GE GEWADREW5001 Installation Instructions Manual Download Page 10

EXHAUSTING THE DRYER (cont.)

Installation Instructions

BEFORE YOU BEGIN

 

Remove and discard existing plastic or metal foil 

duct and replace with UL-listed duct.

 

Remove any lint from the wall exhaust opening.

Internal 

Duct 

Opening

Wall

Check that exhaust 

hood damper opens 

and closes freely.

STANDARD REAR EXHAUST

We recommend that you install your dryer before 

installing your washer. This will permit direct 

access for easier exhaust connection.

Slide the end of the exhaust duct on the back of the 

dryer and secure with duct tape or a duct clamp.

NOTE:

 We strongly recommend using rigid metal 

exhaust duct. However, if flexible ducting is used it 

must be UL-Listed metal, not plastic. 

 

For straight-line installation, connect the dryer 

exhaust to the wall, using duct tape or a duct 

clamp.

RECOMMENDED CONFIGURATION TO 

MINIMIZE EXHAUST BLOCKAGE

Using duct elbows will prevent duct kinking and 

collapsing.

Transition 

Ducting

10

EXHAUST SYSTEM CHECKLIST

HOOD OR WALL CAP

 

Terminate in a manner to prevent back drafts or entry 

of birds or other wildlife.

 

Termination should present minimal resistance to 

the exhaust airflow and should require little or no 

maintenance to prevent clogging.

 

Wall caps must be installed at least 12” above ground 

level or any other obstruction with the opening 

pointed down.

SEPARATION OF TURNS

 

For best performance, separate all turns by at least 

4 ft. of straight duct, including distance between last 

turn and dampened wall cap. 

SEALING OF JOINTS

 

All joints should be tight to avoid leaks. The male end 

of each section of duct must point away from the 

dryer.

 

Duct joints should be made air- and moisture-tight 

by wrapping the overlapped joints with duct tape or 

aluminum tape.

 

Do not assemble ductwork with any fasteners 

that extend into the duct. These fasteners can 

accumulate lint, creating a potential fire hazard.

 

Horizontal runs should slope down towards the 

outdoors 1/4” per foot.

 

Provide an access for inspection and cleaning of 

the exhaust system, especially at turns and joints. 

Exhaust system shall be inspected and cleaned at 

least once a year.

INSULATION

 

Ductwork that runs through an unheated area or is 

near air conditioning should be insulated to reduce 

condensation and lint buildup.

DUCT TAPE OR

DUCT CLAM

P

DUCT TAPE OR

DUCT CLAM

P

4" METAL DUCT CU

T

TO PROPER LENGTH

EXTERNAL DUCT

OPENING

Summary of Contents for GEWADREW5001

Page 1: ...ryer installation must be performed by a qualified installer Install the clothes dryer according to these instructions and local codes DO NOT install a clothes dryer with flexible plastic venting materials If flexible metal semi rigid or foil type duct is installed it must be UL listed and installed in accordance with the instructions found in Connecting the Dryer to House Vent later in this manua...

Page 2: ... hours a day or by phone at 800 626 2002 during normal business hours Part Number Accessory WE25X20060 Complete Kit hoses Y adapter washers included OR WE1M847 Long Hose and WE01X22395 Short Hose PM14X10056 Dryer door opening vent brush not included WX14X10007 LintEater Dryer rotary tube brush not included POWER CORDS GE strongly recommends the use of factory specified parts Select the power cord ...

Page 3: ...ust vent Provide an opening with a free area of at least 25 square inches for introduction of outside air into the dryer room See the sections for electrical connection information If the dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST be vented to the outdoors See the EXHAUSTING THE DRYER section Minimum clearance between dry...

Page 4: ...e the rubber flat washer is in place and attach the dryer s long inlet hose to one male end of the Y connector Tighten by hand until firmly seated 6 Ensure the rubber flat washer is in place and attach the other end of the dryer s long inlet hose to the fill valve connector at the bottom of the dryer back panel Tighten by hand until firmly seated 4 Installation Instructions CONNECTING INLET HOSES ...

Page 5: ... TERMINAL BLOCK Slip joint pliers Flat blade crewdriver Phillips screwdriver Level TOOLS YOU WILL NEED MATERIALS YOU WILL NEED 4 dia metal elbow 3 4 strain relief UL recognized 4 duct clamps 2 or 4 spring clamps 2 Safety glasses 4 dia metal duct recommended 4 dia UL listed flexible metal duct if needed Gloves Exhaust hood Duct tape Dryer power cord kit not provided with dryer UL rated 120 240V 30A...

Page 6: ...fire or electrical shock GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet...

Page 7: ...e electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located at the lower back 4 Remove and discard ground strap Keep the green ground screw for Step 7 5 Install 3 4 in UL recognized strain relief to power cord entry hole Bring power cord through strain relief 6 Connect power cord as follows A Connect the 2 hot lines to the outer screws of t...

Page 8: ...tion duct maximizing drying performance Avoid resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the dryer to the home exhaust vent using flexible metal foil type transition duct UL LISTED universal flexible dryer transition duct GE parts PM8X73 or WX8X73 may be used ONLY in installations where rigid metal or...

Page 9: ... will be treated like one 90 elbow For every additional 90 elbow reduce the allowable vent system length by 10 feet When calculating the total vent system length you must add all the straight portions and elbows of the system including the transition duct EXHAUST LENGTH 9 DO NOT bend or collapse ducting Use elbows if turns are necessary DO NOT use excessive exhaust length Cut duct as short as poss...

Page 10: ...uld present minimal resistance to the exhaust airflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and dampened wall cap SEALING OF JOIN...

Page 11: ...w to the dryer internal duct Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct TAB LOCATION Fire Hazard WARNING Close the back opening with cover plate Kit WE1M454 Disconnect dryer from electrical supply Wear gloves and arm guards Failure to do so may result in fire electrical shock or lacerations Through the rear opening locate the tab in the middle of th...

Page 12: ...afety hazard 12 DUCT TAPE ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET Insert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape as shown on the joint between the dryer internal duct and the elbow and also the joint between the elbow and the bottom duct Internal duct joints must be secured with tape otherwise they may separate and cause a safety haza...

Page 13: ...pped putty knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING THE DOOR SOLID DOOR MODELS 1 Open the door approximately 130 degrees With a putty knife remove the 4 plastic caps located along the left side of the front panel and set them aside 2 Remove the bottom screw from each ...

Page 14: ...ed in step 3 into the lower left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the original setup follow these instructions swapping left and right When you finish Plug the dryer back into its electrical outlet Door Hang door and tighten screws Plastic Cap 4 Right side of front pane...

Page 15: ...n the left and 2 on the right 3 Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 4 Remove both the blind plate and the strike plate and install them in the opposite positions 5 Remove the 4 door hinge screws 6 inside screws and 2 pocket screws Lift the inner door upwards using a...

Page 16: ...or Rotate outer door 180 Inside screw Inside screws Pocket screws Inside screw Door hinge screws Inside screw Inside screw B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 8 Mount the assembled door on the 2 upper left side hinge screws installed in step 2 Move the hinge screws loosened in step 2 into the lower left side screw holes and firmly tighten all 4 screws 9 Install the 4 plastic caps rem...

Reviews: