background image

Specification Created 7/15

For answers to your Monogram,

® 

GE Profile

 

or GE

®

 appliance questions, visit our website 

at geappliances.com or call GE Answer Center

®

 

service, 800.626.2000.

Gtx60GBsJ 

GE

®

 Series 6.2 cu. ft. capacity Aluminized alloy drum  

gas dryer with HE Sensor Dry

DryEr ExhaustinG infOrmatiOn—

usE mEtal Duct Only vErtical anD 

hOrizOntal DuctinG

A

B

2-1/2

4

GE Dryer Vent

A

B

2-1/2

4

GE Dryer Vent

A

BEst pErfOrmancE

Maximum length  
of 4" dia rigid  
metal duct
Exhaust hood type

Domestic dryer models 

Number 

of 90° 

turns

A

4"  

opening

B

2-1/2" 

opening

GE Frontload Long Vent 7.0 
cu. ft. capacity electric dryer 
(GFDL)

0

200 ft.

175 ft.

1

185 ft.

165 ft.

2

175 ft.

155 ft.

3

165 ft.

145 ft.

4

155 ft.

135 ft.

5

145 ft.

125 ft.

Long Vent 6.0 - 8.0 cu. ft.  
capacity electric & gas dryers 
(GTDL and GTV)

0

150 ft.

125 ft.

1

135 ft.

115 ft.

2

125 ft.

105 ft.

3

115 ft.

95 ft.

4

105 ft.

85 ft.

5

95 ft.

75 ft.

Long Vent 7.0 cu. ft. capacity 
electric & gas (GTD42, GTD45, 
GTD65, GTX42 and GTX60)

0

120 ft.

90 ft.

1

100 ft.

75 ft.

2

85 ft.

65 ft.

3

70 ft.

55 ft.

4

60 ft.

45 ft.

5

55 ft.

35 ft.

All 6.0 - 8.3 cu. ft. capacity 
models electric and gas dryers 
(GFDS, GFDR, GFDN, GTDS, 
GTDN, GHDN, GHDS, GTDP, 
GLDP, GTD, HTDP, HTDX)

0

90 ft.

60 ft.

1

60 ft.

45 ft.

2

45 ft.

35 ft.

3

35 ft.

25 ft.

4

25 ft.

15 ft.

DCVH480

0

90 ft.

60 ft.

1

60 ft.

45 ft.

2

45 ft.

35 ft.

3

35 ft.

25 ft.

All 3.6 cu. ft. (DSKS, DSKP)
electric dryers

0

46 ft.

37 ft.

1

37 ft.

30 ft.

2

30 ft.

22 ft.

3

23 ft.

15 ft.

Laundry Center GUD27

0

56 ft.

42 ft.

1

48 ft.

34 ft.

2

40 ft.

26 ft.

3

32 ft.

18 ft.

Laundry Center GUD24

0

43 ft.

36 ft.

1

33 ft.

26 ft.

2

24 ft.

16 ft.

fOr cOmplEtE infOrmatiOn, sEE installatiOn instructiOns 

packED with yOur DryEr.
DuctinG matErials:

 

For best performance, this dryer should be vented with 4" diameter all rigid metal 
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-
rigid) ducting can be used (Kit WX08X10077). In special installations, it may be 
necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. 
A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where 
rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” 
diameter can be maintained throughout the entire length of the transition duct. Please 
see installation instruction packed with your dryer for complete instructions when using 
flexible metal (foil type) ducting.

Exhaust lEnGth calculatiOn:

 

1.   Determine the number of 90° turns needed for your installation. If you exhaust to 

the side or bottom of dryer, add one turn.

2.   The maximum length of 4" rigid (aluminum or galvanized) duct which can be 

tolerated is shown in the table. A turn of 45° or less may be ignored. Two 45° turns 
within the duct length should be treated as a 90° elbow. A turn over 45° should be 
treated as a 90° elbow.

Dryers must be exhausted to the outside.

cautiOn:

 For personal safety do not terminate exhaust into a chimney, under any 

enclosed house floor (crawl space), or into an attic, since the accumulated lint could 
create a fire hazard or moisture could cause damage. Never terminate the exhaust into 
a common duct or plenum with a kitchen exhaust, since the combination of lint and 
grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, 
bird nesting, etc. The wall cap must also be located at least 12" above the ground or any 
other obstruction with the opening pointed down.

fOr mOrE infOrmatiOn On vEntinG kits anD accEssOriEs, plEasE 

call 1-800-GE-carEs.

Summary of Contents for GTX60GBSJ

Page 1: ...ee installation instructions packed with your dryer Dimensions and Installation Information in inches Special Installation Requirements Alcove or Closet Installation If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST be exhausted to the outside Minimum clearances between dryer cabinet and adjacent walls or other surfaces ...

Page 2: ...2000 GTX60GBSJ GE Series 6 2 cu ft capacity Aluminized alloy drum gas dryer with HE Sensor Dry 22 1 2 26 3 4 4 1 3 4 3 1 4 4 1 4 37 1 2 44 27 5 Power Cord 4 1 2 11 3 4 Side View Rear View 5 7 cu ft Dryers 2 Back View Power Cord Hole 30 1 2 5 8 6 0 and 7 0 cu ft Dryers 5 Back View Power Cord Hole 4 1 2 Power Cord Locations Dimensions and Installation Information in inches ...

Page 3: ...or best performance this dryer should be vented with 4 diameter all rigid metal exhaust duct If rigid metal duct cannot be used then UL listed flexible metal semi rigid ducting can be used Kit WX08X10077 In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct A UL listed flexible metal foil type duct may be used ONLY in installation...

Page 4: ...ft venting capability Provides flexible installation Extended Tumble Freshly tumbles your garments periodically for up to 8 hours when unable to move clothing to the dryer right away HE Sensor Dry Keep your clothes looking and feeling their best Dual thermistors continually monitor temperature with a sensor bar that measures moisture to prevent over drying My Cycle Settings Dry clothes with the se...

Reviews: