background image

Installation Preparation

Cabinet Preparation & Wire Routing

 The wiring may enter the opening from either side, rear 

or the floor within the shaded area illustrated above 
in figure and defined in

 PREPARE DISHWASHER 

ENCLOSURE

 section.

• Cut a 1-1/2" maximum diameter hole to admit the 

electrical cable. Edges of hole should be smooth and 
rounded. Permanent wiring connections may pass 
through the same hole as the drain hose and hot water 
line, if convenient. If cabinet wall is metal, the hole 
edge must be covered with a bushing.

NOTE:

 

Power cords with plug must pass through a

separate hole in the cabinet.

Electrical Connection to Dishwasher

Electrical connection is on the right front of dishwasher.
• For permanent connections the cable must be routed 

as shown in figure. Cable must extend a minimum of 
24" from the rear wall.

• For power cord connections, install a 3-prong 

grounding type receptacle in the sink cabinet rear wall, 
6" min. or 18" maximum from the opening, 6" to 18" 
above the floor. 

• 

Use only 

WXO9X70910

 (5’ 5” long) or 

WX09X70911

 

(7’ 11” long) Dishwasher Power Cord Kit. Do not use 
an extension cord or adapter plug with this appliance.

PREPARE ELECTRICAL WIRING

5

White

18"

6"

24"

from Wall

3"

from

Cabinet

Alternate Receptacle
Location in Adjacent 
Cabinet

Ground

Black

18"

6"

Receptacle

Location

Area

1-1/2" Dia. Hole (Max.)

Retire todos los conductores de 

corriente del electrodoméstico 

de disyuntor o de la caja del fusible antes de comenzar 

con la instalación. Si no cumple con esto, se podrá 

producir el riesgo de descargas eléctricas.

ADVERTENCIA

Remove all power leading to the 

appliance from the circuit breaker or 

fuse box before beginning installation. Failure to do so 

can result in a risk of electrical shock.

WARNING

La conexión inadecuada del 

conductor de conexión a 

tierra del equipamiento puede provocar un riesgo de 

descarga eléctrica. Consulte a un electricista calificado 

o representante de servicio técnico si tiene dudas sobre 

la correcta conexión a tierra del aparato. No modifique el 

enchufe que se suministra con el aparato; si no calza en el 

tomacorrientes, haga que un técnico calificado le instale 

un tomacorrientes adecuado.

ADVERTENCIA

The improper connection of the 

equipment grounding conductor can 

result in a risk of electric shock. Check with a qualified 

electrician or service representative if you are in doubt that 

the appliance is properly grounded. Do not modify the plug 

provided with the appliance; if it will not fit the outlet, have 

a proper outlet installed by a qualified technician.

WARNING

Metal Cabinet 

Wall

Cord Protector 

(Obtain locally 

as needed)

Hole Diameter 
1-1/2” Maximum

ELECTRICAL REQUIREMENTS

Be sure that the electrical connection and wire size are adequate 

and in conformance with the National Electric Code, ANSI/

NFPA 70 – latest edition, and all local codes and ordinances.

This appliance must have:

• 120V, 60Hz, AC-only, 15-ampere or 20-ampere, fused 

electrical supply.

• Wiring must be 2 wire with ground and rated for 75°C (167°F).
• If the electrical supply does not meet the above 

 requirements, call a licensed electrician before  proceeding.

It is recommended to have:

• A circuit breaker or time-delay fuse.
• A properly grounded individual branch circuit.

Grounding Instructions–Permanent Connection

This appliance must be connected to a grounded metal, 

permanent wiring system, or an equipment-grounding 

conductor must be run with the circuit conductors and be 

connected to the equipment-grounding terminal or lead on 

the appliance.

Grounding Instructions–Power Cord Models

This appliance must be grounded. In the event of a 

malfunction or breakdown, grounding will reduce the risk 

of electric shock by providing a path of least resistance 

for electric current. This appliance is equipped with a cord 

having an equipment-grounding conductor and a grounding 

plug. The plug must be plugged into an appropriate outlet 

that is installed and grounded in accordance with all local 

codes and ordinances.

Summary of Contents for HDA2100HCC

Page 1: ...ment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative if you are in doubt that the appliance is properly grounded If house wiring...

Page 2: ...rrule and compression nut Strain relief for electrical connection Hand shut off valve recommended Air gap for drain hose if required Waste tee for house plumbing if applicable GPF10S drain hose 10 lon...

Page 3: ...cabinet opening must be at least 24 deep 24 wide and approximately 34 1 4 1 4 height This dishwasher fits under a special sink with a depth of 6 or less in a 1 1 2 countertop The dishwasher must be i...

Page 4: ...that drain plug has been removed DISHWASHER WILL NOT DRAIN IF PLUG IS LEFT IN PLACE Method 1 Air Gap with Waste Tee or Disposer An air gap must be used when required by local codes and ordinances The...

Page 5: ...a calificado o representante de servicio t cnico si tiene dudas sobre la correcta conexi n a tierra del aparato No modifique el enchufe que se suministra con el aparato si no calza en el tomacorriente...

Page 6: ...as the electrical cable and drain hose Or cut an additional 1 1 2 diameter hole to accommodate the water line If power cord with plug is used water line must not pass through power cord hole IMPORTANT...

Page 7: ...ension setting to correct balance Tip Avoid service calls for door balance problems Make sure the spring end is fully engaged in a frame hole and the spring link is fully seated in the hinge arm 7 STE...

Page 8: ...stem or has a factory installed power cord In this step you will need the junction box cover and the 10 x 1 2 hex head screw from the screw kit set aside in Step 1 The power cord and connections must...

Page 9: ...y drilled in the cabinet wall If a power cord is used guide the end of the cord through a separate hole cut for the power cord The power cord should be routed directly to the rear of the junction box...

Page 10: ...hands or knees when sliding dishwasher into position STEP 11 LEVEL DISHWASHER IMPORTANT Dishwasher must be level for proper dish rack operation wash performance and door operation The dishwasher must...

Page 11: ...the dishwasher is centered in the cabinet and the door opens and closes freely without hitting the adjacent cabinets Drive mounting screws straight and flush 11 STEP 13 Countertop Bracket Side Mount B...

Page 12: ...ed by the dishwasher CONNECT DRAIN LINE The molded end of the drain hose will fit 5 8 through 1 diameter inlet ports on the air gap waste tee or disposer Determine size of inlet port Cut drain hose co...

Page 13: ...Existe la posibilidad de que el CSM se caiga durante el env o Si esto ocurre el instalador puede reiniciar el CSM durante la instalaci n Si el CSM se cae luego de que el electrodom stico fue instalado...

Page 14: ...ents Check that the door spring does not contact the water line fill hose or adjacent cabinets See Steps 13 and 14 Pull lower rack about halfway out Check to be sure it does not roll back into dishwas...

Page 15: ...sure there are no leaks At the end of the second drain push the RESET pad on electronic models For dial models unlatch the door and rotate the dial to the Off position STEP 19 Red Connector REPLACE A...

Page 16: ...aside in Step 1 Make sure the power cord for the dishwasher is unplugged from the wall outlet Remove screw from junction box cover and remove cover if present Disconnect the three power cord conducto...

Page 17: ...le est d querre et de niveau par rapport au bas et au haut de l ouverture de l armoire sans torsion ni d formation de la cuve ou de la porte Les quatre 4 pieds reposent fermement sur le plancher Le bo...

Page 18: ...t recommand Coupure anti refoulement pour le boyau de vidange si n cessaire Raccord en T pour la plomberie de la r sidence s il y a lieu Boyau de vidange GPF10S 3 m 10 pi de long si n cessaire Collie...

Page 19: ...fond doit tre exempt de tuyaux ou de fils Installer les tuyaux d alimentation d eau et de vidange de l vier dans la section A Installer le tuyau d eau chaude vers le lave vaisselle dans la section B I...

Page 20: ...de vidange LE LAVE VAISSELLE NE POURRA PAS SE VIDER SI VOUS LAISSEZ LE BOUCHON EN PLACE Conseil Pour viter des frais de r paration inutiles Assurez vous d enlever le bouchon de vidange du broyeur d ch...

Page 21: ...la brancher dans la prise de courant faites installer une prise de courant appropri e par un technicien qualifi AVERTISSEMENT Paroi darmoire en m tal Prot ge cordon d alimentation Obtenir localement a...

Page 22: ...boucle de vidange lev e REMARQUE Toutes les conduites se trouvent au dessus en dessous ou c t du lave vaisselle Aucune conduite n a t install e derri re l appareil 6 4 Cabinet Face Shut off Valve 2 F...

Page 23: ...ez les pi ces fournies dans l emballage et mettez les de c t Ensemble de vis Couvercle de la bo te de jonction Boyau de vidange et collier Manuel d utilisation chantillons et ou bons TAPE 1 V RIFICATI...

Page 24: ...oude de 90 pour qu il pointe vers l arri re du lave vaisselle TAPE 6 Support de la bo te de jonction Blanc Noir Couvercle Fils de faisceau de lave vaisselle Cordon d alimentation ou c blage domestique...

Page 25: ...don dans un trou distinct Le cordon d alimentation doit tre achemin directement vers l arri re de la bo te de jonction afin d viter tout contact avec le ressort de la porte et d autres pi ces du lave...

Page 26: ...tact avec des pi ces sous le lave vaisselle Les rebords de la cuve du lave vaisselle doivent tre en retrait d environ 19 mm 3 4 po par rapport au devant des armoires adjacentes Reportez vous la figure...

Page 27: ...ptional 3 4 Support du comptoir 1 9 cm 3 4 po Supports de montage lat raux facultatifs RACCORDEMENT DE L ALIMENTATION EN EAU Raccordez la conduite d alimentation en eau au coude de 90 Si vous d cidez...

Page 28: ...8 mm 5 8 po et 25 4 mm 1 po de la coupure anti refoulement du raccord en T ou du broyeur d chets Mesurez le diam tre de l orifice d entr e Coupez le raccord du boyau de vidange l endroit indiqu au bes...

Page 29: ...rique de la r sidence est en aluminium utilisez un agent antioxydant et des connecteurs pour raccords aluminium cuivre homologu s UL AVERTISSEMENT Le module de d tection de courant est un dispositif d...

Page 30: ...aisselle qu il n est pas coinc ou qu il n entre pas en contact avec les ressorts de la porte ou d autres pi ces de l appareil Assurez vous que les ressorts de la porte n entrent pas en contact avec la...

Page 31: ...initialisation dans le cas des mod les lectroniques Sur les mod les dot s d un s lecteur rotatif d verrouillez la porte et tournez le s lecteur la position Off Arr t 15 TAPE 19 Red Connector Connecte...

Page 32: ...ois conducteurs du cordon d alimentation du faisceau du lave vaisselle Enlevez et jetez le cordon d alimentation Branchez les fils pour la conversion optionnel au faisceau du lave vaisselle en brancha...

Reviews: