background image

6

Installation Instructions.

Feed Water Supply

Check and comply with local plumbing codes 

as you plan, then install a cold 

feed water supply fitting. For new home installation using standard plumbing

fittings, see first two illustrations below. A typical installation for existing

homes using the saddle valve is shown in third illustration below.

A. PREFERRED INSTALLATION

Turn off the cold water supply.
Complying with plumbing codes, install a fitting on the cold water pipe to

adapt 3⁄8

OD tubing. A typical connection is shown in illustrations at right

(parts not included). Make sure a water supply valve is used.

2

1

B. OPTIONAL HOME INSTALLATION 

Where codes permit

*For 1/2" OD or larger metal tubing only.

NOTE: Codes in the state of Massachusetts require installation by a licensed 
plumber and do not permit the use of the saddle valve. For installation, use 
plumbing code 248-CMR of the Commonwealth of Massachusetts.

Turn off the cold water supply and attach saddle valve as shown in

illustration at right.

DANGER: 

To protect yourself from serious injury or fatal shock, 

use a battery powered hand drill only to make the hole. 

DO NOT USE AN ELECTRIC DRILL. 

Close the water supply valve by turning the handle clockwise. 
Open the main water supply valve and several house faucets to 

purge air from the system. Close faucets when water runs smoothly.

3

2

1

Optional water supply connection (using saddle valve)*

*For 1/2" OD or larger metal tubing only.

Pre-drill
1⁄4

hole

Seal—make sure the
seal is in place

Clamp X

Nut (2)—not
required if holes in
clamp are threaded

Valve

Handle

Tubing adapter

Washer

Compression nut

Clamp Z

Preferred water supply connection
(using compression fitting)

Insert (not included)

Cold
water
pipe

3/8

tubing to inlet

Ferrule

Water supply valve

Typical location

Cold
water

Use to connect the tubing

Some threads
should be visible

Rubber gasket

Snug valve into
bracket. 

DO NOT

OVERTIGHTEN.

Summary of Contents for GN1S15CBL (REV. 2)

Page 1: ...inst ANSI NSF Standard 42 for the reduction of Particulate Class I Chlorine Class I and Taste Odor and Standard 53 for the reduction of Lead Cyst Turbidity Asbestos and VOC www geappliances com Safety Information 2 Operating Instructions 3 4 Specification Guidelines 3 Using the System 4 Installation Instructions 5 11 Battery Pack Installation 8 Faucet Installation 7 8 Feed Water Supply 6 Filter Ca...

Page 2: ...not purify the water or make it safe to drink Do not use on a hot water supply 100 F max WARNING Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts PROPER INSTALLATION This Water Filtration system must be properly...

Page 3: ...no end caps Filter II White with yellow end caps Reduces dirt rust and sediment Reduces unpleasant tastes and odors Reduces Chlorine Reduces Lead Reduces Asbestos Reduces filterable cysts such as cryptosporidium and giardia Reduces Lindane a pesticide 0 5 micron nominal particulate reduction For Models GNSV25CBL GNSV30CWW and GNSV30CCC FXSVC Filter Set 540 Gallon Capacity Filter I White with gray ...

Page 4: ...ase the cartridges should be replaced immediately If the system is also for lead or chemical contaminant removal it is MORE IMPORTANT to replace the cartridges at least every six months NOTE If the water supply contains high amounts of sediments the carbon filters may plug prematurely reducing filtered water flow to the system faucet Cartridge replacement is needed to restore flow Electronic Indic...

Page 5: ... drill and 1 4 bit saddle valve installation Electric drill and drill bit to drill 1 1 1 4 hole type as required if mounting hole is needed for faucet CAUTION To avoid damaging the sink consult a qualified plumber or installer for drilling procedures Special drill bits may be needed for porcelain or stainless steel Contents included with the product Water filter assembly including mounting bracket...

Page 6: ...on use plumbing code 248 CMR of the Commonwealth of Massachusetts Turn off the cold water supply and attach saddle valve as shown in illustration at right DANGER To protect yourself from serious injury or fatal shock use a battery powered hand drill only to make the hole DO NOT USE AN ELECTRIC DRILL Close the water supply valve by turning the handle clockwise Open the main water supply valve and s...

Page 7: ...lace small gasket base and large gasket in that order onto the faucet stem Next place lock washer and hex nut onto faucet stud Insert washer into tubing adapter Securely tighten to faucet stud Feed the length of 3 8 OD tube from the bottom up through the mounting hole Connect to the tubing adapter as shown in second illustration tightening the compression nut securely Remove the short shipping tub...

Page 8: ...en both screws until the base is held firmly in place Do not overtighten and break the base Assemble the top faucet base and hex nut onto the faucet stud third illustration Tighten the nut until snug Insert washer into tubing adapter Securely tighten to faucet stud Feed the length of 3 8 OD tubing from the bottom up through the faucet base Connect to the tubing adapter as shown in fourth illustrat...

Page 9: ...ng Insert the plastic tubing all the way to the bottom of the elbow Tubing must be fully inserted to avoid leaks Slide nut up to the elbow and thread on by hand until tight Repeat the procedure to connect the tubing between the filter system inlet and the water supply saddle valve illustration in the Installation Overview section IMPORTANT Be sure to check for leaks at all connections Tighten as n...

Page 10: ...5 4 3 2 1 Filter I Filter II O ring seal Cartridge Sump II Sump Sump I Label TURN SUMP TO INSTALL TURN SUMP TO REMOVE Head Bracket Turn sump wrench tool provided clockwise to remove sump OUTLET INLET Lightly lubricate the o ring seal in the sump with clean food grade silicone grease silicone grease is available through GE Parts and Services 1 800 626 2002 Part Number WS60X10005 Be sure it is fully...

Page 11: ...er faucet Then check for leaks between the sump and the head NOTE If leaking turn off the water supply and turn on the filtered water faucet Disassemble the filter housing and check the o ring for cuts flat spots etc and sealing surfaces for foreign material Clean the o ring and lightly lubricate with clean silicone grease Carefully press into the groove in the sump Reassemble and check for leaks ...

Page 12: ...nd install replaced or they may have been correctly Replace batteries if they are old installed incorrectly Leadwires damaged Inspect and repair as needed Chlorine taste and or The filter cartridges are no Replace both filter cartridges odor in the product water longer removing chlorine from the water supply Water dispenses Filter may have an integral A slower flow approx 0 6 g min is normal with ...

Page 13: ... WS07X10008 TUBING 3 8 X 20 FT WH 1 1 1 1 0014 WS02X10004 NUT 3 8 2 2 2 2 0015 WS03X10003 ADAPTER TUBING 2 2 2 2 0016 WS03X10002 WASHER 2 2 2 2 0017 WS15X10008 SADDLE VALVE SUPPLY 1 1 1 1 0018 WS15X10002 FAUCET ASM monitored BLACK ON CHROME 1 1 WS10X10020 FAUCET ASM monitored WHITE ON WHITE 1 WC10X10001 FAUCET ASM monitored BISQUE 1 0019 WS10X10008 TOP FAUCET BASE BLACK 1 1 WS10X10010 TOP FAUCET B...

Page 14: ... WH 1 0014 WS02X10004 NUT 3 8 2 0015 WS03X10003 ADAPTER TUBING 2 0016 WS03X10002 WASHER 2 0017 WS15X10008 SADDLE VALVE SUPPLY 1 0018 WS15X10022 FAUCET ASM nonmonitored BLACK ON CHROME 1 0025 FXULC FILTER LEAD CYST 1 0200 WX5X140 WRENCH SUMP 1 0999 49 50057 PM MANUAL USE CARE INSTALLATION 1 14 Parts List Saddle Valve NOTE Codes in the state of Massachusetts require installation by a licensed plumbe...

Page 15: ...15 Notes ...

Page 16: ...amages This warranty gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company Louisville KY 40225 16 Service Telephone Numbers GE Answer Center 800 626 2000 The GE Answer Center is open 24 hours a day 7 d...

Reviews: