GE GLD6500LWW/CC/BB Installation Instructions Manual Download Page 3

Method 1 – Air Gap with Waste Tee or Disposer 

An air gap must be used when required by local codes and ordi-
nances. The air gap must be installed according to manufacturer’s 
instructions.

PREPARE DISHWASHER  ENCLOSURE

• The rough cabinet opening must be at least 24" deep, 24" 

wide and approximately 34-1/2" high from floor to underside 
of the countertop. 

CLEARANCES: 

 When 

installed into a corner, 
allow 2" min. clearance 
between dishwasher 
and adjacent cabinet, 
wall or other appliances. 
Allow 28-3/8" min. clear-
ance from the front of 
the dishwasher for door 
opening. Figure B

DRAIN REQUIREMENTS

• Follow local codes and ordinances.
• Do not exceed 10' distance to drain.

NOTE:

Air gap must be used, if waste tee or disposer 

connection is less than 18" above floor to prevent siphoning.

DETERMINE DRAIN METHOD

The type of drain installation depends on the following 

questions.

® 

Do local codes or ordinances require an air gap?

® 

Is waste tee less than 18" above floor?

If the answer to either question is YES, Method 1 MUST 

be used.

• If the answers are NO, either method may be used. 

CABINET PREPARATION

• Drill a 1-1/2" diameter hole in the cabinet wall within 

the shaded areas shown in Figure A for the drain hose 

connection. The hole should be smooth with no sharp edges.

IMPORTANT

 – 

When 

connecting drain line to disposer, 
check to be sure that drain plug has 
been removed. DISHWASHER WILL 
NOT DRAIN IF PLUG IS LEFT IN PLACE.

Method 2 – “High Drain Loop” with Waste Tee or Disposer

Tip: Avoid unnecessary service call charges

Always be sure disposer drain plug has been removed before 

attaching dishwasher drain hose to the disposer.

661Dia43

Figure D

• The dishwasher must be installed so that drain hose is no 

more than 10' in length for proper drainage.

• The dishwasher must be fully enclosed on the top, sides and 

back, and must not support any part of the enclosure.

24" 

Min.

This Wall Area 

must be Free 

of Pipes or 

wires

Plumbing and Electric Service 

Must Enter Inside This Area

34-1/2"1/4"

Underside of 

Countertop

to Floor

4"

24"

Min.

6"

5"

5"

4"

Cabinets

Square

and

Plumb

Floor MUST be Even

With Room Floor.

612Dia41

923-40B 

32" 

Min. 

18" 

Min. 

Drain Hose Hanger 

Figure B

756Dia30 

Clearance for Door 

Opening 2" Minimum 

Countertop 

Dishwasher 

28-3/8" 

Figure C

Installation Preparation

3

Remove

Drain

Plug

1871 Art1

#282 French

WARNING

To reduce the risk of electric shock, 

fi re, or injury  to persons, the installer 

must ensure that the dishwasher is 

completely enclosed at the time of 

installation.

661Dia42

32"

Min.

18"

Min.

05D-1294B

Drain Hose Hanger

Summary of Contents for GLD6500LWW/CC/BB

Page 1: ...let gloves safety glasses or goggles should be worn READ CAREFULLY KEEP THESE INSTRUCTIONS IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions fo...

Page 2: ...ips special head screws to Two 8 18 x 5 8 Phillips special head screws to secure dishwasher to underside of countertop Junction box cover and 10 hex head screw Junction box cover and 10 hex head screw...

Page 3: ...n in Figure A for the drain hose connection The hole should be smooth with no sharp edges IMPORTANT When connecting drain line to disposer check to be sure that drain plug has been removed DISHWASHER...

Page 4: ...th 120V 60 Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground and rated for 75 C 176...

Page 5: ...accessible location such as under the sink Optional but strongly recommended and may be required by local codes Water connection is on the left side of the dishwasher Install the hot water inlet line...

Page 6: ...rise from the full open position If necessary increase or decrease tension as shown Latch door and adjust both springs to the same tension setting to correct balance Tip Make sure door opens and close...

Page 7: ...ket Insert power cord through strain relief and tighten Make sure black white and green dishwasher wires are threaded through small hole in junction box bracket Connect power cord white or ribbed to d...

Page 8: ...ABINET IMPORTANT Do not push against front panel with knees Damage will occur Grasp the sides of the front panel and slide dishwasher into the opening a few inches at a time As you proceed pull the dr...

Page 9: ...OUNT BRACKETS Skip this step if underside of countertop is wood or wood like material Install side mount brackets if underside of countertop is granite or similar material that will not accept wood sc...

Page 10: ...ed the 2 Phillips special head screws from the screw kit set aside in Step 1 The dishwasher must be secured to the countertop or the cabinet sides When the underside of the countertop is wood use Meth...

Page 11: ...f 120 10 feet to the factory installed hose Use 5 8 or 7 8 inside diameter hose and a coupler to connect the two hose ends Secure the connection with hose clamps Figure W Figure X Note TOTAL DRAIN HOS...

Page 12: ...k door alignment with cabinet If door hits cabinet Check door alignment with cabinet If door hits cabinet reposition dishwasher See Step 15 Check that door spring does not contact water line fill hose...

Page 13: ...after The dishwasher will drain and turn off about 5 minutes after it was started Check drain lines If leaks are found turn off power at the breaker and correct plumbing as necessary Restore power af...

Page 14: ...Notes...

Page 15: ...Notes 14...

Page 16: ...sumer Industrial General Electric Company Louisville Kentucky 40225 ge com 2005 General Electric Company Pub No 31 30217 Dwg No 206C1559P157 ND 06G 1871 8 06 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT N...

Reviews: