GE GEMX50-W1 Installation Manual Download Page 3

3

To power 

supply 

Red (+)

Red (+)

White (-)

Black or blue (-)

Connect the red wire (+) of the LED strip to the red 

wire (+) of the power supply. Connect the white 

wire (-) of the LED strip to the black or blue wire (-) 

of the power supply.
NOTE:

  All electrical connections should be made 

within the letter.

4

Power 

Supply

To Tetra LED System

Red (+)

Black or blue (-)

Run a wire from the Power Supply to each channel 

letter and connect to the first LED module on the 

strip. 
Must be used with Tetra® 12 Volt Power Supplies.

Retrofit Instructions

1.   (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the building.  Ensure   

 

that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have  

 

 

a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).   

2.   (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and associated    

 

 

transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes.  

 NOTE:

 Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.

3.   (Existing Signs Only)  If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable local, state, or  

 

 

country electrical codes; a new disconnect switch must be installed.

4.   (Existing Signs Only) Make sure the removal of lighting equipment does not compromise the integrity of the sign body (i.e. water intrusion). Fill in    

 

all holes 0.5 in. (13 mm) or smaller with the appropriate amount of rated caulk or sealant. For holes greater than 0.5 in. (13 mm), use an aluminum   

 

or zinc coated steel patch with rivets and sealant.

5.   (Existing Signs Only) A clean and dry mounting surface ensures optimum adhesion if the self-adhesive method of mounting is chosen.  Follow  

 

 

the manufacturer’s directions when using a non-oil based solvent, such as rubbing alcohol to clean the surface area where you intend to mount    

 

the module.  Before installing, ensure the surface is dry.

6.   Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
7.   A Tetra

®

 12VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Using the Maximum Loading chart below, determine the    

 

number of Tetra

®

 Class 2 Power Supplies required to power the number of LED modules required to illuminate the sign, so as not to overload  

 

 

the Tetra

®

 Class 2 Power Supply chosen.

8.   Follow the instructions above to properly mount the LED modules. 
9.   Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
10. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions found in the  

 

power supply installation guide.

11. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable  local, state, and country electrical codes.

Cap wires

Connect LED strips using in-line (IDC) connectors or 

twist-on wire connectors.

1

2

Red (+)

White (-)

Electrical Connections

Must cap all exposed wires with appropriate wire 

connectors.

Summary of Contents for GEMX50-W1

Page 1: ...s equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This Class A RFLD complies with the Canadian standard ICES 003 Ce DEFR de la classe A est conforme à la NMB 003 du Canada RISK OF ELECTRIC SHOCK Turn power off before inspection installation or removal Properly ground Tetra power supply en...

Page 2: ... rivets or silicone 4 5 6 Clean and remove all debris from the inside of the channel letter before you begin 1 NOTE For halo lit applications LED modules should be mounted on UL recognized clear acrylic or polycarbonate The light output from the LED system should be directed back into the sign enclosure This will allow for uniform backlighting of the sign and will provide simple mounting UL approv...

Page 3: ...equipment does not compromise the integrity of the sign body i e water intrusion Fill in all holes 0 5 in 13 mm or smaller with the appropriate amount of rated caulk or sealant For holes greater than 0 5 in 13 mm use an aluminum or zinc coated steel patch with rivets and sealant 5 Existing Signs Only A clean and dry mounting surface ensures optimum adhesion if the self adhesive method of mounting ...

Page 4: ...modules 53ft 16 15m 106 modules 53ft 16 15m per output channel 318 modules 159ft 48 46m per power supply GEMXHRD W1 12VDC 47mA module 0 564W module 36 modules 18ft 5 48m 100 modules 50ft 15 24m 100 modules 50ft 15 24m per output channel 300 modules 150ft 45 72m per power supply Troubleshooting Symptom Solution All letters are OFF Check AC input connection and or check circuit breaker Check wire co...

Reviews: