Specifications

Performance Data

Min

Typical

Max

Input Voltage (VDC)

23

24

25

Input Current (A) 

-

-

4

Output Voltage (VDC)

2.1

-

 2.8

Output Current (ADC)

 - 

5.0

Output Power (W) 

-

 56

Environmental Operating Temperature Range 

-40°C 

+25°C 

+55°C*

Environmental Humidity (non-condensing) 

0% 

95%

Environmental Storage Temperature Range 

-40°C

 - 

+85°C

Dimensions

9.5 in. x 1.7 in. x 1.2 in. (241 mm x 43.2 mm x 30.5 mm)

* Maximum case temperature is 85°C

NOTE: 

Power off the power supply when setting the dip switches.

NOTE: 

Do not connect outputs in series or parallel.

NOTE: 

When installing power supply, connect to the appropriate sized building breaker or disconnect device for line and neutral

connections, in accordance with local, state or country regulations.

NOTE: 

The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code 

(NEC) Article 600.

SIGNXXX-R071514

GE Lighting Solutions •  1-888-MY-GE-LED •  www.gelighting.com

1 - 8 8 8 - 6 9 - 4 3 - 5 3 3

GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company. 

© 2014 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

This product is intended to be used as a lamp control gear that is installed after the mains control switch.

Conforms to the following standards:

GE Lighting 1975 Noble Rd, Cleveland, OH 44112

Summary of Contents for GECLPS3-2

Page 1: ...e in dry and damp locations The grounding and bonding of the LED Driver shall be done in accordance with National Electric Code NEC Article 600 Follow all National Electric Codes NEC and local codes These products are only suitable for connection to a circuit from a Class 2 power source These products have not been evaluated for use when connected to a power source that does not comply with Class ...

Page 2: ...ied personnel in accordance with applicable local state and country electrical codes Make sure the removal of lighting equipment does not compromise the integrity of the sign body i e water intrusion Fill in all holes 0 5 in 13 mm or smaller with the appropriate amount of rated caulk or sealant For holes greater than 0 5 in 13 mm use an aluminum or zinc coated steel patch with rivets and sealant G...

Page 3: ...D per foot Tetra Strip If you change the dipswitch setting and flip 2 switch to the ON position the power supply can support up to 80 ft 24 4m of Tetra Strip The footage guidelines vary based on the type of Tetra Strip being used The charts below provide the footage requirements for each Tetra Strip type CAUTION Avoid setting the dip switch to the ON position with any setting not listed in the cha...

Page 4: ...nections in accordance with local state or country regulations NOTE The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code NEC Article 600 SIGNXXX R071514 GE Lighting Solutions 1 888 MY GE LED www gelighting com 1 8 8 8 6 9 4 3 5 3 3 GE Lighting Solutions LLC is a subsidiary of the General Electric Company Tetra is a trademark of GE L...

Reviews: