WARNING 

RISK OF FIRE

• To reduce the risk of severe injury or death, follow all installation 

instructions.

• Clothes dryer installation must be performed by a qualified installer.

• Install the clothes dryer according to these instructions and in 

accordance with local codes.

• This dryer must be exhausted to the outdoors.

• Use only rigid metal 4” diameter ductwork inside the dryer cabinet and use 

only UL approved transition ducting between the dryer and the home duct.

• DO NOT install a clothes dryer with flexible plastic ducting materials. If 

flexible metal (semi-rigid or foil-type) duct is installed, it must be UL listed 

and installed in accordance with the instructions found in “Connecting 

The Dryer To House Vent” on pages 4-5 of this manual. Flexible venting 

materials are known to collapse, be easily crushed, and trap lint. These 

conditions will obstruct dryer airflow and increase the risk of fire.

• Do not install or store this appliance in any location where it could be 

exposed to water and or weather.

• Save these instructions. (Installers: Be sure to leave these instructions 

with the customer).

NOTE: Installation and service of this dryer requires basic

mechanical and electrical skills. It is your responsibility to

contact a qualified installer to make the electrical connections.

Installation

Instructions

Electric Dryer

10

Questions on Installation? Call: 1-800-GECARES (US)

or Visit our Web site at: 

www.GEAppliances.com (US)

BEFORE YOU BEGIN

Read these instructions completely and

carefully.

IMPORTANT-

 Save these instructions 

for local inspector’s use.

IMPORTANT-

 Observe all  governing 

codes and ordinances.

 Note to Installer - Be sure to leave these

instructions with the customer.

• Note to Customer - Keep these instructions 

with your Use and Care Book for future 

reference.

• Before the old dryer is removed from service 

or discarded, remove the dryer door.

• Service information and the wiring diagram 

are located in the control console.

• Do not allow children on or in the appliance. 

Close supervision of children is

necessary when the appliance is used

near children.

• Install the dryer where the temperature

is above 50°F for satisfactory operation of

the dryer control system.

TOOLS YOU

WILL NEED

PHILLIPS SCREWDRIVER

SLIP JOINT PLIERS

LEVEL

FLAT BLADE SCREWDRIVER

MATERIALS YOU WILL NEED

GLOVES

SAFETY

GLASSES

DRYER POWER

CORD KIT

(NOT PROVIDED

WITH DRYER)

4" DUCT

CLAMPS (2)

OR

4" SPRING

CLAMPS (2)

EXHAUST

HOOD

3/4" STRAIN

RELIEF

UL RECOGNIZED

4" DIA. ME TAL

ELBOW

4" DIA. FLEXIBLE METAL (SEMI-RIGID)

UL LISTED TRANSITION DUCT

(IF NEEDED)

 KIT WX08X10077 (INCLUDES 2 ELBOWS)

4" DIA. METAL DUCT

(RECOMMENDED)

4" DIA. FLEXIBLE METAL (FOIL TYPE)

UL LISTED TRANSITION DUCT

(IF NEEDED.)

DUCT TAPE

UL RATED 

120/240V,30A       

WITH 3 OR 4 PRONGS. 

IDENTIFY THE PLUG 

TYPE AS PER THE 

HOUSE RECEPTACLE 

BEFORE PURCHASING 

LINE CORD. 

4” COVER PLATE (IF NEEDED

(KIT WE1M454)

31-16629-1  03-11  GE

234D1052P003

Step 1  Prepare the area and exhaust for installation of new dryer 

(see section 1).

Step 2  Check and ensure the existing external exhaust is clean (see 

section 1) and meets attached installation specifications (see 

section 3).

Step 3  Remove the foam shipping pads (see section 1).

Step 4  Move the dryer to the desired location.

Step 5  Connect the power supply (see section 2).

Step 6  Connect the external exhaust (see section 4).

Step 7   Level your dryer (see section 5).

Step 8  Check the operation of the power supply and venting.

Step 9  Place the owners manual and the installation instructions in 

a location where they will be noticed by the owner.

For alcove or closet installation, see section 6.

For bathroom or bedroom installation, see section 7.

For mobile or manufactured home, see section 8.

For side or bottom exhaust, see section 9.

Summary of Contents for GFDN240ELWW

Page 1: ...d Care Book for future reference Before the old dryer is removed from service or discarded remove the dryer door Service information and the wiring diagram are located in the control console Do not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near children Install the dryer where the temperature is above 50 F for satisfactory operation...

