background image

4

SERVICE

When the water softening system is providing 
soft water, it is called “Service.” During service, 
hard water flows from the house main water 
pipe into the water softening system. Inside the 
water softening system resin tank is a bed made 
up of thousands of tiny, plastic resin beads. As 
hard water passes through the bed, each bead 
attracts and holds the hard minerals. This is 
called ion-exchanging. It is much like a magnet 
attracting and holding metals. Water without 
hard minerals (soft water) flows from the water 
softening system and to the house pipes.

After a period of time, the resin beads become 
coated with hard minerals and they have to 
be cleaned. This cleaning is called recharge. 
Recharge is started at 2:00 AM (factory setting) 
by the water softening system control, and 
consists of five stages or cycles. These are 

FILL, BRINING, BRINE RINSE, BACKWASH 
and FAST RINSE.

AUTOMATIC HARD WATER BYPASS DURING RECHARGE

During recharge the water softener is 
automatically put in bypass mode allowing hard 
water to be available to the home. Once the 
softener is recharged water is directed back 
through the softener to be conditioned.

However, you should avoid using HOT water 
because the water heater will fill with the 
hard water.

FILL

Salt dissolved in water is called brine. Brine is 
needed to clean the hard minerals from resin 
beads. To make the brine, water flows into the 
salt storage area during the fill stage.

BRINING

During brining, brine travels from the salt 
storage area into the resin tank. Brine is the 
cleaning agent needed to remove hard minerals 
from the resin beads. The hard minerals and 
brine are discharged to the drain.
The nozzle and venturi create a suction to 
move the brine, maintaining a very slow rate to 
get the best resin cleaning with the least salt.

BRINE RINSE

After a pre-measured amount of brine is used, 
the brine valve closes. Water continues to flow 
in the same path as during brining, except for 
the discontinued brine flow. Hard minerals and 
brine flush from the resin tank to the drain.

BACKWASH

During backwash, water travels up through 
the resin tank at a fast flow rate, flushing 
accumulated iron, dirt and sediments from the 
resin bed and to the drain.

FAST RINSE

Backwash is followed by a fast flow of water 
down through the resin tank. The fast flow 
flushes brine from the bottom of the tank, and 
packs the resin bed.
After fast rinse, the water softening system 
returns to soft water service.

About the water softener system

Summary of Contents for GXSF30V02

Page 1: ...rol panel Model GXSF30V Systems tested and certified by NSF International against NSF ANSI Standard 44 for the chemical reduction claims specified on page 3 and certified to NSF ANSI 372 C USA R Syste...

Page 2: ...fter the system WARNING Discard all unused parts and packaging material after installation Small parts remaining after the installation could be a choke hazard The water softening system works on 24 v...

Page 3: ...efer to Cleaning Iron Out of the Water Softening System section Canada working pressure limits 1 4 7 0 kg cm2 This model is efficiency rated The efficiency rating is valid only at the minimum stated s...

Page 4: ...oned However you should avoid using HOT water because the water heater will fill with the hard water FILL Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin...

Page 5: ...g system is interrupted the control display is blank and the blue indicator light is off but the control keeps correct time for 24 hours When power is restored you have to reset the present time only...

Page 6: ...e It appears as small cloudy yellow orange or reddish suspended particles After the water stands for a period of time the particles settle to the bottom of the container Generally these irons are remo...

Page 7: ...sure all the parts shown below are present Additional parts must be purchased to complete the installation Thoroughly check the water softener for possible shipping damage and parts loss Also inspect...

Page 8: ...n over current device such as a circuit breaker or fuse Always install the water softener between the water inlet and water heater Any other installed water conditioning equipment should be installed...

Page 9: ...the length needed Flexible drain hose is not allowed in all localities check your plumbing codes If local codes do not allow use of a flexible drain hose a rigid valve drain run must be used Purchase...

Page 10: ...e bypass valve Soldering heat will damage the adaptors and valve WARNING A copper or galvanized cold water pipe may be used to ground electrical outlets in the home Failure to maintain this ground pat...

Page 11: ...ot included Pipe 1 1 2 air gap Floor Drain Secure Valve Drain Hose in place over Floor Drain Salt Storage Tank Overflow Hose Overflow Drain Elbow Conditioned Water To Outside Faucets Plug in Power Sup...

Page 12: ...from the top down see Figure 7 and 10 IMPORTANT Be sure the clips snap firmly into place so the single bypass valve will not pull out MOVE WATER SOFTENER INTO PLACE WARNING Excessive Weight Hazard Use...

Page 13: ...er installation do all sweat soldering before connecting pipes to the NPT adapters and bypass valve Torch heat will damage plastic parts WARNING If solder is used to make pipe connection use only lead...

Page 14: ...EST FOR LEAKS To prevent air pressure in the water softener and plumbing system complete the following steps in order 1 Fully open two or more softened cold water faucets close to the water softener l...

Page 15: ...oned To have fully conditioned hot water immediately wait until the initial recharge is over Then drain the water heater following instructions for water heater until water runs cold WARNING Discard a...

Page 16: ...ept changes A beep sounds while pressing buttons for control programming One beep signals a change in the control display Repeated beeps mean the control will not accept a change from the button you h...

Page 17: ...laboratory to request a water hardness test kit at 1 800 949 8220 Option 4 If your report shows hardness in parts per million ppm or milligrams per liter mg l simply divide by 17 1 to get the equivale...

Page 18: ...ay provide erratic operation For example the blue indicator light may flash showing that more salt is required when the actual salt level in the tank is well above the Level 0 In some cases the DAYS T...

Page 19: ...ll provide the most efficient usage of water but may use more salt The degree of difference between these two cycles is highly dependent on the water usage and hardness at a particular installation NO...

Page 20: ...s and Err is in the display electrical problem with system see page 25 LOW SALT SIGNAL When the DAYS TO EMPTY drops to 15 the blue indicator light and DAYS TO EMPTY in the display will flash every sec...

Page 21: ...rrosive fumes that weaken and shorten the life of some water softening system parts CLEANING IRON OUT OF THE WATER SOFTENING SYSTEM Your water softening system takes hardness minerals calcium and magn...

Page 22: ...le and venturi Wash and rinse the parts in warm water until clean If needed use a small brush to remove iron or dirt Also check and clean the gasket NOTE Some models have a small flow plug located in...

Page 23: ...e is under it The following is the best way to check for a salt bridge Salt should be loose all the way to the bottom of the tank Take a broom handle or like tool and carefully push it down into the s...

Page 24: ...r if the tank is empty refill with recommended salt Press for 3 seconds the RECHARGE button to start an immediate recharge and restore soft water supply External power supply unplugged at wall outlet...

Page 25: ...s it the abrasive feel you may have been accustomed to The slippery feel is the clean feel of soft water Water Softener not using any salt Water softening system is a demand unit Does not use much sal...

Page 26: ...Sanitization Procedures At completion of recharge cycle approx 2 hours run water from faucets to purge the salty water Low water pressure Check pressure Drain height 8 or less pressure should be minim...

Page 27: ...ow to further isolate the problem Procedure for removing error code from display 1 Unplug transformer from electrical outlet 2 Correct problem 3 Plug in transformer 4 Wait 8 minutes The error code wil...

Page 28: ...lectrical power applied b Press the DOWN button to display the number of regenerations initiated by the electronic control since the code number was entered 6 Press and hold the MODE SET button until...

Page 29: ...e and cleaning of the water softening system section If the water softening system does not draw brine check nozzle and or venturi dirty or defective defective nozzle and venturi seal nozzle and ventu...

Page 30: ...30 8 7 6 5 11 16 146 5 999 29 4 12 2 13 3 7 8 9 10 56 56 17 19 20 22 23 23 24 30 26 Exploded View...

Page 31: ...31 Cross section View Seal Wear Strip 124 109 110 111 112 113 114 116 115 117 118 120 119 146 106 105 103 130 107 108 130 121 147 152 122 123 130 151 130 132 136 140 138 141 145 Exploded View...

Page 32: ...COVER VALVE 1 0107 WS03X10010 WASHER WAVE 1 0108 WS26X10002 ROTOR DISC ASM 1 0109 WS19X10010 CAP 1 0110 WS03X10011 SEAL O RING 1 125 X 1 37 1 0111 WS19X10005 SUPPORT SCREEN 1 0112 WS03X10013 SCREEN 1...

Page 33: ...n Authorized GE Appliances Service location for service In Alaska the limited warranty excludes the cost of shipping or service calls to your home Some states do not allow the exclusion or limitation...

Page 34: ...y is extended to the original purchaser for products purchased for home use within Canada In home warranty service will be provided in areas where it is available and deemed reasonable by Mabe to prov...

Page 35: ...nimum Buyer Renter ______________________________________________ Date _______________ Seller ____________________________________________________ Date _______________ Seller s Address________________...

Page 36: ...ded warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your warra...

Page 37: ...para los reclamos sobre reducci n de qu micos especificados en la p gina 39 y certificados para NSF ANSI 372 C USA R Sistema probado y certificado por Water Quality Association en cumplimiento con CSA...

Page 38: ...erci rese de usar exclusivamente el transformador incluido El transformador se debe conectar nicamente a un tomacorriente interior con conexi n a tierra de 120 voltios Utilice nicamente sales para des...

Page 39: ...sulte la secci n Limpieza del Hierro con el Sistema Suavizante de Agua L mites de presi n en Canad 1 4 7 0 kg cm2 Este modelo cuenta con una calificaci n de eficiencia El ndice de eficiencia es v lido...

Page 40: ...E debido a que el calentador de agua se llenar con el agua dura LLENADO La sal disuelta en agua es llamada salmuera La salmuera es necesaria para limpiar los minerales duros de las diminutas part cula...

Page 41: ...una recarga de inmediato y al finalizar en unas dos horas contar con un nuevo suministro de agua suave Una vez iniciada ya no podr cancelar esta recarga FUNCI N MEMORIA Si el suministro el ctrico del...

Page 42: ...rt culas turbias suspendidas de color amarillo anaranjado o rojizo Una vez que el agua se asent por un per odo de tiempo las part culas quedan en el fondo del envase Generalmente estos hierros son eli...

Page 43: ...o Dos llaves ajustables 2 accesorios para conectar la tuber a de su residencia a las roscas hembras NPTF de 2 5 cm 1 en el alojamiento del filtro Es posible que se necesite partes adicionales para com...

Page 44: ...disyuntor o fusible Siempre instale el suavizante de agua entre la entrada de agua y el calentador de agua Cualquier otro equipamiento para el acondicionamiento de agua deber a ser instalado entre la...

Page 45: ...o est permitido en todas las localidades consulte sus c digos de plomer a Si los c digos locales no permiten el uso de una manguera de drenaje flexible se deber usar un drenaje con v lvula r gida Adqu...

Page 46: ...dores y la v lvula ADVERTENCIA Una tuber a de cobre o galvanizada de agua fr a podr a usarse para conectar a tierra los tomacorrientes el ctricos en la casa No mantener esta conexi n a tierra podr a r...

Page 47: ...dor de Transpiraci n NPT de 1 no incluido Tuber a 1 1 2 air gap Drenaje por Suelo Secure Valve Drain Hose in place over Floor Drain Manguera de Desborde del Salmuera Tanque Adaptador para Desbordes Ag...

Page 48: ...cia abajo consulte las Figuras 7 y 10 IMPORTANTE Aseg rese de que las abrazaderas queden firmes de modo que la v lvula de desviaci n simple no se suelte MUEVA EL SUAVIZANTE DE AGUA A SU LUGAR ADVERTEN...

Page 49: ...desviaci n El calor de la linterna da a las partes pl sticas ADVERTENCIA Si se har n soldaduras para la conexi n de las tuber as use s lo soldadoras y fundidores libres de plomo para evitar el envenen...

Page 50: ...e agua a la manguera de desborde del tanque de almacenamiento de sal PRUEBA DE P RDIDAS Para evitar la presi n de aire en el suavizante de agua y en el sistema de plomer a complete los siguientes paso...

Page 51: ...on agua caliente acondicionada de forma inmediata espere hasta que la recarga inicial est terminada Luego drene el calentador de agua siguiendo instrucciones para el calentador de agua hasta que el ag...

Page 52: ...tido suena al presionar los botones para la programaci n del control Un pitido se ala un cambio en la pantalla de control Pitidos repetidos indican que el control no aceptar un cambio desde el bot n q...

Page 53: ...un kit de evaluaci n de la dureza del agua al 1 800 949 8220 Opci n 4 Si su informe muestra una dureza en partes por mill n ppm o miligramos por litro mg l simplemente divida esto por 17 1 para obtene...

Page 54: ...emanas de funcionamiento DAYS TO EMPTY D as Hasta Vaciarse podr tener un funcionamiento err tico Por ejemplo la luz Indicadora azul podr titilar mostrando que se necesita m s sal cuando el nivel de sa...

Page 55: ...o es posible que se use m s sal El grado de diferencia entre estos dos ciclos es altamente dependiente del uso y el nivel de dureza del agua en una instalaci n particular NOTA Las Regulaciones de Cali...

Page 56: ...ra La luz titila y Err aparece en la pantalla problema el ctrico con el sistema SE AL DE NIVEL DE SAL BAJO Cuando la funci n DAYS TO EMPTY D as Hasta Vaciarse cae a 15 la luz azul indicadora y DAYS TO...

Page 57: ...bi n puede liberar gases corrosivos que debilitan y acortan la vida til de algunas partes del sistema suavizante de agua LIMPIEZA DEL HIERRO DEL SISTEMA SUAVIZANTE DE AGUA Su sistema suavizante de agu...

Page 58: ...t n limpias De ser necesario use un pincel peque o para retirar el hierro o la suciedad Tambi n controle y limpie la junta NOTA Algunos modelos cuentan con un enchufe de flujo peque o ubicado en la bo...

Page 59: ...st debajo de sta La siguiente es la mejor forma de controlar la formaci n de un puente de sal La sal deber a estar suelta hasta el fondo del tanque Tome un mango de escoba o una herramienta similar y...

Page 60: ...ga para comenzar una recarga de inmediato y restablecer el suministro de agua suave Suministro de corriente externa desenchufado del tomacorriente de pared o el cable de corriente no est conectado al...

Page 61: ...La sensaci n resbalosa es la sensaci n pura del agua suave Consulte la secci n Ajuste de la Dureza del Agua Suavizante de Agua sin uso de sal El sistema suavizante de agua es una unidad de demanda No...

Page 62: ...n Al completar el ciclo de recarga aprox 2 horas deje correr el agua en los grifos para purgar el agua salada Presi n baja del agua Controle la presi n Altura del drenaje de 8 o menos la presi n debe...

Page 63: ...a n m s el problema Procedimiento para eliminar el c digo de error de la pantalla 1 Desenchufe el transformador del tomacorriente el ctrico 2 Corrija el problema 3 Enchufe en el transformador 4 Esper...

Page 64: ...s iniciadas por el control electr nico desde que el c digo num rico fue ingresado 6 Mantenga presionado el bot n MODE SET Modo Configuraci n hasta que el c digo del modo F30 para GXSH30V aparezca en l...

Page 65: ...do y Limpieza del Sistema Suavizante de Agua Si el sistema suavizante de agua no hace que ingrese salmuera controle Suciedad o defectos en la boquilla y o el venturi Defecto en el sellado de la boquil...

Page 66: ...66 Vista Expandida 8 7 6 5 11 16 146 5 999 29 4 12 2 13 3 7 8 9 10 56 56 17 19 20 22 23 23 24 30 26...

Page 67: ...67 Vista Expandida Cross section View Seal Wear Strip 124 109 110 111 112 113 114 116 115 117 118 120 119 146 106 105 103 130 107 108 130 121 147 152 122 123 130 151 130 132 136 140 138 141 145...

Page 68: ...WS03X10010 ARANDELA ONDULADA 1 0108 WS26X10002 ENSAMBLE DE ROTOR Y DISCO 1 0109 WS19X10010 TAPA 1 0110 WS03X10011 SELLO ANILLO O 1 125 X 1 37 1 0111 WS19X10005 PANTALLA DE SOPORTE 1 0112 WS03X10013 PA...

Page 69: ...ue traiga el producto a una Ubicaci n del Servicio T cnico de GE Appliances Autorizado para recibir el servicio En Alaska la garant a excluye el costo de env o o llamadas del servicio a su hogar Algun...

Page 70: ...electr nico si fallara debido a un defecto en los materiales o la fabricaci n Durante esta garant a limitada de tres a os usted ser responsable por cualquier trabajo o costos relacionados con el servi...

Page 71: ...un m nimo de 2 a os Comprador Arrendatario_____________________________________ Fecha ______________ Vendedor _________________________________________________ Fecha ______________ Domicilio del Vend...

Page 72: ...uentos especiales que est n disponibles mientras su garant a a n est vigente La puede adquirir en cualquier momento a trav s de Internet Los servicios de GE Appliances a n estar n all cuando su garant...

Reviews: