10 Technical Parameters
User Manual V1.0-2023-10-30
83
Technical parameters
GEH10-3U-20
GEH12-3U-20
GEH15-3U-20
Self-consumption at Night (W)*
7
<15
<15
<15
Ingress Protection Rating
IP66
IP66
IP66
DC Connector
MC4 (4~6mm
2
)
MC4 (4~6mm
2
)
MC4 (4~6mm
2
)
AC Connector
Feed-Through
Terminal Blocks
UW10
Feed-Through
Terminal Blocks
UW10
Feed-Through
Terminal Blocks
UW10
Environmental Category
4K4H
4K4H
4K4H
Pollution Degree
III
III
III
Overvoltage Category
DC II / AC III
DC II/AC III
DC II/AC III
Protective Class
I
I
I
Storage Temperature (
℃
)
-40~+85
-40~+85
-40~+85
The Decisive Voltage Class (DVC)
Battery: C
PV: C
AC: C
Com: A
Battery: C
PV: C
PV: C
Com: A
Battery: C
PV: C
AC: C
Com: A
Mounting Method
Wall Mounted
Wall Mounted
Wall Mounted
Active Anti-islanding Method*
8
AFDPF + AQDPF
AFDPF + AQDPF
AFDPF + AQDPF
Type of Electrical Supply System
Three phase Grid
Three phase Grid
Three phase Grid
Country of Manufacture
China
China
China
Certification*
9
Grid Standards
VDE-AR-N 4105,EN50549-1
Safety Regulation
IEC62619-1/-2
EMC
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
*1: Max. Input Power, not continuous for 1.6*normal power.
*2: For 1000V system, Maximum operating voltage is 950V.
*3: According to the local grid regulation.
*4: Output Voltage Range: phase voltage.
*5: the Max.AC Current Output to on-grid load is 13A, 17.4A, 21.7A, 21.7A, 21.7A, 21.7A
separately.
*6: Can be reached only if PV and battery power is enough.
*7: No Back-up Output.
*8: AFDPF: Active Frequency Drift with Positive Feedback, AQDPF: Active Q Drift with Positive
Feedback.
*9: Not all certifications & standards listed, check the official website for details.