Page 2: ...nized strain relief to power cord entry hole Bring power cord through strain relief 6 Connect power cord as follows A Connect the 2 hot lines to the outer screws of the terminal block marked L1 and L2 B Connect the neutral white line to the center of the terminal block marked N 7 Attach ground wire of power cord with the green ground screw hole above strain relief bracket Tighten all terminal bloc...

Page 3: ...rafts or entry of birds or other wildlife Termination should present minimal resistance to the exhaust air flow and should require little or no maintenance to prevent clogging Never install a screen in or over the exhaust duct This could cause lint build up Wall caps must be installed at least 12 in above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For b...

Page 4: ...er than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do not obstruct incoming or ex...

Page 5: ...ST WALL DO NOT SIT DRYER ON FLEXIBLE EXHAUST 5 LEVEL SIDE TO SIDE 4 LEVELING LEGS LEVEL FRONT TO BACK Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear For many applications installing elbows at both the dryer and the wall is highly recommended see illustrations below Elbows allow the ...

Page 6: ...se the screw saved previously to secure the duct in place through the tab on the appliance base RIGHT OR LEFT SIDE EXHAUST PORTION A FIXING HOLE 7 BATHROOMORBEDROOMINSTALLATION The dryer MUST be vented to the outdoors See EXHAUST INFORMATION section 3 4 The installation must conform with local codes or in the absence of local codes with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 MOBILE OR MANUFA...

Page 7: ... BE ADDED TO LEFT OR RIGHT SIDE DUCT TAPE DUCT TAPE CAUTION Use 4 rigid metal ducting only inside the dryer Internal duct joints must be secured with tape otherwise they may sepa rate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET SIDES AND BOTTOM EXHAUST Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available fr...

Page 8: ......

Page 9: ...ervicio o eliminada quítele la puerta La información sobre reparaciones y el diagrama del cableado se encuentran en la consola de control No permita que niños se suban o se metan dentro del aparato Se requiere una super visión estricta cuando el aparato es utilizado cerca de niños Instale la secadora en lugares donde la temperatura sea mayor a 50 F para un funcionamiento satisfactorio del sistema ...

Page 10: ...cable de energía Pase el cable de energía a través del alivio de tensión 6 Conecte el cable de energía de la siguiente manera A Conecte los dos cables vivos a los tornillos externos del bloque terminal marcado L1 y L2 B Conecte el cable neutral blanco al centro del bloque terminal marcado N 7 Conecte el cable a tierra del cable de energía con el tornillo verde de conexión a tierra orificio sobre e...

Page 11: ...la salida de modo de evitar contracorrientes o el ingreso de pájaros u otros insectos o animales La boca de salida debe presentar una resistencia mínima al flujo de salida y debe requerir poco o ningún mantenimiento para evitar las obstrucciones Nunca instale un filtro dentro o sobre el conducto de salida Esto podría provocar una acumulación de pelusa Las cubiertas de pared deben instalarse por lo...

Page 12: ... de salida Los conductos más largos acumulan pelusa lo que genera un riesgo potencial de incendio Nunca instale un filtro dentro o sobre el conducto de salida Esto provocará la acumulación de pelusas lo que genera un riesgo potencial de incendio No arme la red de conductos con sujeciones que se extiendan dentro del conducto Estas sujeciones pueden acumular pelusa lo que genera un riesgo potencial ...

Page 13: ... SALIDA FLEXIBLE CONTRA LA PARED NO COLOQUE LA SECADORA SOBRE UNA SALIDA FLEXIBLE 5 NIVELAR LADO A LADO 4 PATAS DE NIVELACIÓN NIVELAR FRENTE A PARTE TRASERA Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear Para muchas aplicaciones se recomienda enfáticamente la instalación de codos en...

Page 14: ...a de la base Utilice el tornillo conservado con anterioridad para sujetar el conducto en su lugar a través de la lengüeta de la base del artefacto SALIDA LATERAL POR DERECHA O IZQUIERDA PORCIÓN A ORIFICIO DE MONTAJE 7 INSTALACIÓN EN BAÑOS O DORMITORIOS Esta secadora DEBE tener una ventilación al exterior Ver la INFORMACIÓN SOBRE SALIDA secciones 3 y 4 La instalación debe cumplir con códigos locale...

Page 15: ... LOS LADOS DERECHO O IZQUIERDO CINTA AISLANTE CINTA PRECAUCIÓN Utilice un conducto de metal rígido de 4 sólo dentro de la secadora Las juntas del con ducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad CÓMO AGREGAR LA PLACA DE CUBIERTA A LA PARTE TRASERA DEL GABINETE SALIDAS POR LOS LADOS Y LA PARTE INFERIOR Conecte los codos y conductos de met...

Page 16: ......

Reviews: