Motor Pump Assembly
The motor pump assembly is located under the tub
behind the sump assembly. The motor utilizes a
start capacitor rated at 10
fd. The motor rotates
clockwise (as viewed from the terminal end) and
draws approximately 1 amp at 120 VAC.
The motor pump assembly has an approximate
resistance value of 17
.
Operation of the motor pump assembly can be
checked by using the service test mode. (See
Service
Test Mode
.)
To remove the motor pump assembly:
1. Disconnect
power.
2. Open the dishwasher door and remove the
bottom rack.
3. Remove the dishwasher from its installation.
4. Lay the dishwasher on its back.
Caution:
The clamps are easily damaged during
removal and should not be reused.
5. Disconnect the motor ground wire.
Note: Factory-installed hose clamps are not
reusable. When installing a water inlet valve, drain
pump assembly, motor pump assembly, or sump
assembly, replace the old clamps with new screw-
type hose clamps provided. The screw-type hose
clamps are available separately.
6. Remove clamp and outlet hose.
(Continued next page)
7. Cut off the wire tie and disconnect the motor
wire harness.
8. Remove 2 clamps, pump interconnect hose, and
outlet hose.
9. Remove the Phillips-head screw, lock washer,
and washer that attach the motor bracket to the
back rail.
10. Pull the motor bracket off the motor tab.
Motor Tab
Motor Bracket
Clamp Part Number
Size
WD01X10322
15/16" to 1-1/2"
Motor Bracket
Back Rail
Ground Wire
Outlet Hose
Wire Harness
Interconnect
Hose
Outlet Hose
Wire Tie