GE GTD42GASJ0WW Installation Instruction Download Page 11

Summary of Contents for GTD42GASJ0WW

Page 1: ...oor Service information and the wiring diagram are located in the control console Do not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near children Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty Install the dryer where the temperature is above 50...

Page 2: ...y pulling at the sides and breaking them away from the dryer legs Be sure to remove all of the foam pieces around the legs Remove literature and bag containing accessories ROUGH IN 27 DIMENSIONS 68 8 cm Cubic y Foot 43 3 8 26 3 4 6 0 110 cm 68 cm 43 3 8 29 1 2 7 0 110 cm 75 cm 43 3 4 30 1 2 7 3 111cm 78 cm J Front View Y 4 Side View _ 4 1 4 10 8 cm X _14 s 8 1 7 cm STEAM WATER HOSES GEstrongly rec...

Page 3: ...ed immediately upstream of the gas supply connection to the dryer MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET INSTALLATION Minimum clearance to combustible surfaces and for air opening are 0 both sides 1 front 0 rear but a 1 minimum is recommended Consideration must be given to provide adequate clearance for installation and service MOBILE OR MANUFACTURED HOME INSTALLATION Installation must conf...

Page 4: ...oupling to one male end of the Y connector Tighten by hand until firmly seated Ensure the rubber flat washer is in attach the dryer s long inlet hose to end of the Y connector Tighten by firmly seated place and one male hand until Ensure the rubber flat washer is in attach the other end of the dryer s hose to the fill valve connector at the the dryer back panel Tighten by hand seated place and lon...

Page 5: ...nded 174 Cover Plate Kit WE1H454 174 dia UL listed flexible metal duct if needed 17Gloves 17Soap solution for leak detection 0 Exhaust hood 17Duct tape 17Gas pipe adapters 2 elbow and pipe plug o for electric dryers Before beginning the installation turn off the circuit breaker s or remove the dryer s circuit fuse s at the electrical box Be sure the dryer cord is unplugged from the wall Turn the d...

Page 6: ...onnect shall not exceed 3 ft for electric dryers cont GAS SUPPLY A 1 8 National Pipe Taper thread plugged tapping accessible for test gauge connection must be installed immediately upstream of the gas supply connection to the dryer Contact your local gas utility should you have questions on the installation of the plugged tapping Supply line is to be 1 2 rigid pipe and equipped with an accessible ...

Page 7: ...or Checking Gas Inlet Pressure Shut Off Valve ipe size at least 2 r_ Attach the flexible metal gas line connector to the adapter Apply pipe compound to the adapter and dryer gas inlet r_ Tighten the flexible gas line connection using two adjustable wrenches CONNECTING THE DRYERTO THE GAS SUPPLY cont Install a 1 8 NPT plugged tapping to the dryer gas line shut off valve for checking gas inlet press...

Page 8: ...or electrical shock ELECTRICAL CONNECTION INFORMATION FOR GAS DRYERS cont The dryer must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 This appliance must be supplied with 120V 60Hz and be connected to a properly grounded branch circuit protected by a 15 or 20 amp circuit...

Page 9: ... glasses 04 dia metal duct recommended O4 dia UL listed flexible metal duct if needed OGIoves O Exhaust hood 0 Duct tape O Dryer power cord kit not provided with dryer UL rated 120 240V 30A with 3 or 4 prongs Identify the plug type as per the house receptacle before purchasing line cord O4 Cover Plate Kit WE1H454 Before making the electrical connection turn off the circuit breaker s or remove the ...

Page 10: ...tion of the equipment grounding conductor can result in a risk of electrical shock Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the appliance is properly grounded DO NOT modify the plug on the power supply cord If it will not fit the outlet have a proper outlet installed by a qualified electrician SAVE THESE INSTRUCTIONS ELECTRICAL CON...

Page 11: ...curely 8 Properly secure power cord to strain relief 9 Reinstall the cover NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK CONNECTING DRYER USING 3 WIRE CONNECTION If required by local code install external ground not provided to grounded metal cold water pipe or other established ground determined by a qualified electrician Hot Wire Green Ground Screw Ground Strap Cover Fuse Strain 3 4 UL Relief ...

Page 12: ...N DUCT If rigid metal cannot be used then UL LISTEDflexible metal clothes dryer transition duct GE parts PIO8XlO085 WXO8XlO085 or WXO8XlO077 can be used Never install transition duct in walls ceilings floors or other enclosed spaces Total length of transition duct should not exceed 8 2 4 m For many applications installing elbows at both the dryer and the wall is highly recommended see illustration...

Page 13: ...H ALLOWABLE length of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted on the chart Internal elbows added for side or bottom vent conversions must be included in the total elbow count Any elbow greater than 45 should be treated as a 90 elbow Two 45 elbows will be treated like one 90 elbow For every additional 90 elbow reduc...

Page 14: ...for inspection and cleaning of the exhaust system especially at turns and joints Exhaust system shall be inspected and cleaned at least once a year INSULATION Ductwork that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint buildup BEFORE YOU BEGIN Remove and discard existing plastic or metal foil duct and replace with UL listed duct Remov...

Page 15: ...ow Fixing hole Cut the duct as shown and keep portion A 15 TAB LOCATION BENDTAB UP45 gas Through the rear opening locate the tab in the middle of the appliance base Lift the tab to about 45 using a flat blade screwdriver ADDING A NEW DUCT Fixing hole Portion A Right electric _ 1 k i _ y _ i modelsonly or _ I _ y left side exhaust _ _ _ _ Reconnect the cut portion A of the duct to the blower housin...

Page 16: ...y hazard ADDING COVER PLATE TO REAR OF CABINET Plate Kit WE1M4S4 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M4S4 available from your local service provider Place dryer in final location NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE Kit WEl1454 FINAL SETUP I I LEVEL THE DRYER Stand the dryer upright near the final location and adju...

Page 17: ...d putty knife Small flat blade screwdriver Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions rA or r_ for your model F_ REVERSING THE DOOR SOLID DOOR MODELS r_ open the door 130 With approximately degrees a putty knife remove the 4 plastic caps located along the left side of the front panel and set them aside Plastic Cap 4 Left side of front panel 17 REVERSING ...

Page 18: ... step 3 into the lower left side screw holes and firmly tighten all 4 screws Hang door and tighten screws Door 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes Plastic Cap 4 Right side of _ _ _ front panel NOTE To return the door to the original setup follow these instructions swapping left and right When you finish Plugthe dryer back into its electrical outle...

Page 19: ...front panel hinge screws will now be in the top hinge holes 2 on the left and 2 on the right 31Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage Loosen each top hinge screw on right side S FB1REVERSING THE DOOR GLASS PANEL DOOR MODELS cont r4 Remove both the blind plate and the strike plate and install them in the opposite posit...

Page 20: ...Pocket screws Inside screws Door hinge __ _ rews Ins Inside screw Inside screw REVERSING THE DOOR GLASS PANEL DOOR MODELS cont F8 Mount the assembled door on the 2 upper left side hinge screws installed in step 2 Move the hinge screws loosened in step 2 into the lower left side screw holes and firmly tighten all 4 screws Hang door and tighten screws Door rg install the 4 plastic caps removed in st...

Page 21: ...del cableacloseencuentran en la consola de control No permita que niBossesuban o se metan dentro del artefacto Serequiere una supervisi6nestricta cuando el aparato es utilizado cerca de ninos Elinstalador tiene la responsabilidadde efectuar una instalaci6n adecuada La garant a no cubre las fallas del producto debido a una instalaci6n incorrecta Instale la secadora en lugaresdonde la temperatura se...

Page 22: ...it6ndolos de las patas de la secadora AsegOrese de quitar todas las piezas de espuma de las patas Saque la literatura y la balsa que contiene la informaci6n DIMENSIONES APROXIMADAS Pie C6bico Y 43 3 8 26 3 4 6 0 110 cm 68 cm 43 3 8 29 1 2 7 0 110 cm 75 cm 43 314 30 1 2 7 3 iiicm 78cm 27 68 8 cm Visi6n frontal X Visi6n lateral 4 1 4 10 8 cm X b_ 4 5 8 1 7 cm MANGUERA DE VAPOR V AGUA GE recomienda e...

Page 23: ...ispositivo de calibraci6n deber6 ser instalada inmediatamente arriba de la conexi6n del suministro de gas a la secadora ESPACIO LIBRE MJNIMO EN OTROS ESPACIOS QUE NO SEAN INSTALACIONES EN NICHOS 0 ARMARIOS Los espacios libres minimos respecto de superficies combustibles y de aberturas de aire son O a ambos lados 1 2 54 cm en el frente O en la parte trasera pero 1 2 54 cm minimo es la recomendada D...

Page 24: ... a mano hasta que est6 firmemente asentada AsegOrese de que la arandela plana de goma se encuentre en su lugar y sujete la manguera larga de entrada de la secadora a un extremo macho del conector en V Ajuste a mano hasta que est6 firmemente asentada Aseg0rese de que la arandela plana de goma se encuentre en su lugar y sujete el otro extremo de la manguera larga de entrada al conector de la v61vula...

Page 25: ...dad OConducto de metal flexible de 4 di6metro si fuese necesario OGuantes OSoluci6n jabonosa para detecci6n de p didas OCampana de salida OCinta aislante O Conducto de metal de 4 di6metro recomendado 04 Placa de cubierta Kit WE1M454 OGas adaptador 2 codo y tap6n de tuberfa Antes de comenzar la instalaci6n apague el disyuntor o quite los fusibles de la secadora de la caja el6ctrica Verifique que el...

Page 26: ...UMINISTRO DE GAS Debe instalarse una toma a rosca de 1 8 NPT accesible para una conexi6n del man6metro de prueba inmediatamente en sentido ascendente de la conexi6n de suministro de gas hacia la secadora Sitiene dudas sobre la instalaci6n de la toma comuniquese con su empresa proveedora de gas local La linea de suministro debe set de tuberia rigida de 1 2 y debe contar con un cierre accesible dent...

Page 27: ...cierre k_4r _ _ Ta maffo de tuberia al menos 1 2 Los productos que no suministrados r_ una el conector de tuberia de gas de metal flexible al adaptador Aplique compuesto para tubena al adaptador y a la entrada de gas de la secadora r_ Ajuste la conexi6n de tuberia flexible de gas utilizando dos Ilaves ajustables c6Ho CONECTAR LA SECADORA AL SUHINISTRO DE GAS cont Instale una toma a rosca de 1 8 NP...

Page 28: ...as el6ctricas CONE I6N ELI_CTRICA INFORMACI6N SOBRE LAS SECADORAS A GAS cont La secadora debe contar con una conexi6n el6ctrica a tierra en cumplimiento con los c6digos locales o si 6stos no existieran de acuerdo con el C6digo EI6ctrico Nacional ANSI NFPA 70 o el C6digo EI6ctrico Canadiense CSA C22 1 Este artefacto debe contar con un suministro de 120V 60Hz debe estar conectado a un circuito deriv...

Page 29: ...cto de metal de 4 de di6metro recomendado 17Conducto de metal flexible de 4 de di6metro si fuese necesario OCampana de salida OCinta aislante 17Kit de cable de energia de la secadora no incluido con la secadora Clasificado UL de 120 240V 30A con 3 o 4 patas Identifique el tipo de enchufe segOn el tomacorriente de la vivienda antes de comprar el cable O4 Placa de cubierta Kit WE1M4S4 Antes de efect...

Page 30: ...ada del conductor de canexi6n a tierra del equipa puede pravacar riesgas de descargas el ctricas Consulte a un electricista calificada a personal o representantes del servicia t cnicasi tiene dudas de que el electradom6stico se encuentre conectada a tierra apropiadamente NO modifique el enchufe en el cable de suministro de corriente Si no coincide can la toma de carriente contrate a un electricist...

Page 31: ...oque terminal 8 Ajuste bien el cable de energ a al alivio de tensi6n 9 Vuelva a instalar la tapa NUNCA OLVIDE DE VOLVER A COLOCAR LA TAPA DEL BLOQUE TERMINAL COMa CONECTAR LA SECADORA UTILIZANDO UNA CONE I6N DE 3 CABLES Sias Io requirieran los c6cligos locales instale una conexi6n a tierra externa no provista a metal con cone i6n a tierra tuber as de agua fr a con conexi6n a tierra u otra cone i6n...

Page 32: ...DE TRANSICI6N DE METALFLEXIBLE SECADORADE ROPA DE LA LISTADE UL Si un conducto de metal rigido no puede ser utilizado entonces un conducto de metal flexible aprobado por UL puede ser utilizado GE partes PM08X10085 WX08X10085 o WX08X10077 Nunca instale un conducto de transici6n en paredes cielos rasos pisos u otros espacios adjuntos La tongitud total del conducto de transici6n no deber6 superar los...

Page 33: ...AXIMA PERMITIDAdel sistema de salida depende del tipo de conducto la cantidad de curvas la clase de campana de salida cubierta de pared y todas las condiciones indicadas en el gr6fico Codos internos agregados para conversiones de ventilaci6n lateral o inferior se deber6n incluir en la cuenta total de los codas Cualquier codo superior a 45 deberia set considerado como un codo de 90 Dos codos de 45 ...

Page 34: ...r pie Incluya un acceso para inspecci6n y limpieza del sistema de salida especialmente en las curvas Inspeccione y limpie el conducto par Io menos una vez al a_o AISLACl6N Los conductos instalados a trav6s de una 6tea sin calefacci6n o ubicados cerca de un acondicionador de aire deben aislarse para reducir la condensaci6n y la acumulaci6n de pelusas ANTES DE COMENZAR Quite las pelusas de la abertu...

Page 35: ...I_ o z 26 Corte el conducto como puede verse y conserve la porci6n A UBICACI6N DE LA LENGUETA para gas Gire la lengOeta hasta 45 A trav6s de la abertura trasera ubique la leng0eta en el medio de la base del artefacto Levante la lengOeta hasta alrededor de 4S utilizando un destornillador de lados pianos C6MO AGREGAR UN CONDUCTO NUEVO Orificiode montaje Derech I Porci6n A Derecha s61o modelos a el c...

Page 36: ...rovocar un riesgo de seguridad C6MO AGREGAR LA PLACA DE CUBIERTA A LA PARTE TRASERA DEL GABINETE Conecte los codos y conductos de metal est6ndar para completar el sistema de salida Cubra la abertura trasera con la placa Kit WEIM4S4 disponible en su proveedor de servicios local Coloque la secadora en su ubicaci6n final NUNCA DEJE LA ABERTURA TRASERA SIN LA PLACA EN SU LUGAR Kit WEIM454 J CONFIGURAC...

Page 37: ...n cinta Destornillador de punta plana pequeha Antes de Comenzar Desenchufeta secadoradet tomacorriente alas INVERSI6NDELA PUERTAinstrucciones or r_ para su modelo INVERSI6N DE LA PUERTA MODELOS DE PUERTA S6LIDA rT1Abra la puerta aproximadamente 130 grados Con una esp6tula retire las 4 tapas de pl6stico ubicadas a Io largo del lado izquierdo del panel frontal y deje las mismas a un costado Tapa de ...

Page 38: ... paso 3 hacia los agujeros inferiores del lado izquierdo y apriete firmemente los cuatro tornillos Sostenga la puerta y ajuste los tornillos Puerta X h 6 Instole los cuatro topos de pl6stico retiradas en el paso en los 4 agujeros del panel frontal derecho Tap de NOTA Para regresar la puerto a la configuraci6n original siga estas instrucciones cambiando entre la izquierda y la derecha AI finalizar ...

Page 39: ...s de la bisagra superior 2 sobre la izquierda y 2 sobre la derecha _Afloje cada tornillo de la bisagra superior en el lado derecho Retire la puerta y coloque la misma sobre una superficie plana protegida a fin de evitar cualquier daflo Afloje cada tornillo de la bisagra superiors en el lado derecho IBI INVERSI6N DE LA PUERTA MODELOS CON PANEL DE CRISTAL cont r_ Retire la placa ciega y la placa de ...

Page 40: ... _ _ _ _ ___uerta _ l Tornill _ _ nterno interno Tornillo interno rB INVERSI6N DE LA PUERTA MODELOS CON PANEL DE CRISTAL cont r 8 Monte la puerta sabre los 2 tornillos superiores del lado izquierdo instalados en el paso 2 Mueva los tornillos de la bisagra aflojados en el paso 3 hacia los agujeros inferiores del lado izquierdo y apriete firmemente los cuatro tornillos SostengoIn puerto y ojuste los...

Reviews: