GE GFDN110ED1WW Installation Instructions Manual Download Page 2

Summary of Contents for GFDN110ED1WW

Page 1: ...plastic ducting materials If flexible metal semi rigid or foil type duct is installed it must be UL listed and installed in accordance with the instructions found in Connecting The Dryer To House Vent on pages 4 5 of this manual Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct dryer airflow and increase the risk of fire Do not install ...

Page 2: ... constructions utilize a 4 wire connection to an electric dryer Wire according to the terminal block illustration that matches your dryer Relocatre Green green ground Hot Wire Screw Wire screw here Screw Remove ground strap and Keep green ground screw white Hot Wire Strain 3 4 UL Relief Screw Recognized Bracket Strain Relief 4 10 AWG minimum conductors or 20 240V 30A power supplycord kit marked fo...

Page 3: ...zed Relief spade terminals Strain Relief Bracket with upturned ends not supplied S wire Connection Not for use in Canada DO NOTuse for Mobile Home Installations NOTfor use on new construction NOTfor use on recreational vehicles NOTfor use in areas where local codes prohibit grounding through the neutral conduction 1 Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the el...

Page 4: ...is shown inthe table below EXHAUST SYSTEM CHECK LIST No of 90 Elbows 0 1 2 3 4 EXHAUST LENGTH RECOMMENDED lvtAXIiVlUivtLENGTH Exhaust Hood Types Recommended Rigid Metal 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet Use only for short run installations 4 DIA _ i _ 2 1 2 Rigid Metal 60 Feet 45 Feet 35 Feet 25 Feet 15 Feet Forevery extra 90 elbow reduce the allowable vent system length by 0 ft Two 45 elbow...

Page 5: ...lint creates a potential fire hazard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen inor over the exhaust duct Thiswill cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating...

Page 6: ...f the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Keep the duct us straight as possible for maximum airflow 4 Secure the duct to the exhaust pipe with the other clamp LEVELING AND STABILIZING YOUR DRYER Stand the dryer u...

Page 7: ...nformation 97GARAGE INSTALLATION IF ALLOWED BY LOCAL CODES Dryers installed in garages must be elevated 8 inches 46cm above the floor DRYER EXHAUST TO RIGHT LEFT OR BOTTOM CABINET WARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET BE SURE TO WEAR GLOVES i REPIOVE...

Page 8: ... BOTTOM OF CABINET Insert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape on the joint between the dryer internal duct and elbow as shown above CAUTION internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET SIDESAND BOTTOM EXHAUST PLATE KIT WEIM454 Connect standard metal...

Page 9: ...i r gido o de tipo papel de aluminio debe estar aprobado por UL e instalarse de acuerdo con los instrucciones de C6mo conectar la secadora a la ventilaci6n dom6sticd de los p6ginas 4 5 de este manual Los materiales de ventilaci6n flexibles a menudo se desploman se eplaston y atrapen pelusas Estas condiciones obstruyen la corriente de aire de la secadora e incrementan el riesgo de incendio No insta...

Page 10: ...uerda can la ilustraci6n del blaque terminal que correspondea su secadora Vuelvaa 4 conductores colocar el de cobre 10 Cable Cable tornillo verde AWG minima vivo Tornillo verde de conexi6n o kit decable a tierra aqui de suministro Tornillo Quite la cinta _ de conexi6n a tierra y desc tela Neutral Conserve blanco el tornillo verde de conexi6n vivo a tierra oporte Alivio de de alivio tensi6n de 3 4 ...

Page 11: ...xtremos hacia arriba no provistos Conexi6n de 3 cables NO usar en Canad6 NO usar en instalaciones en casas m6viles NO usar en casas nuevas NO usar en veh culos recreativos NO usar en 6reas donde los c6digos locales prohiben la connexi6n el6ctrica a tierra por el medio del cable neutral Desactive el interruptor de circuitos 30 amperios o quite el fusible del circuito de la secadora de la caja el6ct...

Page 12: ...s las condiciones indicadas a continuaci6n La Iongitud maxima del conducto para conductos r gidos de metal se indica en la siguiente tabla Cant de codas de 90 0 i 2 3 LONGITUDDESAUDA LONGITUD MAXllVlA RECOMENDADA Tipos de campana de salida Recomendado Metal Rigido 90 Pies 60 Pies 45 Pies 35 Pies Utilizar s61o en instalaciones de travecto corto 4 DIA _ _ 2 1 2 Metal Rigido 60 Pies 45 Pies 35 Pies 2...

Page 13: ... las pdginas 4 5 de este manual No instale la boca de salida dentro de una chimenea pared cielorraso ventilaci6n de gas espacio entre pisos ico bajo un piso con cerramiento o en cualquier otro espacio oculto de un edificio Laacumulaci6n de pelusas podr a provocar un riesgo potencial de incendio Nunca instale la boca de salida dentro de un conducto com0n con el sistema de salida de la cocina La com...

Page 14: ...apel de aluminio aprobado por UL SOLOen instalaciones en las que no pueden usarse conductos de metal rfgidos o flexibles semi rfgidos Y en las que puede mantenerse un didmetro de 4 a Io largode todo el conducto de transici6n EnCanade y los EstadosUnidos solamente deberc_n utilizarse los conductos de metal flexibles tipo papel de aluminio que cumplan con el Resumenpara conductos de transici6n para ...

Page 15: ...PARTE 32 80 o cuando dicha norma no sea aplicable con la NORMA NACIONAL ESTADOUNIDENSE PARA CASAS MOVILES ANSI NFPA NO501B La secadora DEBE tenet ventilaci6n al exterior con la terminaci6n bien sujeta a la estructura de la casa m6vil Vet la INFORMACION SABRE SALIDA secciones Sy 4 La ventilaci6n NO DEBE terminar debajo de una casa m6vil o prefabricada El material del conducto de ventilaci6n DEBE SE...

Page 16: ...montaje del conducto el coda primero a trav6s de la abertura lateral y conecte el coda al conducto interno de la secadora PRECAUCI6N Aseg6rese de no tirar o da6ar los cables el_ctricos ubicados dentro de la secadora cuando introduzca el conducto LA SALIDA PUEDE AGREGARSE A LOS LADOS DERECHO O IZOUIERDO X CINTA AISLANTE Aplique cinta aislante coma puede verse en lajunta entre el conducto interno de...