background image

18

Installation Instructions

REVERSING THE DOOR (cont.)

A  

 

REVERSING THE DOOR - SOLID DOOR 

MODELS (cont.)

5

 Mount the door on the 2 upper left side hinge 

screws installed in step 2. Move the hinge screws 

loosened in step 3 into the lower left side screw 

holes and firmly tighten all 4 screws.

6

 Install the 4 plastic caps removed in step 1 into the 

4 right side front panel holes. 

NOTE:

 To return the door to the original setup, follow 

these instructions, swapping “left” and “right”.

When you finish

Plug the dryer back into  

its electrical outlet.

Door

Hang door and 

tighten screws

Plastic Cap (4)

Right side of 

front panel

Summary of Contents for GTD84GCPNDG

Page 1: ...st not exceed 4 feet FOR GAS DRYERS ONLY BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local electrical inspector s use IMPORTANT Observe all governing codes and ordinances Install the clothes dryer according to the manufacturer s instructions and local codes Note to Installer Be sure to leave these instructions with the Consumer Note to Co...

Page 2: ... Order on line at GEApplianceparts com 24 hours a day or by phone at 877 959 8688 during normal business hours STEAM WATER HOSES for steam dryer models only ACCESSORIES Order on line at GEApplianceparts com 24 hours a day or by phone at 877 959 8688 during normal business hours Part Number Accessory PM14X10056 Dryer door opening vent brush WX14X10007 LintEater Dryer rotary tube brush PM08X10085 Fl...

Page 3: ...the floor for a garage installation Failure to do so can result in death explosion or fire The dryer MUST be vented to the outdoors Minimum clearance between dryer cabinet and adjacent walls or other surfaces is 0 either side 1 rear 1 front 1 top Consideration must be given to provide adequate clearance for installation and service Closet doors must be louvered or otherwise ventilated and have at ...

Page 4: ...on at the same time NOTE Use new inlet hoses never use old hoses 1 Turn the cold water faucet off Remove the washer inlet hose from the washer fill valve connector cold 2 Ensure the rubber flat washer is in place and attach one female coupling of the short hose provided onto the washer fill valve connector Tighten by hand until firmly seated 3 Attach one male end of the Y connector to the other fe...

Page 5: ...d discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 4 dia metal elbow Pipe compound or PTFE tape Flexible gas line connector Duct clamps 2 or Spring clamps 2 Safety glasses 4 dia metal duct recommended Gloves Soap solution for leak detection Exhaust hood Duct tape Gas pipe adapters 2 elbow and pipe plug TOOLS YOU WILL NEED 10 Adjustable wrenches 2 8 Pip...

Page 6: ...l not exceed 4 feet Use a new CSA International approved flexible gas supply line Never reuse old flexible connectors Install an individual manual shut off valve within 6ft of the dryer in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Securely tighten all gas connections If connected to LP gas have a qualified person make sure gas pressure DOES NOT exceed 13 water column Examples ...

Page 7: ...YER TO THE GAS SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8 NPT elbow at the end of the dryer gas inlet Install a 3 8 flare union adapter to the female elbow IMPORTANT Use a pipe wrench to securely hold on to the end of the dryer gas inlet to prevent twisting...

Page 8: ...kdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances Improper connection of the equipment grounding conductor c...

Page 9: ...WILL NEED Slip joint pliers Level 4 dia UL listed flexible metal duct if needed Dryer power cord kit not provided with dryer UL rated 120 240V 30A with 3 or 4 prongs Identify the plug type as per the house receptacle before purchasing line cord Flat blade screwdriver Phillips screwdriver 4 Cover Plate Kit WE49X22606 if needed POWER CORDS GE Appliances strongly recommends the use of factory specifi...

Page 10: ...This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordi...

Page 11: ...LEAVE THE COVER OFF OF THE TERMINAL BLOCK NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK 1 Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located at the lower back 4 Install 3 4 in UL recognized strain relief to power cord entry hole Bring power cord through...

Page 12: ...nada and the United States only transition ducts that comply with UL 2158A STANDARD FOR CLOTHES DRYER TRANSITION DUCT shall be used Avoid resting the duct on sharp objects For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap t...

Page 13: ... 45 elbows will be treated like one 90 elbow For the side exhaust installations add one 90 elbow to the chart For every additional 90 elbow reduce the allowable vent system length by 10 feet When calculating the total vent system length you must add all the straight portions and elbows of the system including the transition duct EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommen...

Page 14: ...irflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and dampened exhaust hood wall cap SEALING OF JOINTS All joints should be tight to a...

Page 15: ...he screw saved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO RIGHT ELECTRIC MODELS ONLY OR LEFT SIDE OF CABINET Preassemble 4 elbow with 4 duct Wrap duct tape around joint Insert duct assembly elbow first through the side opening and connect the elbow to the dryer internal duct Be sure not to pull or damage the electrical wires in...

