Installation Instructions

GAS REQUIREMENTS

DRYER GAS SUPPLY CONNECTION

GAS SUPPLY

•  A 1/8” National Pipe Taper thread plugged 

tapping, accessible for test gauge connection, 
must be installed immediately upstream of the 
gas supply connection to the dryer. Contact your 
local gas utility should you have questions on the 
installation of the plugged tapping.

•  Supply line is to be 1/2” rigid pipe and equipped 

with an accessible shutoff within 6 feet of, and in 
the same room with, the dryer.

•  Use pipe thread compound appropriate for 

natural or LP gas or use PTFE tape.

•  Connect flexible metal connector to dryer and 

gas supply.

ADJUSTING FOR ELEVATION

•  Gas  clothes  dryers  input  ratings  are  based  on 

sea  level  operation  and  need  not  be  adjusted 
for  operation  at  or  below  2000  ft.  elevation.  For 
operation  at  elevations  above  2000  ft.,  input 
ratings  should  be  reduced  at  a  rate  of  4  percent 
for each 1000 ft. above sea level. 

•  Installation  must  conform  to  local  codes  and 

ordinances  or,  in  their  absence,  the  NATIONAL 
FUEL GAS CODE, ANSI Z223.

You must use with this dryer a flexible metal connector 
(listed connector ANSI Z21.24 / CSA 6.10). The length 
of the connect shall not exceed 3 ft.

•   Use a new CSA International approved flexible 

gas supply line. Never reuse old flexible 
connectors.

•   Install an individual manual shut-off valve 

within 6ft. of the dryer in accordance with the 
National Fuel Gas Code, ANSI Z223.1/NFPA 
54.

•   Securely tighten all gas connections.
•   If connected to LP gas, have a qualified 

person make sure gas pressure 

DOES NOT

 

exceed 13” water column.

•   Examples of a qualified person include: 

licensed heating personnel, authorized gas 
company personnel, and authorized service 
personnel.

•   Failure to do so can result in death, 

explosion, or fire.

•  The installation must conform with local 

codes, or in the absence of local codes, with 
the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the Natural Gas and Propane 
Installation Code, CSA B149.1.

FOR USE WITH NATURAL GAS ONLY

Dryer as produced by manufacturer is to be used 
only with a natural gas supply. A manufacturer-
supplied conversion kit is required to convert 
this dryer for propane gas supply. Use propane 
gas conversion kit WE25M73 for 24” models or 
WE25M74 for 27” models. Conversion must be 
made by properly trained and qualified personnel 
in accordance with local codes and ordinances.

27” GAS SUPPLY CONNECTION

NOTE: 24” Gas supply connection

 has a flexible 

hose thus dimensions will vary.

3”

3”

Rear View of Appliance

Fire Hazard

- Fire Hazard

WARNING

-  Explosion Hazard

WARNING

Summary of Contents for GUD24GSSM0WW

Page 1: ...s product contains one or more chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Gas appliances can cause low level exposure to some of these substances including benzene carbon monoxide formaldehyde and soot caused primarily by the incomplete combustion of natural gas or LP fuels Exposure to these substances can be minimized by properly ventin...

Page 2: ...bs FOR GAS DRYERS ONLY Gas Inlet Rear View of Appliance 2 24 NOMINAL PRODUCT DIMENSIONS 24 5 8 43 33 7 8 27 3 8 32 3 4 51 18 Water Inlets rear Drain outlet rear Vent 23 3 4 37 1 4 4 1 4 21 1 8 74 7 8 51 3 8 8 5 8 3 NOTE With feet set at mid position feet can be adjusted 3 8 Dimension represents door closed including handle and knobs FOR GAS DRYERS ONLY Gas Inlet Rear View of Appliance 3 27 NOMINAL...

Page 3: ...re inches of open area for GUD24 series models 120 square inches of open area for GUD27 and GUV27 series models NOTE WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER THE CONFIGURATION OF THE DUCTING MAY REQUIRE GREATER THAN 3 OF REAR CLEARANCE Gas Dryers Only No other fuel burning appliance shall be installed in the same closet as a gas dryer The dryer must be disconnected from the gas su...

Page 4: ...s connector and ducting material Shut off Valve MATERIALS YOU WILL NEED Ŷ 4 dia metal elbow Ŷ Pipe compound or PTFE tape Ŷ Flexible gas line connector Ŷ Duct clamps 2 or Spring clamps 2 Ŷ Safety glasses Ŷ 4 dia metal duct recommended Ŷ Gloves Ŷ Soap solution for leak detection Ŷ Exhaust hood Ŷ Duct tape Ŷ Gas pipe adapters 2 for 27 dryers only elbow for 27 dryers only and pipe plug TOOLS YOU WILL ...

Page 5: ...t exceed 3 ft Use a new CSA International approved flexible gas supply line Never reuse old flexible connectors Install an individual manual shut off valve within 6ft of the dryer in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Securely tighten all gas connections If connected to LP gas have a qualified person make sure gas pressure DOES NOT exceed 13 water column Examples of a q...

Page 6: ...ptor 27 ONLY New metal flexible gas line connector Adaptor 1 8 NPT pipe plug for checking gas inlet pressure 6KXW 2ႇ YDOYH Pipe size at least 1 2 Floor 24 27 Tighten the flexible gas line to the adaptor using 2 adjustable wrenches 27 Apply pipe compound to the adaptor and appliance gas inlet 27 Apply pipe compound to all male threads Tighten the flexible gas line to the appliance inlet using 2 adj...

Page 7: ...ded 3 prong grounding type receptacle GROUNDING INSTRUCTIONS This appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This appliance uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is proper...

Page 8: ...liers Ŷ Flat blade screwdriver Ŷ 1 4 Nutdriver Ŷ Level Ŷ 4 dia UL listed flexible metal duct if needed Ŷ Appliance power cord kit not provided with appliance UL rated 120 240V 30A with 3 or 4 prongs Identify the plug type as per the house receptacle before purchasing line cord ELECTRICAL CONNECTION LOCATION POWER CORDS GE Appliances strongly recommends the use of factory specified parts Select the...

Page 9: ...connected dryer This appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This appliance uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with ...

Page 10: ... securely 8 Properly secure power cord to strain relief 9 Reinstall the cover NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK L1 N L2 RELOCATE GREEN GROUND SCREW HERE STRAIN RELIEF BRACKET GREEN OR YELLOW WIRE 3 4 UL RECOGNIZED STRAIN RELIEF HOT WIRE SCREWS 3 HOT WIRE COVER NEUTRAL White REMOVE GROUND STRAP AND DISCARD KEEP GREEN GROUND SCREW 4 10 AW...

Page 11: ...r cord to strain relief 9 Reinstall the cover NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK 1 Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located on the back 4 Install 3 4 in UL recognized strain relief to ...

Page 12: ...nada and the United States only transition ducts that comply with UL 2158A STANDARD FOR CLOTHES DRYER TRANSITION DUCT shall be used Avoid resting the duct on sharp objects For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap t...

Page 13: ... of the system including the transition duct EXHAUST LENGTH DO NOT bend or collapse ducting Use elbows if turns are necessary DO NOT use excessive exhaust length Cut duct as short as possible DO NOT crush duct against the wall DO NOT set appliance on duct DO cut duct as short as possible and install straight into wall DO use elbows when turns are necessary EXHAUST LENGTH 27 NORMAL VENT MODELS RECO...

Page 14: ...ould require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and dampened exhaust hood wall cap SEALING OF JOINTS All joints should be tight to avoid leaks Th...

Page 15: ...desired Rotate elbow sections so that the opening points to the side to which you want to vent Preassemble 4 elbow with 4 duct Use only 4 UL approved rigid metal for ducting inside the dryer Insert duct assembly through the side opening and connect to the internal dryer elbow duct Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct Apply duct tape as shown o...

Page 16: ...UCETS Must be within 42 of the appliance water inlet hose connections The faucets must be 3 4 garden hose type so inlet hoses can be connected WATER PRESSURE Must be between 20 and 120 pounds per square inch with a maximum unbalance pressure hot vs cold flowing of 10 pounds per square inch WATER TEMPERATURE Water heater should be set to deliver 120 F 50 C to 150 F 66 C in the washer when HOT wash ...

Page 17: ...pliance in its final position place a level on top of back part of the washer lid and check it side to side then check front to back Screw the front leveling legs up or down to ensure the appliance is resting solid on all four legs no rocking or the appliance should exist turn the lock nuts on each leg up toward the base of the unit and snug with a wrench NOTE Keep the leg extension at minimum to ...

Page 18: ...18 Notes ...

Page 19: ...19 Notes ...

Page 20: ...20 Printed in Mexico ...

Reviews: