background image

2 of 9 

P/N 1069682 • REV 1.0 • ISS 14APR10 

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this apparatus near water.

6) Clean only with a dry cloth.

7) Do not block any ventilation openings.

8) Install in accordance with the manufacturer’s instructions.

9) Do not install near any heat sources such as radiators, heat registers, stoves or other 
apparatus (including DVRs) that produce heat.

10) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug 
has two blades with one wider than the other. A grounding type plug has two blades and a
third grounding prong. The wider blade or the third prong are provided for your safety. If the 
provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet.

11) Protect the power cord from being walked on or pinched particularly at plugs, convenience 
receptacles, and the point where they exit from the apparatus.

12) Only use attachments/accessories specified by the manufacturer.

13) Unplug this apparatus during lightning storms or when unused for long periods of time.

14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus 
has been damaged in any way, such as a power supply cord or plug is damaged, liquid has 
been spilled, or objects have fallen into the apparatus, the apparatus has been exposed to 
rain or moisture, does not operate normally, or has been dropped.

         WARNING! - To reduce the risk of fire or electric shock, do not expose this apparatus to 
rain or moisture. This apparatus shall not be exposed to dripping or splashing and no objects 

filled with liquids, such as vases shall be placed on the apparatus.

       
         WARNING! -  This apparatus is a Class I product. This product must be connected to a 
mains socket outlet with a 

protective earthing connection.

        
          

The mains plug is used as the disconnect device and shall remain readily 

operable.

WARNING! - 

IMPORTANT SAFETY INSTRUCTIONS

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE
                   PARTS INSIDE. REFER SERVICING TO QUALIFIED
                   SERVICE PERSONNEL.

IMPORTANT SAFETY INSTRUCTIONS

        The exclamation point within an equilateral triangle, is intended to alert the user to the presence of important operating and 
maintenance instructions in the literature accompanying the appliance.

         The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated 
"dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

 

Summary of Contents for GEC-16VPHUB

Page 1: ...desk or rack mounted They use Category 2 7 twisted pair wires and do not require power They provide built in surge suppression to protect video equipment against damaging voltage spikes and provide noise immunity to ensure quality images The included RJ 45 adapter provides an easy way to connect the passive hubs to other GE VPD products via Cat 5 cables and RJ 45 connectors These passive hubs are ...

Page 2: ...as been damaged in any way such as a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture This apparatus shall not be exposed to dripping or splashing ...

Page 3: ...ivers Passive GE transceivers can transmit video and Up the Coax P T Z control signals up to 750 ft 228 m We recommend using short 18 AWG solid wires for ground connections GE VPD products follow the EIA TIA 568 standard There are two wire color code standards EIA TIA 568A and EIA TIA 568B Either standard can be used for making connections as long as the RJ 45 jacks at both ends of each cable foll...

Page 4: ... ft 14 m 90 ft 28 m 240 ft 73 m 1 AMP Camera Dual 23 AWG 58 ft 18 m 114 ft 35 m 300 ft 92 m Important Safety Warnings Installation should be made by a qualified service person and should conform to all local codes DO NOT bundle UTP signals in the same conduit as high voltage wiring To reduce the risk of fire or electrical shock do not expose these products to rain moisture dripping or splashing No...

Page 5: ...nnect to the transceiver hub Make sure that the same UTP pair and polarity are used on both the transmit and receive sides Video Connect the baseband Video signal output of the camera to the BNC of the Transceiver Control Room Installation UTP Connect the UTP wires carrying video signals to the terminal block input of the receiver hub If the UTP is terminated with a RJ 45 connector then use either...

Page 6: ...w connector to a qualified earth ground using a short thick wire If the picture is scrambled change the polarity of the twisted pair wires on the corresponding terminal block Technical Specifications Electrical Video Format NTSC PAL SECAM Frequency 20 Hz to 6 MHz Coax 75 Ohm Input Current 2 4 A at 115 VAC 1 2 A at 230 VAC GEC 8PVPDTCHUB 4 8 A at 110 VAC 2 4 A at 220 VAC GEC 16PVPDTCHUB Twisted Pai...

Page 7: ... 16VPHUB 17 x 1 74 x 3 in 43 x 4 2 x 7 6 cm GEC 32VPHUB 17 x 1 74 x 3 in 43 x 4 2 x 7 6 cm Weight GEC 4VPHUB 0 2 lb 90 g GEC 8VPHUB 3 3 lb 1500 g GEC 16VPHUB 3 3 lb 1500 g GEC 32VPHUB 3 3 lb 1500 g Environmental Humidity 0 to 95 noncondensing Temperature Operating 10 to 50 C Storage 30 to 70 C Specifications are subject to change without notice Included Accessories GEC 4VPHUB RJ 45 Adapter Include...

Page 8: ... 9 P N 1069682 REV 1 0 ISS 14APR10 EIA TIA 568A B Color Codes Midspan Control Room Data Connections GEC 4VPHUB Cameras 1 4 GEC 8VPHUB GEC 16VPHUB GEC 32VPHUB Cameras 1 8 GEC 16VPHUB GEC 32VPHUB Cameras 9 16 ...

Page 9: ... interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receive...

Reviews: