background image

2 of 11 

P/N 1069686 • REV 1.0 • ISS 10MAR10 

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this apparatus near water.

6) Clean only with a dry cloth.

7) Do not block any ventilation openings.

8) Install in accordance with the manufacturer’s instructions.

9) Do not install near any heat sources such as radiators, heat registers, stoves or other 
apparatus (including DVRs) that produce heat.

10) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug 
has two blades with one wider than the other. A grounding type plug has two blades and a
third grounding prong. The wider blade or the third prong are provided for your safety. If the 
provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet.

11) Protect the power cord from being walked on or pinched particularly at plugs, convenience 
receptacles, and the point where they exit from the apparatus.

12) Only use attachments/accessories specified by the manufacturer.

13) Unplug this apparatus during lightning storms or when unused for long periods of time.

14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus 
has been damaged in any way, such as a power supply cord or plug is damaged, liquid has 
been spilled, or objects have fallen into the apparatus, the apparatus has been exposed to 
rain or moisture, does not operate normally, or has been dropped.

         WARNING! - To reduce the risk of fire or electric shock, do not expose this apparatus to 
rain or moisture. This apparatus shall not be exposed to dripping or splashing and no objects 

filled with liquids, such as vases shall be placed on the apparatus.

       
         WARNING! -  This apparatus is a Class I product. This product must be connected to a 
mains socket outlet with a 

protective earthing connection.

        
          

The mains plug is used as the disconnect device and shall remain readily 

operable.

WARNING! - 

IMPORTANT SAFETY INSTRUCTIONS

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE
                   PARTS INSIDE. REFER SERVICING TO QUALIFIED
                   SERVICE PERSONNEL.

IMPORTANT SAFETY INSTRUCTIONS

        The exclamation point within an equilateral triangle, is intended to alert the user to the presence of important operating and 
maintenance instructions in the literature accompanying the appliance.

         The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated 
"dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

 

Summary of Contents for GEC-16PVPDTCHUB

Page 1: ...C 8PVPDTCHUB and GEC 16PVPDTCHUB come with built in 8 and 16 channel fully isolated class II 24 28 VAC power supplies Each camera power output in addition to an auto reset fuse is equipped with a 2 A glass fuse that is easily accessible from the front panel At the camera end a video balun combiner provides video power and data on separate outputs The video connections are through BNC connectors to...

Page 2: ...as been damaged in any way such as a power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture This apparatus shall not be exposed to dripping or splashing ...

Page 3: ...ivers Passive GE transceivers can transmit video and Up the Coax P T Z control signals up to 750 ft 228 m We recommend using short 18 AWG solid wires for ground connections GE VPD products follow the EIA TIA 568 standard There are two wire color code standards EIA TIA 568A and EIA TIA 568B Either standard can be used for making connections as long as the RJ 45 jacks at both ends of each cable foll...

Page 4: ...lation should be made by a qualified service person and should conform to all local codes DO NOT bundle UTP signals in the same conduit as high voltage wiring To reduce the risk of fire or electrical shock do not expose these products to rain moisture dripping or splashing No objects filled with liquids such as vases shall be placed on GE equipment DO NOT block ventilation openings to let sufficie...

Page 5: ...Connect the Data UTP pigtail Black White of the GE single combiner receiver to the data connector of the camera There is no data connection on GEC VCR Power Connect the power UTP pigtail Black Red of the GE single combiner receiver to the power connector of the camera Leave this power cable unconnected for PTZ dome cameras Cat 5 Cable Connect the RJ 45 connector attached to the camera end of Cat 5...

Page 6: ...ceiver unit Video Use provided 2 ft 60 cm coax patch cords to connect the BNC video inputs of video receiving devices such as DVRs or matrix switches Data Connect each RJ 45 data connector to a Cat 5 cable carrying 4 data signals to the PTZ controller In starting a configuration use a data distribution unit to populate the single data line from DVR Then run the outputs of the data distributor to R...

Page 7: ...Mid span location closer to the cameras Use an active receiver hub at control room Step 3 Use a single channel GE combiner transceiver on the camera side considering the camera voltage Diagnostic LEDs GEC 4VDPBC GEC 16VDPBC There is one green LED per channel OFF Camera power is disconnected ON Camera is connected and current flows GEC 8PVPDTCHUB GEC 16PVPDTCHUB There are two diagnostic LEDs per ch...

Page 8: ...ult Protection 2 A 5x20 mm type T fuse front access plus a 2 5 A self resetting fuse at per channel Main fuse 4 A at 115 VAC 3 A at 220 VAC 5x20 mm GEC 8PVPDTCHUB 7 A at 115 VAC 5 A at 220 VAC 5x20 mm GEC 16PVPDTCHUB Twisted Pair 100 Ohms 20 24 AWG minimum Category 2 7 Connectors Camera connection RJ 45 connector Data RJ 45 connector Video BNC connector Power Screw less connector GEC 4VDPBC GEC 16...

Page 9: ...noncondensing Temperature Operating 10 to 50 C Storage 30 to 70 C Specifications are subject to change without notice Included Accessories Mounting brackets for front rear or wall installations Rubber feet for desk applications 8 or 16 2 ft 60 cm coax jumper cables excluding GEC 4VDPBC RJ 45 Adapters excluding GEC 4VDPBC Molded IEC power inlet cord 7 ft 200 cm EIA TIA 568A B Color Codes ...

Page 10: ... 1069686 REV 1 0 ISS 10MAR10 Camera side RJ 45 Connections Control Room Data Connections Figure 2 GEC 4VDPBC Cameras 1 4 only 16VDPBC 8PVPDTCHUB 16PVPDTCHUB Cameras 1 8 Figure 3 GEC 16VDPBC 16PVPDTCHUB Cameras 9 16 ...

Page 11: ...However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation...

Reviews: