GE GTX65GBSJ Dimensions And Installation Information Download Page 3

GTX65GBSJ 

GE Appliances 6.1 Cu. Ft. Capacity Aluminized Alloy Drum Gas Dryer with HE Sensor Dry

For answers to your Monogram, GE Café

 Series, GE Profile

 Series or 

GE Appliances product questions, visit our website at geappliances.com 
or call GE Answer Center

®

 Service, 800.626.2000.

Specification Revised 5/16

FOR COMPLETE INFORMATION, SEE INSTALLATION INSTRUCTIONS PACKED WITH 

YOUR DRYER.
DUCTING MATERIALS:

 

For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If 
rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit 

WX08X10077). In special installations, it may be necessary to connect the dryer to the house vent 

using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY 

in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where 
a 4" diameter can be maintained throughout the entire length of the transition duct. Please see 

installation instruction packed with your dryer for complete instructions when using flexible metal 
(foil type) ducting.

EXHAUST LENGTH CALCULATION:

 

1.  Determine the number of 90° turns needed for your installation. If you exhaust to the side or 

bottom of dryer, add one turn.

2.  The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown 

in the table. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be 
treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.

Dryers must be exhausted to the outside.

CAUTION:

 For personal safety do not terminate exhaust into a chimney, under any enclosed house 

floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture 
could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen 
exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, 
etc. The wall cap must also be located at least 12" above the ground or any other obstruction with 
the opening pointed down.

FOR MORE INFORMATION ON VENTING KITS AND ACCESSORIES,  

PLEASE CALL 1-800-GE-CARES.

DRYER EXHAUSTING INFORMATION—

USE METAL DUCT ONLY VERTICAL AND 

HORIZONTAL DUCTING

A

B

2-1/2

4

GE Dryer Vent

A

B

2-1/2

4

GE Dryer Vent

A

BEST PERFORMANCE

Maximum length  
of 4" dia rigid  
metal duct
Exhaust hood type

Domestic dryer models 

Number 

of 90° 

turns

A

4"  

opening

B

2-1/2" 

opening

Long Vent 6.1-7.4 cu. ft.  
capacity electric & gas 
(GTD33, GTD42, GTD45, 
GTD65, GTX22, GTX33, GTX42 
and GTX65)

0

120 ft.

90 ft.

1

100 ft.

75 ft.

2

85 ft.

65 ft.

3

70 ft.

55 ft.

4

60 ft.

45 ft.

5

55 ft.

35 ft.

For every extra 90° elbow, reduce the allowable vent system 

length by 10 ft.

Two 45° elbows will be treated like one 90° elbow. 

For the side exhaust installations, add one 90° elbow to the chart. 

When calculating the total vent system length, you must add all 

the straight portions and elbows of the system (including the 

transition duct.

Summary of Contents for GTX65GBSJ

Page 1: ...n INSTALLATION INFORMATION For complete information see installation instructions packed with your dryer DIMENSIONS AND INSTALLATION INFORMATION IN INCHES SPECIAL INSTALLATION REQUIREMENTS ALCOVE OR CLOSET INSTALLATION If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST be exhausted to the outside Minimum clearances betwee...

Page 2: ...te at geappliances com or call GE Answer Center Service 800 626 2000 Specification Revised 5 16 22 1 2 27 3 4 26 4 1 3 4 3 1 4 4 1 4 37 1 2 44 27 5 Power Cord 4 1 2 11 3 4 Side View Rear View 5 7 cu ft Dryers 2 Back View Power Cord Hole 30 1 2 5 8 6 0 and 7 0 cu ft Dryers 5 Back View Power Cord Hole 4 1 2 POWER CORD LOCATIONS BACK VIEW SIDE VIEW REAR VIEW DIMENSIONS AND INSTALLATION INFORMATION IN...

Page 3: ...urns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Dryers must be exhausted to the outside CAUTION For personal safety do not terminate exhaust into a chimney under any enclosed house floor crawl space or into an attic since the accumulated lint could create a fire hazard or moisture could cause damage Never terminate the exhaust into a commo...

Page 4: ... Extended Tumble Tumble clothes without heat to help prevent creasing and wrinkling HE Sensor Dry Keep your clothes looking and feeling their best Dual thermistors continually monitor temperature with a sensor bar that measures moisture to prevent over drying My Cycle Settings Dry clothes with the settings you prefer on any cycle rather than the defaults and store your settings for later use Damp ...

Reviews: