background image

Help us
help you...

Before using your
air conditioner, read
this book carefully.

It is intended to help you operate
and maintain your new air
conditioner properly.

Keep it handy for answers to your
questions.

If you don’t understand something
or need more help, write (include
your phone number):
Consumer Affairs
GE Appliances
Appliance Park
Louisville, KY 40225

Write down the 
and serial numbers.

You’ll find them on a label behind
the room cabinet.

These numbers are also on the
Consumer Product Ownership
Registration Card that came with
your air conditioner. Before sending
in this card, please write these
numbers here:

Model Number

Serial Number

Use these numbers in any
correspondence or service calls
concerning your air conditioner.

If you received a damaged air
conditioner, 

immediately contact

the dealer (or builder) that sold
you the air conditioner.

 Safety

Read 

 instructions before

 this appliance.

When using this appliance, always
exercise basic safety precautions,
including the following:

● 

Use this appliance only for 

intended purpose 

as 

 in

this Use and Care Book.

● 

This air conditioner must be

properly installed in accordance
with the Installation Instructions
before it is used.

● 

Never use an extension cord

with this appliance.

 Unplug your air conditioner

before making any repairs.

Note: We strongly recommend that
any servicing be performed by a
qualified individual.

● 

For your safety . . . 

Do not store or

use combustible materials, gasoline
or other flammable vapors or
liquids in the vicinity of this or any
other appliance.

SAVE 

Energy-Saving
Tips

● 

Keep the air filter clean. (See

instructions on page 5.)

● 

For most efficient operation,

keep vent in closed position except
when you want to let outside air
enter the room.

● 

Don’t let the room get too hot or

too cold. Whenever possible, turn
the unit on before the room heats
up or cools off. If you don’t, the air
conditioner will take longer to
produce the desired comfort
condition.

. Keep windows and doors closed.

Conditioned air escapes when
they’re open.

● 

Keep furnace floor registers and

cold air returns closed when cooling
is desired. Conditioned air can
easily escape through them.

● 

Don’t let drapes or furniture block

the front of the unit and restrict air
flow when it is operating.

. It’s best to operate your air

conditioner at high speed during
extremely hot or cold weather.

● 

Keep the outdoor condenser coil

clean. (See page 5.)

● 

Turn the air conditioner off

before vacations or extended

absences.

Save time and money.
Before you request service,

check the Problem Solver on
page 6. It lists causes of minor
operating problems that you
can correct yourself.

2

Summary of Contents for Heat Pump Zoneline 2700 Series

Page 1: ...r Coils 5 Energy Saving Tips 2 Fan Cycle Switch 4 Master Controls 3 Model and Serial Numbers 2 Problem Solver 6 Repair Service 7 Room Cabinet and Case 5 Safety Instructions 2 Thermostat Control 3 Ventilation Control 4 Warranty Back Cover GEAmwer CenteP 80 6262000 Heat Pump Zoneline Model 2700 Series GEAppBances ...

Page 2: ...ver use an extension cord with this appliance 6 Unplug your air conditioner before making any repairs Note We strongly recommend that any servicing be performed by a qualified individual For your safety Do not store or use combustible materials gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance SAVE THWE STRUCTIONS Energy Saving Tips Keep the air filter cl...

Page 3: ...permits fan operation without cooling or heating COOL permits cooling with low fan speed or high fan speed operation depending on which fan speed setting you select HEAT permits heating with low fan speed or high fan speed operation depending on which fan speed setting you select Fan Speed Switch LOW permits low fan s eed for fan L only operation cooling or heating depending on which Selector Swit...

Page 4: ...t VENTILATION OPEN CLOSE Ventilation Control This knob is set at CLOSE at the factory When it is in this position the vent door is closed and only indoor air is filtered cooled or heated and circulated by the air conditioner Switching the knob to OPEN opens the vent door to allow some outside air to enter the room However cooling or heating effectiveness is reduced when the control is set at OPEN ...

Page 5: ...shed at least every 30 days or as often as it needs cleaning Access to the filter is obtained by removing the room cabinet See page 4 To remove the air filter grasp the pull tabs on the front of the filter as shown and pull toward you until the three tabs at the top and bottom of the filter come out of the slots in the chassis Vacuum the filter on the dirty side or wash it with running water Run w...

Page 6: ...pen furnace floor registers and cold air returns Ventilation Control may be set at OPEN position allowing outside air to enter the room Position of the louvers will affect temperature See page 3 BURNING ODOR c Dust accumulating on surface of heating element during transportation or storage AT START OF can cause burning odor at beginning of heating operation This odor should HEATING quicHy dissipat...

Page 7: ...urther help FIRST contact the people who serviced your appliance Explain why you are not pleased In most cases this will solve the problem NEXT if you are still not pleased write all the details including your phone number to Manager Consumer Relations GE Appliances Appliance Park Louisville Kentucky 40225 FINALLY if your problem is still not resolved write Major Appliance Consumer Action Panel 20...

Page 8: ... WHAT IS NOT COVERED Service trips to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Center 800 626 2000 consumer information service Improper installation Failure of the product resulting from if you have an install...