GE GE Monogram ZVB30BN Dimensions And Installation Information Download Page 3

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

130677

Specification Created 11/08

Listed by 

Underwriters 

Laboratories

ZVB30SN/BN

GE Monogram

® 

30" Telescopic Downdraft Vents

Dimensions and Installation Information (in inches) 

Venting Options

The downdraft vent is shipped with the discharge outlet 

pointing straight down and can be changed to a left- or 

right-side discharge. For even more flexibility, the entire 

blower and mounting plate can be adjusted 3-1/2" to the 

left or right sides.

Electrical and Gas Locations

Plan the placement of the electrical outlet and gas (if used) 

carefully. Gas or electrical outlets cannot be located on the 

back wall of the cabinet because they may interfere with the 

downdraft plenum.
•  Install a standard electrical outlet within reach of the 

vent’s two-foot-long power cord. Locate the outlet inside 

the cabinet on the right side wall. 

•  If the vent is installed in combination with a Monogram

®

  

gas cooktop, it may operate from the same 120V standard  

duplex outlet.

•  If the vent is installed in combination with a Monogram 

electric cooktop, the vent must operate from a separate 

120V outlet.

34" for 36" Models

28-1/2" for 30" Models

29-1/2"

Electrical

Outlet

12" Above

Cabinet Floor

Do Not Locate Gas or Electrical

Connections Within Shaded Area

682Dia47

Summary of Contents for GE Monogram ZVB30BN

Page 1: ...n For accurate planning review the individual dimension drawings for the combined vent and Monogram cooktop installation Before you begin you must 1 Review countertop dimension illustrations to be sure you will have enough flat countertop surface depth 2 Check to be sure that the total countertop depth required including minimum cutout to front edge depth allows enough space for a backsplash 3 Rev...

Page 2: ...anel Base Sink Filler Panel Maintain Cutout Clearances to Front Edge as Specified 605Dia160 Cover Panel Base Sink End Panel Countertop Overhang per Cooktop Clearances Must be Maintained 605Dia161 DOWNDRAFT VENT 1 7 8 Trim Add a Bullnose Trim or Decorative Molding to Increase Countertop Depth and to Maintain Required Clearance From Front Edge Optional Accessories JXRB67 Accessory for indoor remote ...

Page 3: ...ctrical and Gas Locations Plan the placement of the electrical outlet and gas if used carefully Gas or electrical outlets cannot be located on the back wall of the cabinet because they may interfere with the downdraft plenum Install a standard electrical outlet within reach of the vent s two foot long power cord Locate the outlet inside the cabinet on the right side wall If the vent is installed i...

Page 4: ... When You Cook Then Retracts When Not in Use 500 CFM Performance Helps Keep Your Kitchen Free of Fumes and Excess Heat Remote Mounted Control Provides Design Flexibility Variable Speed Blower with Electronic Controls Complements Most Monogram Cooktops Removable Grease Filters Trap Airborne Grease Particles Optional Remote Blower Capabilities Stainless Steel Vent Body Offers a Smooth and Polished A...

Reviews: