remove the 3 screws
the connector
block.
B.
Remove the grounding screw and strap from
connector block middle location and the
screw connection to the frame the range.
BEFORE
NEUTRAL
TERMINAL
GROUNDING STRAP
(GROUNDING TO RANGE)
screws through each power cord
terminal ring and into connector block until
screw engages nut.
certain that the center
wire is connected to the center screw the
connector block. Tighten screws securely.
D.
Attach ground wire to the frame of the range.
AFTER
I
GROUNDING
TO RANGE
CIRCUIT IS CONNECTED
THE NEUTRAL
TERMINAL LOCATED
CENTER OF THE CONNECTOR
BLOCK. THE POWER LEADS MUST
CONNECTED TO THE OUTSIDE
(BRASS COLORED) TERMINALS. THE
4TH GROUNDING LEAD MUST BE
CONNECTED TO THE
OF THE
RANGE
THE
SCREW.