Page 16: ... up before pressing Power Otherwise the display will not come on The dryer is now ready for use 3 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with the plate Kit WE49X22606 which can be purchased from GEApplianceparts com or a local service provider Place dryer in final location Plate Kit WE49X22606 NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE Kit WE4...

Page 17: ...rewdriver n Tape tipped putty knife n Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING THE DOOR SOLID DOOR MODELS 1 Open the door approximately 130 degrees With a putty knife remove the 4 plastic caps located along the left side of the front panel and set them aside 2 Remove the bo...

Page 18: ...ed in step 3 into the lower left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the original setup follow these instructions swapping left and right When you finish Plug the dryer back into its electrical outlet Door Hang door and tighten screws Plastic Cap 4 Right side of front pane...

Page 19: ...holes 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel Loosen each top hinge screw on right side B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 4 Remove both the blind plate and the strike plate and install them in the opposite positions 5 Remove the 4...

Page 20: ... you finish Plug the dryer back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 Remove and swap the 2 plastic caps and the 2 hinges 7 Rotate the outer door 180 degrees mount the inner door back into the outer door frame and secure with the screws removed in step 5 Make sure you mount the hinges on the side opposite the pocket Install...

Page 21: ...S A GAS ÚNICAMENTE ANTES DE COMENZAR Lea estas instrucciones por completo y con detenimiento IMPORTANTE Guarde estas instrucciones para el uso de inspectores eléctricos locales IMPORTANTE Cumpla con todos los códigos y ordenanzas vigentes Instale la secadora de acuerdo con las instrucciones del fabricante y los códigos locales Nota al instalador Asegúrese de dejar estas instrucciones con el consum...

Page 22: ...it Manguera corta adaptador en Y arandelas y WE1M847 Manguera Larga O POR SEPARADO WE1M847 Manguera Larga y WE1M848 Manguera Corta Instrucciones de instalación Incline la secadora de costado y saque los soportes de espuma de embalaje tirando de los costados y quitándolos de las patas de la secadora Asegúrese de quitar todas las piezas de espuma de las patas Saque la bolsa que contiene la informaci...

Page 23: ...r una explosión incendio o la muerte Esta secadora DEBE tener una ventilación al exterior El espacio libre mínimo entre el armario de la secadora y las paredes adyacentes u otras superficies es 0 sobre ambos lados 1 la parte trasera 1 sobre el frente 1 superior Se deberá considerar que se debe brindar el despeje adecuado para la instalación y el servicio técnico Las puertas del armario deben conta...

Page 24: ...asta que esté firmemente asentada 5 Asegúrese de que la arandela de goma plana se encuentra en su posición y coloque una manguera de entrada de agua de 4 a 6 pies de largo puede ser necesario comprarla por separado a un extremo macho del conector Y Apriete con la mano hasta que quede firmemente asentado 6 Asegúrese de que la arandela plana de goma se encuentre en su lugar y sujete el otro extremo ...

Page 25: ...gas y el material del conducto Válvula de cierre MATERIALES NECESARIOS Codo de metal de 4 diámetro Compuesto o PTFE cinta para tuberías Conector de tubería de gas flexible Abrazaderas de tubería 2 o abrazaderas de resorte 2 Gafas de seguridad Conducto de metal de 4 diámetro recomendado Guantes Solución jabonosa para detección de pérdidas Campana de salida Cinta aislante Gas adaptador 2 codo y tapó...

Page 26: ...da por CSA International Nunca vuelva a usar conectores flexibles viejos Instale una válvula de cierre manual individual dentro de 6 pies de la secadora en acuerdo con el Código Nacional de Gas Combustible ANSI Z223 1 NFPA 54 De forma segura ajuste todas las conexiones de gas Si la conexión fue realizada a gas LP solicite a una persona calificada que le asegure que la presión del gas NO supera una...

Page 27: ...ado del gas F Aplique compuesto para tubería o cinta PTFE en todas las roscas macho Válvula de apagado Toma a rosca CÓMO CONECTAR LA SECADORA AL SUMINISTRO DE GAS Instale un codo hembra NPT de 3 8 al final de la entrada de gas de la secadora Instale un adaptador de unión cónica de 3 8 al codo hembra IMPORTANTE Utilice una llave para tubos para sostener bien el extremo de la entrada de gas de la se...

Page 28: ...secadora está instalada en su posición final Si el circuito tiene un receptáculo de 2 clavijas es responsabilidad del propietario de reemplazarlo con un receptáculo de 3 clavijas debidamente conectado a tierra por un electricista autorizado INSTRUCCIONES DE CONEXIÓN A TIERRA Este secadora deberá estar conectado a tierra En caso de mal funcionamiento o avería la conexión a tierra reducirá el riesgo...

Page 29: ...RIAS Pinzas Nivel Conducto de metal flexible de 4 de diámetro si fuese necesario Kit de cable de energía de la secadora no incluido con la la secadora Clasificado UL de 120 240V 30A con 3 o 4 patas Identifique el tipo de enchufe según el tomacorriente de la vivienda antes de comprar el cable 4 Placa de cubierta Kit WE49X22606 si fuese necesario Destornillador de lados planos Destornillador Phillip...

Page 30: ... conectado a tierra En caso de mal funcionamiento o avería la conexión a tierra reducirá el riesgo de descargas eléctricas al brindar un camino con una resistencia menor para la corriente eléctrica Este secadora está equipada con un cable con un conductor para la conexión a tierra del equipo y un enchufe con conexión a tierra El enchufe deberá estar conectado a un tomacorriente instalado en forma ...

Page 31: ...través del alivio de tensión 5 Conecte el cable de energía de la siguiente manera A Conecte los dos cables vivos a los tornillos externos del bloque terminal marcado L1 y L2 B Conecte el cable neutral blanco al centro del bloque terminal marcado N 6 Asegúrese de que la cinta de conexión a tierra esté conectada a la terminal neutral central del bloque y al tornillo verde de conexión a tierra de la ...

Page 32: ...edan aplastar o doblar CONDUCTO DE TRANSICIÓN DE METAL FLEXIBLE SECADORA DE ROPA DE LA LISTA DE UL Si un conducto de metal rígido no puede ser utilizado entonces un conducto de metal flexible aprobado por UL puede ser utilizado GE Appliances parte PM08X10085 Nunca instale un conducto de transición en paredes cielos rasos pisos u otros espacios adjuntos La longitud total del conducto de transición ...

Page 33: ...rán ser considerados como un codo de 90 Para el escape lateral agregue un codo de 90 a la tabla Para cada codo adicional de 90 reduzca en 10 pies la longitud permisible del sistema de escape En el cálculo de la longitud total del sistema de ventilación debe agregar todas las partes rectas y codos del sistema incluyendo el conducto de transición LONGITUD DE SALIDA SALIDA AL EXTERIOR DE LA SECADORA ...

Page 34: ...a obstrucción con la abertura apuntando hacia abajo SEPARACIÓN DE CURVAS Para un mejor desempeño separe todas las curvas con 4 pies de conducto recto como mínimo incluyendo la distancia entre la última curva y la cubierta de pared con regulador de tiro SELLADO DE JUNTAS Todas las juntas deben estar bien selladas para evitar pérdidas El extremo macho de cada sección de conducto debe apuntar en dire...

Page 35: ...echa sólo modelos a eléctrico Izquierda Parte inferior Vuelva a conectar la porción cortada A del conducto a la caja del ventilador Asegúrese de que el conducto más corto se encuentre alineado con la lengüeta de la base Utilice el tornillo conservado con anterioridad para sujetar el conducto en su lugar a través de la lengüeta de la base del artefacto CÓMO AGREGAR CODOS Y CONDUCTOS DE SALIDA HACIA...

Page 36: ...A TRAVÉS DE LA PARTE INFERIOR DEL GABINETE NIVELE LA SECADORA ENCHUFE LA SECADORA 1 CONFIGURACIÓN FINAL 2 INICIO DE LA SECADORA Presione el botón Power Encendido NOTA Si la secadora ha sido expuesta a temperaturas bajo cero por un período prolongado deje que suba la temperatura antes de presionar Power De otra manera la pantalla no se encenderá Su secadora ya está lista para usar 3 SALIDA AL EXTER...

Page 37: ... punta cubierta con cinta n Destornillador de punta plana pequeña Antes de Comenzar Desenchufe la secadora del tomacorriente A INVERSIÓN DE LA PUERTA MODELOS DE PUERTA SÓLIDA 1 Abra la puerta aproximadamente 130 grados Con una espátula retire las 4 tapas de plástico ubicadas a lo largo del lado izquierdo del panel frontal y deje las mismas a un costado 3 Afloje cada tornillo de la bisagra superior...

Page 38: ... agujeros inferiores del lado izquierdo y apriete firmemente los cuatro tornillos 6 Instale las cuatro tapas de plástico retiradas en el paso 1 en los 4 agujeros del panel frontal derecho NOTA Para regresar la puerta a la configuración original siga estas instrucciones cambiando entre la izquierda y la derecha Al finalizar Vuelva a enchufar la secadora en la salida eléctrica Puerta Sostenga la pue...

Page 39: ...as mismas en posiciones opuestas Tapa de plástico 4 Lado izquierdo del panel frontal Placa ciega Placa de refuerzo 3 Afloje cada tornillo de la bisagra superior en el lado derecho Retire la puerta y coloque la misma sobre una superficie plana protegida a fin de evitar cualquier daño 2 Retire el tornillo inferior de cada bisagra lado derecho e inserte parcialmente en los agujeros de las bisagras de...

Page 40: ... a enchufar la secadora en la salida eléctrica Puerta Sostenga la puerta y ajuste los tornillos Tapa de plástico 4 Lado derecho del panel frontal B INVERSIÓN DE LA PUERTA MODELOS CON PANEL DE CRISTAL cont 6 Quite y cambie las 2 tapas de plástico y la bisagras de la puerta exterior 7 Gire la puerta exterior de 180 instale la puerta trasera interior en el exterior de la puerta con los tornillos que ...

Reviews: