background image

Add water and salt to the brine tank:

Remove the cabinet (brine tank) cover. Add about 3 gallons of water into the tank. Do not add

into the brinewell.

Fill tank with 

NUGGET, PELLET

or coarse 

SOLAR

water softener salt with a purity of 99.5% or higher.

Do not use rock, block, granulated, or ice cream-making salts. Salt storage capacity is

approximately 200 lbs. for model GXSS17. Keep the salt hole cover in place on the softener

unless servicing the unit or refilling with salt.

NOTE: 

If the softener is installed in a humid basement or other damp area, it is better to fill the tank

with less salt, more frequently. Eighty to 100 lbs. of salt will last for several months, depending on

water hardness and family size.

Connect to electrical power:

If transformer wiring is not visible at the back of the control head, remove control cover. 

DO NOT

PULL ON OR DISCONNECT WIRING. 

Locate the long wire with U shaped connectors on one end.

Route this wire through the rear of the control housing. Replace the control cover.

Fasten the 2 power cable lugs (U shaped connectors) to the 2 screws on the transformer, and

tighten the screws. Then, plug the transformer into the electrical outlet.

Program the CONTROL.

11

10

9

Customer Ser

vice

Tr

oubleshooting T

ips

Installation Instr

uctions

Safety Instr

uctions

Operating Instr

uctions

9

D.

Place bypass valve in the service position 

EXACTLY

as follows. 

KEEP SOFT WATER FAUCETS OPEN.

SLOWLY 

pull or slide the valve stem toward service, pausing several times to allow the softener to

pressurize slowly. This initial flow of water may be rusty colored. This is normal and will disappear

quickly.

E. 

After about 3 minutes, open a 

HOT

water faucet for 1 minute, or until all air is expelled, then close.

F.

Close all water faucets.

G.

Check your plumbing work for leaks and fix right away if any are found. Be sure to observe

previous caution notes.

H.

Turn on the gas or electric supply to the water heater. Light the pilot, if applicable.

I. 

Sanitize the softener.

Care is taken at the factory to keep your softener clean

and sanitary. Materials used to make the softener will

not infect or contaminate your water supply and will

not cause bacteria to form or grow. However, during

shipping, storage, installing and operating, bacteria

could get into the softener. For is reason, sanitizing 

as follows is suggested when installing.

Lift the salt hole cover and use a pail or hose to

fill the salt storage tank with at least 3 gallons 

of water.

Remove the brinewell cover, see Fig. 7 and pour 

about 3/4 ounce of common 5.25% household 

bleach (Clorox, Linco, BoPeep, White Sail, Eagle,

etc.) in the softener brinewell.

Press the 

TOUCH/HOLD

button and hold for 3

seconds to start a recharge. This first recharge 

does several things: fills the salt tank to the water 

level needed, gets all the air out of the resin tank,

makes the resin bed ready for service. See the

Recharging

section.

NOTE:

This recharge takes about 2 hours.

Fig. 7

Salt hole cover
removed

Hose

Brinewell

Brinewell
cover (remove
and add about
3/4 oz. bleach)

Water, about 
3 gallons

Summary of Contents for GXSS17Z01

Page 1: ...GXSS17Z01 GE Appliances Water Softening System Part No 215C1044P003 1 Pub No 49 50007 1 8 98 CG 7196674 Installation and Owner s Manual GE Answer Center 800 626 2000 ...

Page 2: ... whenever you need quality appliances for your home FOR YOUR RECORDS Write the model and serial numbers here You can find them on the sump bracket Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty Inside you will find many helpful hints on how to use and maintain your water system properly Just a little preventive care on y...

Page 3: ...ng with salt WARNING Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Read and follow this Safety Information carefully SAVE THESE INSTRUCTIONS PROPER INSTALLATION Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather Water freezing in the system will break ...

Page 4: ...all the Softener section for more details WARNING Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system The water should be tested periodically to verify that the system is performing satisfactorily Small parts remaining after the installation could be a choke hazard Discard safely 4 Installation instructions Customer ...

Page 5: ...ener must be at least 3 4 size Some local codes require a minimum of 1 pipe size To plumb with 1 pipes buy adapters to fit the 1 pipe threads on the bypass valve see Fig 1 and Fig 2 Use copper brass or galvanized pipe and fittings Some codes may also allow CPVC plastic pipes Use the included bypass valve to install the softener The bypass valve allows you to turn off water to the softener for serv...

Page 6: ...the 1 threads INLET Brinewell NOTE See Drain Hose Connections section SALT GOES HERE Salt hole cover removed 24V transformer 120 volt outlet Hard water Soft water From softener outlet To softener inlet CROSS OVER Use if water supply flows from the left Include single or 3 valve bypass Hard water Soft water From softener outlet To softener inlet CROSS OVER Use if water supply flows from the left In...

Page 7: ...coming hard water supply is directed to the softener valve inlet port If house water flow is from the left use a plumbing cross over as shown in Fig 1 If making a soldered copper installation do all sweat soldering before connecting pipes to the bypass valve Torch heat will damage plastic parts When turning threaded pipe fittings onto plastic fittings use care not to cross thread Use pipe joint co...

Page 8: ...ain fitting so the cutting blade clears the valve housing to prevent damage to valve Buy a compression fitting 1 4 female pipe thread x 1 2 O D tube and needed tubing from your local hardware store Connect and run the cabinet brine tank overflow hose Attach a length of hose use remaining hose from Step 5 to the drain elbow installed in Step 4 Use a hose clamp to hold it in place Locate the other e...

Page 9: ... or slide the valve stem toward service pausing several times to allow the softener to pressurize slowly This initial flow of water may be rusty colored This is normal and will disappear quickly E After about 3 minutes open a HOT water faucet for 1 minute or until all air is expelled then close F Close all water faucets G Check your plumbing work for leaks and fix right away if any are found Be su...

Page 10: ... steady the minute display day will begin flashing Fig 9 shows the timer set at 3 30 PM B Set the present day of the week Press the SET CLEAR button to set the present day of the week in the display NOTE Press SET CLEAR button and quickly release to move the day display 1 at a time Or hold the SET CLEAR button to move the day display ahead 2 days each second Press the TIME DAY button again to stea...

Page 11: ...ear water iron ppm Water pressure limits min max psi Pressure drop at rated service flow psig Water temperature maximum F Water supply minimum flow rate gpm Regeneration cycle flow rates gpm Fill flow to brine tank Brining Brine Rinse Backwash Fast Rinse GXSS17Z 31 2 6 8 x 40 8 50 3 20 125 15 120 3 3 19 12 1 8 1 8 See rating decal located on the Softener Determined by water analysis from a qualifi...

Page 12: ...heater will fill with the hard water Fill Backwash Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin beads To make the brine water flows into the salt storage area during the fill stage as shown Brining During brining brine travels from the salt storage area into the resin tank Brine is the cleaning agent needed to remove hard minerals from the resin bea...

Page 13: ... but the bridge is under it The following is the best way to check for a salt bridge Salt should be loose all the way to the bottom of the tank Take a broom handle or like tool and carefully push it down into the salt working it up and down If the tool strikes a hard object be sure it s not the bottom or sides of the tank it s most likely a salt bridge Carefully break the bridge with the tool Do n...

Page 14: ...ri Then while holding the nozzle and venturi housing with one hand remove the cap Lift out the screen support and screen then the nozzle and venturi Wash and rinse the parts in warm water until clean If needed use a small brush to remove iron or dirt Also check and clean the gasket NOTE Some models have a small flow plug located in the nozzle and venturi and or a small cone shaped screen in the ho...

Page 15: ...egin to run out of soft water If the softener is not scheduled to regenerate for another day or two you would get hard water until then If this happens or you think it might happen press and hold in the TOUCH HOLD button for three seconds until RCHG shows RCHG will flash in the display during the regeneration which lasts under two hours NOTE Avoid using HOT water while the softener regenerates bec...

Page 16: ...en choosing a regeneration starting time other than 2 00 AM Step 2 Press the SET CLEAR button until the desired regeneration starting time shows in the display NOTE Press SET CLEAR and quickly release to move the display ahead 1 hour at a time Or hold the SET CLEAR button to move display ahead 2 hours each second Step 3 Press the REGENERATION DAY button and SUnday begins to flash If you do want re...

Page 17: ...min M T TH S 3 min M T TH F S SU 3 min Every Day 3 min Every Day 4 min Every Day 4 min M 3 min M TH 3 min M W S 3 min M T TH S 3 min M T TH F S 3 min M T TH F S SU 3 min Every Day 3 min Every Day 4 min Every Day 5 min Every Day 7 min M 4 min M W S 2 min M W S 3 min M T TH F S SU 2 min M T TH F S SU 3 min Every Day 3 min Every Day 4 min Every Day 5 min Every Day 8 min M 5 min M W S 3 min M T TH S 3...

Page 18: ...ion See the About the Face Plate Timer section Manual bypass valve s in Move stem in single bypass valve to SERVICE bypass position Salt in storage tank bridged See the Breaking a Salt Bridge section Dirty plugged or damaged Take apart and clean or replace damaged parts nozzle venturi See Cleaning the Nozzle and Venturi Assembly section Valve drain hose plugged Hose must not have kinks sharp bends...

Page 19: ... protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that al...

Page 20: ...stment Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will need should you require service Our service number is 800 GE CARES 800 452 2737 Read your Owner s Manual carefully It ...

Page 21: ...Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions 21 Parts list ...

Page 22: ...RE 1 0015 WS06X10003 POWER CORD 1 0016 WS26X10001 TRANSFORMER 1 0017 WS31X10010 COVER SALT HOLE 1 0018 WS33X10001 SEAL VAPOR BARRIER 1 0019 WS33X10002 RIM 1 WS31X10003 COVER BRINEWELL 1 0021 WS02X10009 WING NUT 1 4 20 1 0022 WS32X10002 TANK BRINEWELL ROUND 1 0023 WS02X10011 SCREW 1 4 20 NYLON 1 0024 WS32X10003 TANK BRINE ROUND 1 0025 WS18X10003 CLAMPHOSE 1 0026 WS22X10016 ADAPTER HOSE 1 0027 WS22X...

Page 23: ...Parts list Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions 23 ...

Page 24: ... VENT 1 0115 WS03X10015 CONE SCREEN 1 0116 WS22X10021 PLUG FILL FLOW 3 GPM 1 0117 WS03X10017 NUT FERRULE 1 0118 WS15X10009 NOZZLE VENTURI ASM 1 0119 WS03X10018 RETAINER 1 0120 WS03X10019 SEAL O RING 1 4 X 3 8 2 0121 WS15X10010 BODY VALVE 1 0122 WS03X10020 SPRING 1 0123 WS22X10022 PLUG DRAIN SALT 1 0130 WS35X10005 SEAL KIT 1 0132 WS22X10023 ADAPTER DRAIN HOSE 1 0133 WS03X10021 O RING 5 8 X 13 16 1 ...

Page 25: ...Notes Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions 25 ...

Page 26: ...er Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Safety Instructions Customer Service Troubleshooting Tips Safety Instructions ...

Page 27: ...do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company Louisville KY 40225 For The Period Of GE Will Replace...

Page 28: ...irectly to their homes VISA MasterCard and Discover cards are accepted Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualified service personnel Caution must be exercised since improper servicing may cause unsafe operation Service Satisfaction If you are not satisfied with the service you receive from GE First con...

Reviews: