37

38

GEP30-L-10

39000

800

200~650
270~650

180
370

30 or 26

*1

37.5 or 33

*1

0
5
2

 

30000
30000
30000
30000
30000
30000

220, 3L/N/PE or 3L/PE

176~242

50/60

47.5~51.5/57~61.8

80.0

300

50

78.7

<3%

98.0%
97.7%

GEP35-L-10

45500

800

200~650
270~650

180
370

30 or 26

*1

37.5 or 33

*1

0
6
2

 

35000
35000
35000
35000
35000
35000

220, 3L/N/PE or 3L/PE

176~242

50/60

47.5~51.5/57~61.8

96.0

300

50

91.9

<3%

98.0%
97.7%

Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated

Type II (Type I Optional)

Type II

Optional
Optional
Optional
Optional

30~60 (60 °C for outdoor unconditioned with solar effects.)

0~100%

3000

Smart Fan Cooling

LED, LCD (Optional), WLAN+APP

RS485, WiFi, USB, PLC (Optional)

*5

Modbus-RTU

 SunSpec compliant

55

 500*660*220

65

Non-isolated

GEP60-10

90000

1100

200~950
510~860

180
600

30 or 26

*1

37.5 or 33

*1

0
6
2

 

60000
60000

66000

*2

66000

*3

60000
60000

400

*4

, 3L/N/PE or 3L/PE

320~460

50/60

47.5~51.5/57~61.8

96.0

300

50

86.6

<3%

98.3%
98.0%

GEP50-10

75000

1100

200~950
510~860

180
600

30 or 26

*1

37.5 or 33

*1

0
5
2

 

50000
50000

55000

*2

55000

*3

50000
50000

400

*4

, 3L/N/PE or 3L/PE

320~460

50/60

47.5~51.5/57~61.8

80.0

300

50

72.2

<3%

98.3%
98.0%

~1 (Adjustable from 0.8 leading to 0.8 lagging)

Technical Data

Input (DC

Max. Input Power (W)
Max. Input Voltage (V)
MPPT Operating Voltage Range (V)
MPPT Voltage Range at Nominal Power (V)
Start-up Voltage (V)
Nominal Input Voltage (V)
Max. Input Current per MPPT (A)
Max. Short Circuit Current per MPPT (A)
Max. Backfeed Current to The Array (A)
Number of MPP Trackers
Number of Strings per MPPT

Output (AC

Nominal Output Power (W)
Nominal Output Apparent Power (VA)
Max. AC Active Power (W)
Max. AC Apparent Power (VA)
Nominal Power at 40

 (W)

Max Power at 40

 (Including AC Overload) (W)

Nominal Output Voltage (V)
Output Voltage Range (V)
Nominal Output Frequency (Hz)
AC Grid Frequency Range (Hz)
Max. Output Current (A)
Max. Output Fault Current (Peak and Duration) (A/ms)
Inrush Current (Peak and Duration) (A/us)
Nominal Output Current (A)
Power Factor
Max. Total Harmonic Distortion

Efficiency

Max. Efficiency
Europen Efficiency

Protection

PV String Current Monitoring
Internal Humidity Monitoring
PV Insulation Resistance Detection
Residual Current Monitoring
PV Reverse Polarity Protection
Anti-islanding Protection
AC Overcurrent Protection
AC Short Circuit Protection
AC Overvoltage Protection
DC Switch
DC Surge Protection
AC Surge Protection
AFCI
Remote Shutdown
PID Recovery

General Data

Operating Temperature Range (

)

Relative Humidity
Max. Operating Altitude (m

Cooling Method 
Display
Communication
Communication protocols
Weight (kg)
Dimension W×H×D (mm

Noise Emission (dB)
Topology

GEP30-L-10

GEP35-L-10

GEP60-10

GEP50-10

Technical Data

General Data

Self-consumption at Night (W)
Ingress Protection Rating
Anti-corrosion Class
DC Connector
AC Connector
Environmental Category
Pollution Degree
Overvoltage Category
Protective Class
The Decisive Voltage Class (DVC)
Country of Manufacture

1

IP65

C5

MC4(Max.6mm²

OT/DT Terminal (Max.25mm²)

4K4H

III

DC II / AC III

I

PV:C, AC:C, com:A

China

*1

Subject to the nameplate. 

*2: For Brazil Max. AC Active Power GEP50-10 is 50000W, GEP60-10 is 60000W.

*3: For Brazil Max. AC Apparent Power GEP50-10 is 50000W, GEP60-10 is 60000W.

*4: For Brazil Nominal Output Voltage is 380V, 3L/N/PE or 3L/PE

*5 For Brazil Communication is RS485,WiFi,USB,PLC(Optional)

Summary of Contents for GEP12-L-10

Page 1: ...UAL Global Sales Service Network GE is a registered trademark of General Electric Company and is used under license by GoodWe Technologies Co Ltd No 90 Zijin Rd New District Suzhou 215011 China www ge...

Page 2: ...7 5 System Operation 21 5 1 LCD Panel And LED 21 5 2 User Interface Introduction 22 5 3 System Configuration 25 5 4 Precaution For Initial Startup 30 5 5 Setting Inverter Parameters via App 31 5 6 Mon...

Page 3: ...work All detailed work related safety warnings and notes will be specified at the critical points in corresponding chapter All installation and electrical work must only be performed by qualified per...

Page 4: ...ons which will lead to potential injury to people and damage to inverters Static electricity may damage electronic components Appropriate method must be adopted to prevent such damage to the inverter...

Page 5: ...ter provides standard interface RS485 WIFI for communication Inverters also provide running recode data display parameter configuration via LCD panel For the main block diagram please refer to chapter...

Page 6: ...ommunication Terminal Grounding Screw Expansion Bolt Safe Screw Connecting Terminal Grounding AC Cover OT Terminal Insulation Sleeve WiFi Module WiFi communication Or without LCD Quick Installation In...

Page 7: ...values The Upward part The downward part The front part Both sides Interval 200mm 500mm 500mm 600mm 1200mm 500mm 1200mm 600mm 600mm 500mm 300mm The Upward part The downward part The front part Both si...

Page 8: ...low these steps to connect the utility and inverter 7 If the diameter of the cable does not match the terminal or if the cable is aluminum cable please contact after sales service Two mounting holes i...

Page 9: ...et of a suitable length with a wire stripper Output Current 31 5A 40A 54 5A 40A 43 3A 48A 53 3A 80A 96A 80A 96A Inverter Model GEP12 L 10 GEP15 L 10 GEP20 L 10 GEP25 10 GEP29 9 10 GEP30 10 GEP36 10 GE...

Page 10: ...not met The GEP series has three PV input area PV1 input PV2 input PV3 input each with MPPT tracker therefore the three PV input can be different with each other including different type of modules di...

Page 11: ...zlogger Pro manual Remote shutdown is only for European installations in compliance with European safety requirements A remote shutdown device is not provided by manufacturer DRED should be connected...

Page 12: ...ion This function is only applicable for WiFi model for specific configurations please refer to WiFi LAN Configuration Instruction in the attachment and you can also refer to the description of Demo V...

Page 13: ...ive On Fault occurred OFF No fault Status Indicator Green green green red light respectively corresponds to 5 2 User Interface Introduction Communication information icon GPRS and WiFi show the signal...

Page 14: ...Fi 22 93 3kWH 4 E TOTAL E DAY 01 01 2020 00 00 00 CARBON Fault Utility Loss 0 0kWH Basic Advanced WiFi 22 105 3kWH 4 E TOTAL E DAY 01 01 2020 00 00 00 Fault WiFi Con guration 22 Basic Advanced 01 01 2...

Page 15: ...0 00 Fault Country Code Holland Northlreland ChinaHigher France 50Hz France 60Hz WiFi 22 01 01 2020 00 00 00 Fault Language WiFi 22 01 01 2020 00 00 00 Fault Data Time WiFi 22 01 01 2020 00 00 00 Faul...

Page 16: ...i 22 01 01 2020 00 00 00 Normal Adv Settings HVRT Grid Type Password Factory Data Reset WiFi 22 01 01 2020 00 00 00 Normal Adv Settings HVRT Grid Type Password Factory Data Reset WiFi 22 01 01 2020 00...

Page 17: ...0 6 0 4 0 2 0 4 6 8 10 12 14 16 18 20 Month Year Basic Advanced 01 01 2020 00 00 00 Fault WiFi Con guration 22 Basic Advanced 01 01 2020 00 00 00 Normal WiFi Con guration 22 01 01 2020 00 00 00 Norma...

Page 18: ...local service office 1 Disconnect the DC switch take off DC connector check PV string voltage check if it exceeds the input voltage in inverter specification 2 If it does please reconfigurate PV panel...

Page 19: ...ber of MPP Trackers Number of Strings per MPPT Output AC Nominal Output Power W Nominal Output Apparent Power VA Max AC Active Power W Max AC Apparent Power VA Nominal Power at 40 W Max Power at 40 In...

Page 20: ...rent A Max Output Fault Current Peak and Duration A ms Inrush Current Peak and Duration A us Nominal Output Current A Power Factor Max Total Harmonic Distortion Efficiency Max Efficiency Europen Effic...

Page 21: ...T Output AC Nominal Output Power W Nominal Output Apparent Power VA Max AC Active Power W Max AC Apparent Power VA Nominal Power at 40 W Max Power at 40 Including AC Overload W Nominal Output Voltage...

Page 22: ...pment in an industrial installation Category IV applies to equipment permanently connected at the origin of an installation upstream of the main distribution board For example electricity meters prima...

Page 23: ...PV plant Caution Before maintenance please disconnect the AC breaker rst and then disconnect DC breaker Wait 5 minutes until the residual voltage has been released 8 1 Clearing The Fan Series inverte...