Indoor Unit Installation

D river

Torque wrench

(17mm, 22mm, 26mm)

Nipper

Reame r

Hacksaw

P ipe cutter

G as leak age detector or
soap-and-water solution

Hole core drill

F laring tool

S panner(17,19 and 26mm)

K nife

Measu ring tape

Necessary

T

ools for Installation

Power Source

T he electrical power outlet should be located sufficiently clos

e

to the indoor unit, such that the cord-set and plug are not plac

ed

Do NO T extend the power cord for any reason. If the electrica

l

T he electrical power outlet should have sufficient capacity for

the

A exclusive brance circuit sh ould be used.

rated input current/power marked on the rating plate.

Selection of the Installation Location

Install on the wall that is sufficiently strong and robust

to support the weight of the Indoor unit.

T he installation location should be away from sources

of heat and humidity.

Locate where the connection piping& electrical cable
can be easily connected to the outdoor unit.

Locat e where the drain house outlet will not cause a

Locate where the cooled/heated air can be spread entirely

Locat e clos e to an accessible power outlet.

Locate more than 1m away from televisions, wireless devices

and fluoresecent lamps.

If the remote control is fixed to a wall, locate it in a  location

where the signal is not affected by fluorescent light starting

devices.

T he distance between the indoor unit and the floor should be more than 2m.

T hese indoor unit models are designed exclusively for use with HF C refrigerant R 410A .

more than
10cm

more than 15 cm

more than 10cm

A rrange ment of piping
directions

Rea r left

Le ft

Rear
right

R ight

B elow

Attention must be paid to

the rising up of drain hose

Please be subject to the actual product purchased,the above picture is just for your reference.

Remot e controlle r (1)

Mounting plate (1)

Drain hose (1)

Ø 4X 25 S crew (4)

P las tic cap (4)

Accessory Parts 

FOR  09K 12K

FOR 18K

Selection of Pipe

11

Drawing for the installation of indoor units

disturbance on the outside of the wall.

around the room ( avoid corners of rooms) .

under strain.

power outlet is too far away, it should be relocated by a quali

fied

electrician in accordance with local codes and regulations.
T he air conditioner should always be plugged into itsown

individual electrical outlet having a voltage rating that matche

s

the rating plate.

Air purifying filter((1)

RISK OF PERSONAL INJURY. 

Do not locate the Indoor Unit in a location where the
airflow is likely to be channeled directly at people or

animals.

Risk of electric shock. Can cause injury or death.

Ø 4X 12 S crew (2)

24K

Summary of Contents for GES-NIG25IN

Page 1: ...UBLE SHOOTING 15 Write the model and serial numbers here Model _________________________ Serial ____________________________ 1 SAFETY INFORMATION SPECIFICATIONS 16 This appliance is filled with R32 GES NJGW25IN 1 GES NJGB35IN 1 GES NJGW35IN 1 GES NJGB50IN GES NJGW50IN GES NMG25IN GES NMG35IN GES NMG50IN GES NMG70IN GES NIG25IN GES NIG35IN GES NM25IN M GES NM35IN M ...

Page 2: ...hazardous situation which if not avoided could result in death or serious injury Indicates a hazardous situation which if not avoided could result in minor or moderate injury SAFETY INFORMATION WARNING DANGER CAUTION WARNING qualified persons in order to avoid a hazard A Turn OFF and unplug your air conditioner before performing any user maintenance or cleaning This appliance can be used by childr...

Page 3: ...STRUCTIONS BEFORE USING WARNING RISK OF FIRE Could cause serious injury or death DO NOT use an adaptor plug with this Air Conditioner DO NOT use surge protectors or multi outlet adaptors with this Air Conditioner USE OF EXTENSION CORDS READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY SAVE THESE INSTRUCTIONS WARNING Ensure that any connecting cables that are used to connect the indoor and out door...

Page 4: ... Used to set HEAT operation Used to set COOL operation QUIET button n o i t c n u f h c a e f o y a l p s i D status Operation mode display TEMP display Humidity display FAN SPEED display SWING display Swing up down display swing left right display TIMER ON display TIMER OFF display ON OFF button button button pressed temp setting increases 1ºC pressed temp setting decreases 1 ºC Signal sending di...

Page 5: ...GES NJGB25IN 1 GES NJGW25IN GES NJGB35IN 1 1 GES NJGW35IN 1 GES NJGB50IN GES NJGW50IN GES NMG25IN GES NMG35IN GES NMG50IN GES NMG70IN GES NM25IN M GES NM35IN M ...

Page 6: ...e is needed for rest or reading For each press is displayed Air conditioner starts QUIET function operation In QUIET operation mode fan speed automatically takes low speed of AUTO fan mode Press QUIET button again disappears the operation stops QUIET Unit start Select operation mode Press the COOL button on the remote control Press the HEAT button on the remote control Press the DRY button on the ...

Page 7: ...essed temp setting decreases 1 ºC 1 2 1 POWER POWER Operation Press POWER Operation Powerful function available in heating and cooling mode after unit turn on SMART HEALTH AIRFLOW POWER LIGHT CODE DRY FAN MODE SLEEP LOCK TIMER CONFIRM CANCEL SWING QUIET COOL HEAT TEMP TEMP FAN FAN SPEED AUTO AUTO button TEMP TEMP FAN LOW MED HI AUTO QUIET COOL HEAT TEMP TEMP FAN FAN SPEED AUTO AUTO ...

Page 8: ...umidity a phenomenon falling drips of water occurs at the outlet grille 5 Select the appropriate fan direction according to the actual conditions 7 SMART HEALTH AIRFLOW POWER LIGHT CODE DRY FAN MODE SLEEP LOCK TIMER CONFIRM CANCEL SWING QUIET COOL HEAT TEMP TEMP FAN FAN SPEED FAN MODE Operation Fan mode default low fan speed fan mode1 the setting temperature will not display the temperature of ind...

Page 9: ...t occur at air outlet if all vertical louvers are adjusted to left or right position for a long time in COOL or DRY mode otherwise condensate water might occur 1 2 HEAT SMART Initial state Initial state For each press of button remote controller displays as follows remote controller 8 GES NIG25 35 IN range without this function better air circulation SMART HEALTH AIRFLOW POWER LIGHT CODE DRY FAN M...

Page 10: ...crease by 2 ºC further After more another 3 hours temp rises by 1 ºC further The unit will run for further 3 In SMART mode The unit operates in corresponding sleep mode which adapted to the automatically selected operation mode 4 When quiet sleeping function is set to 8 hours the quiet sleeping time can not be adjusted When TIMER function is set the quiet sleeping function can t be set up After th...

Page 11: ...IRM CANCEL SWING QUIET COOL HEAT TEMP TEMP FAN FAN SPEED AUTO AUTO AUTO ON OF F Operation Use this operation only when the remote controller is defective or lost and with function of emergency running air conditoner can run automatically for a while When the emergency operation switch is pressed the Pi sound is heard once which means the start of this operation emergency operation starts the unit ...

Page 12: ...luoresecent lamps If the remote control is fixed to a wall locate it in a location where the signal is not affected by fluorescent light starting devices The distance between the indoor unit and the floor should be morethan 2m These indoor unit models are designed exclusively for use with HFC refrigerant R 410A more than 10cm more than 15cm more than 10cm Arrangement of piping directions Rea r lef...

Page 13: ...he plug pass through Preparation of piping and conne cting wiring 4 1 Cut the connecting wirings 1 5m longer than the pipe length Cut the pipes a little longer than measured distance Measure the distance between the indoor and the outdoor unit Use the accessory piping kit or the pipes Cut the pipes and cables Turn the pipe end down to avoid the metal powder entering the pipe 2 Remove the burrs 3 I...

Page 14: ...he warm area to prevent condensation Problems with the piping may lead to water leaks and interior property damage 2 Do not install the drain pipe as follows It is raised after exiting the wall The end is immersed in water It has raised sections near the ground Too close to the ground The end of the hose is near to drains with bad odours 3 Pour water in the drain pan of the indoor unit to confirm ...

Page 15: ...he water out of the cloth before wiping then wipe off the detergent completel y Air Filter cleaning Open the inletgrille by pulling it upward R emove the filter C lean the filter Attach the filter C lose the inlet grille Push up the filter s center tab slightly until it is from the stopper and remove the filter downward Use a vacuum cleaner to remove dust or wash the filter with water After washin...

Page 16: ...lownout Is the air filter dirty Are there any obstacles before Is temperature set correctly Are there some doors or Is there any direct sunlight through the window during the Are there too much heat sources or too many people in the room In dry mode fan speed can t be changed In DRY mode when room temperature setting 2 o C unit will run regardless of FAN setting during cooling operation cooling op...

Page 17: ...ld for charging Important information regarding the In accordance with the directive of the European parliament herewith we inform the consumer about the dis posal requirements of the electrical and electronic products conditioning system treatment of the refrigerant of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation Air condit...

Reviews: