HANDHELD DISPLAY – INSTRUCTION MANUAL

1

HandHeld Display

Digital Energy

Multilin

HandHeld Display

1  HandHeld Display

The HHD provides the operator with rapid access to relevant information and controls 
using intuitive sequences. It also provides all available information and setting control with 
an easy-to-use graphic interface.
The HHD includes a rugged enclosure which suits the requirements of on site remote use.  
The unit also includes industrial strength magnets that allow the HHD to be temporarily 
mounted on the LV MCC while accessing the relay. 

1.1  Introduction to the HHD

The central feature of the HHD is a 3.5-inch 320 by 240 pixel backlit color LCD screen. The 
panel also contains keys (pushbuttons) that control the display and perform commands. In 
addition, the interface contains START A, START B, and STOP direct acting control 
pushbuttons.
The display also contains several LED indicators that provide a summary of the machine 
status. Details are displayed on the screen when the user navigates to the appropriate 
page.

Summary of Contents for HandHeld Display (HHD)

Page 1: ...y Multilin GE Multilin 215 Anderson Avenue Markham Ontario Canada L6E 1B3 Tel 905 294 6222 Fax 905 201 2098 Internet http www GEmultilin com Instruction manual HHD revision 1 0x Manual P N 1601 9096 A...

Page 2: ...and FlexLogic are registered trademarks of GE Multilin Inc The contents of this manual are the property of GE Multilin Inc This documentation is furnished on license and may not be reproduced in whole...

Page 3: ...ors 5 2 HHD graphical display pages 6 Home display page 7 Default display 8 Actual values pages 8 Status pages 9 Setpoints pages 11 Diagnostics pages 12 Control page 13 Popup windows 13 3 MM300 MM200...

Page 4: ...toc ii HANDHELD DISPLAY INSTRUCTION MANUAL...

Page 5: ...e The unit also includes industrial strength magnets that allow the HHD to be temporarily mounted on the LV MCC while accessing the relay 1 1 Introduction to the HHD The central feature of the HHD is...

Page 6: ...the time is replaced with the text TEST MODE in red The soft key labels are indicated on the bottom line The soft keys are used for navigation performing functions and for acknowledgement Navigation s...

Page 7: ...to all sub pages and also contains a status and process values summary Double pressing the HOME key recalls the default display Like a screen saver the default display appears after a period of inact...

Page 8: ...de entry For example pressing and holding the ENTER key or attempting a control where a password is required displays the following page Figure 4 Passcode entry dialog box The ESC key functions in dif...

Page 9: ...le parameters The LED colors can be independently configured by the user to display either red orange or green as required by local operating conventions The following LEDs are available for the HHD R...

Page 10: ...e HHD 853701A3 CDR Amps Power Volts Sensor Values Inputs Outputs System Message Flex Summary Status Reset Protection Control Security Config Setpoints CT VT Inputs Outputs Motor Comms System Events Co...

Page 11: ...tripped blocked stopped pre contactor starting running status and inhibit Motor load thermal capacity used and power Estimated time to trip if motor is loaded above its service factor 8883701A1 CDR Am...

Page 12: ...s returns directly to the home page 2 2 Default display The default display is automatically shown when no control key has been pressed for five minutes It can also be recalled at any time by double c...

Page 13: ...the HHD provide the user with up to date information on the current status of the MM300 or MM200 Status pages are divided into five sections for the MM300 and 4 sections for the MM200 Message displays...

Page 14: ...key items such as FLA CT Type starter type and control Source that must be configured before the unit will be available for use Protection values must still be configured for the motor to be protected...

Page 15: ...change is made and it is clear the relay is performing as intended with the new setpoints Figure 13 setpoints home page To streamline the setpoint entry process the HHD will not display setpoints tha...

Page 16: ...for up to 256 events Counters accumulated system counter data Phasors MM300 only metered phasor data Info product information Learned learned values based upon metered data Typical diagnostic pages fo...

Page 17: ...enabled Figure 18 Typical control page display Refer to the Control section for details on control page functionality 2 8 Popup windows There are three types of popup windows Setpoint editor popup win...

Page 18: ...r uninstalled options for example accessing the undervoltage restart page when undervoltage restart option is not ordered Where a keypress is illegal because a security passcode is required the popup...

Page 19: ...ttings select from a limited set of values for example enabled or disabled The following procedure describes how to edit an enumeration setting 1 Use the soft keys to select the relevant setting page...

Page 20: ...t can be disabled In order to activate the functions offered by these buttons the user has to highlight the appropriate button and press Select The UP and DOWN front panel keys can also be used to inc...

Page 21: ...res the selected value while pressing ESC cancels the editing sequence and closes the popup editor The following procedure describes how to edit an alphanumeric setting 1 Use the soft keys to select t...

Page 22: ...lockout reset and firmware download When there are no pop ups present a sustained press on the ESC key clears the security passcode When operations are performed that require a higher level of securit...