Anode Rod

Anode rods are designed and installed to protect and 

H[WHQGWKHOLIHRIUHVLGHQWLDOZDWHUVWRUDJHWDQNV

The anode rod must be removed from the water heater’s 
tank and inspected annually, and replaced when more than 

´FPRIFRUHZLUHLVH[SRVHGDWHLWKHUHQGRIWKH

rod.* Note: Artificially softened water will cause the anode 
rod to consume more rapidly.

Due to shock hazard and to prevent accidental water leaks, 
this inspection should be done by a qualified servicer or 
plumber, and requires that the electric power and cold water 
supply be turned off before servicing the anode rod.

NOTICE: Do not remove the anode rod from the water 

KHDWHU¶VWDQNH[FHSWIRULQVSHFWLRQDQGRUUHSODFHPHQWDV

operation with the anode rod removed will shorten the life of 
the glass-lined tank and will void warranty coverage.

Some areas have water conditions that may cause an 
odor to develop in the water heater. Aluminum-Zinc alloy 
replacement rods are available to address the condition.

*

NOTE: 

Failure to replace the anode rod when consumed 

risks voiding the warranty for the tank. Warranty coverage 
for all other components remains intact, and is unaffected 
by this maintenance requirement. The replacement anode 
rod, and the inspection for consumption are not covered by 
warranty.

Additional information for models with an anode 
depletion sensing feature (Anode button on the 
control):

When the depletion-sensing anode rod nears end of life, 
the red light above the ANODE button will illuminate and 
the control will beep and display F16. When this occurs, the 
anode rod must be inspected and replaced if the core wire 

DWWKHWRSRIWKHDQRGHURGLVH[SRVHGRULIWKHOHQJWKRIWKH
DQRGHURGLVOHVVWKDQ´FP,WLVUHFRPPHQGHGWR

replace the anode rod as soon as possible to ensure that 
the tank will continue to be protected from corrosion. Call 
GE Appliances Service to order or to replace the anode rod. 
(See page 12 for instructions to change the anode rod.) GE 
Appliances Service: 888.4GE.HEWH (888.443.4394).

Press the ANODE button once to silence the alarm. Once 
replaced, reset the alarm by pressing and holding the 
ANODE button for 10 seconds until the control beeps and 
the LED above the button turns off. 

If an Aluminum-Zinc anode rod is installed to address a 
water odor condition, the anode depletion sensing feature 
must be disabled. If disabled, annual inspections of the 
anode rod are required since the water heater will no longer 
be capable of alerting for a depleted anode rod. 

To disable the feature: 

1.    Upon power-up following an Aluminum-Zinc anode rod 

installation, the control will sound an alarm and F17 will 
display. Press the ANODE button to quiet the alarm. 

2.    

3UHVVWKH$12'(EXWWRQWLPHV³2II´RU³2Q´ZLOO

display confirming that the feature has been disabled/ 
enabled. 

To enable the feature if a new anode depletion sensing 
anode rod is installed, follow Step 2 above. 

Note: If the display is blank, press any button to wake the 
control before entering a button combination. 

NOTE: 

If the water heater has been installed with a 

device that periodically cuts power to the water heater, the 
accuracy of the anode rod depletion sensing feature may 
become compromised and anode rod inspection every 2-3 
years is required.

If the water heater will be inactive for a long period of time 
and the water heater cannot be drained, it is recommended 
to leave the power turned on with the water heater in 
vacation mode to ensure that the feature will continue to 
operate properly while still conserving energy.

NOTE: Refer to the Hydrogen Gas Caution in the 
Operating Instructions (see page 3).

Care and Cleaning

Routine Preventative Maintenance

Summary of Contents for GEH50DFEJS

Page 1: ...any Manufactured under trademark license OWNER S MANUAL WATER HEATERS GeoSpring TM Hybrid Electric Residential 49 50300 2 10 16 GEA GEH50DEEJS GEH50DFEJS GEH80DEEJS GEH80DFEJS SAFETY INFORMATION 3 OPE...

Page 2: ...nto every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need...

Page 3: ...this or any other appliance Keep rags and other combustibles away FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that residential water heaters must be braced anchored or strapp...

Page 4: ...ew setting Note To change between F and C press and hold MODE WATER TEMPERATURE ADJUSTMENT Safety energy conservation and hot water capacity are factors to be considered when selecting the water tempe...

Page 5: ...mperature setting strongly impacts the amount of usable hot water available for showers and baths QHUJ FRQVXPSWLRQ VDYLQJV DQG HI FLHQF WHVWLQJ of water heaters including the GeoSpring is performed ac...

Page 6: ...EAT PUMP HYBRID HIGH DEMAND BOOST ELECTRIC STANDARD VACATION F C DAYS GeoSpring Hold for F C Hold to Reset Hold to Override PS Power Saver Anode Enter Filter Power Mode Saver on some models Displaying...

Page 7: ...mode and High Demand Boost mode is that in High Demand Boost mode the heating resistive elements are activated sooner than in Hybrid mode Electric Standard Mode This mode uses only the upper and lower...

Page 8: ...HR6SULQJ ZDWHU KHDWHU 7R FRQQHFW your water heater to the internet through your home s wireless internet router plug the ConnectPlus cable into the communication port on the front of your GeoSpring a...

Page 9: ...ound OHYHO LQFUHDVHV H FHVVLYHO WKH HOHFWULF KHDWLQJ HOHPHQW PD UHTXLUH FOHDQLQJ RQWDFW D TXDOL HG LQVWDOOHU RU plumber for inspection Draining and Flushing the Water Heater CAUTION Risk of Shock Shut...

Page 10: ...reset it will continue in Electric Standard mode to finish the cycle then automatically revert to the previously selected mode IMPORTANT Filter must be cleaned when the alarm is displayed A dirty filt...

Page 11: ...P W LV UHFRPPHQGHG WR replace the anode rod as soon as possible to ensure that the tank will continue to be protected from corrosion Call GE Appliances Service to order or to replace the anode rod See...

Page 12: ...en to 50 5 ft lbs of torque Plug in the wire for the anode rod some models If an Aluminum Zinc or other non sensing anode rod is installed the anode depletion sensing feature must be disabled and the...

Page 13: ...up to the installation location Moving the water heater or other appliances to provide service to the water heater is not covered under warranty NOTE The heat pump operating range is 35 F to 120 F 2...

Page 14: ...HUPDO H SDQVLRQ WKH UDSLG SUHVVXUH LQFUHDVH can cause the relief valve to operate releasing water during each heating cycle potentially causing premature failure to the valve or even the water heater...

Page 15: ...pressure rating of the relief valve must not exceed 150 PSI 1 03 kPa the maximum working pressure of the water heater as marked on the rating plate A new combination temperature and pressure relief v...

Page 16: ...r s warranty does not cover any damage or defect caused by installation attachment or use of any type of energy saving or other unapproved devices other than those authorized by the manufacturer into...

Page 17: ...displays 120 F 49 C Hybrid mode Assist user in how to adjust temperature and PRGHV VHH DWHU 7HPSHUDWXUH GMXVWPHQW VHFWLRQ RQ SDJH WHAT TO EXPECT FOR NORMAL STARTUP IN HYBRID MODE After the unit has be...

Page 18: ...n I hear the unit run Q WKH PRVW HQHUJ HI FLHQW PRGHV HDW 3XPS EULG DQG High Demand Boost the method used to heat the water uses a fan that can be heard while running Q The heat pump is not running it...

Page 19: ...QLW LV DZD IURP WKH ZDOO DQG KDV FOHDU DQFH DERYH WKH DLU OWHU Room is too small or too cool slowing heating performance Smaller rooms can lead to cooler room temperatures due to the heat pump cooling...

Page 20: ...bAdlinE Unit is not receiving 240VAC as intended Turn off power to water heater generally at the breaker panel Then read Electrical Connections section of the Installation Instructions see page 16 Th...

Page 21: ...or Evap outlet temperature Failure Call service F7 T4 Sensor Compressor outlet Failure Call service F8 T5 Sensor ambient temperature Failure Call service F9 Lower Heating Element Failure Call service...

Page 22: ...family use labor will not be covered under warranty and the parts warranty is reduced to 1 year from the date of purchase 7KLV ZDUUDQW LV H WHQGHG WR WKH RULJLQDO SXUFKDVHU DQG DQ VXFFHHGLQJ RZQHU IRU...